Cargando…

3D Maps of Mineral Composition and Hydroxyapatite Orientation in Fossil Bone Samples Obtained by X-ray Diffraction Computed Tomography

Whether hydroxyapatite (HA) orientation in fossilised bone samples can be non-destructively retrieved and used to determine the arrangement of the bone matrix and the location of muscle attachments (entheses), is a question of high relevance to palaeontology, as it facilitates a detailed understandi...

Descripción completa

Detalles Bibliográficos
Autores principales: Mürer, Fredrik K., Sanchez, Sophie, Álvarez-Murga, Michelle, Di Michiel, Marco, Pfeiffer, Franz, Bech, Martin, Breiby, Dag W.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6030225/
https://www.ncbi.nlm.nih.gov/pubmed/29968761
http://dx.doi.org/10.1038/s41598-018-28269-1
_version_ 1783337103200878592
author Mürer, Fredrik K.
Sanchez, Sophie
Álvarez-Murga, Michelle
Di Michiel, Marco
Pfeiffer, Franz
Bech, Martin
Breiby, Dag W.
author_facet Mürer, Fredrik K.
Sanchez, Sophie
Álvarez-Murga, Michelle
Di Michiel, Marco
Pfeiffer, Franz
Bech, Martin
Breiby, Dag W.
author_sort Mürer, Fredrik K.
collection PubMed
description Whether hydroxyapatite (HA) orientation in fossilised bone samples can be non-destructively retrieved and used to determine the arrangement of the bone matrix and the location of muscle attachments (entheses), is a question of high relevance to palaeontology, as it facilitates a detailed understanding of the (micro-)anatomy of extinct species with no damage to the precious fossil specimens. Here, we report studies of two fossil bone samples, specifically the tibia of a 300-million-year-old tetrapod, Discosauriscus austriacus, and the humerus of a 370-million-year-old lobe-finned fish, Eusthenopteron foordi, using XRD-CT – a combination of X-ray diffraction (XRD) and computed tomography (CT). Reconstructed 3D images showing the spatial mineral distributions and the local orientation of HA were obtained. For Discosauriscus austriacus, details of the muscle attachments could be discerned. For Eusthenopteron foordi, the gross details of the preferred orientation of HA were deduced using three tomographic datasets obtained with orthogonally oriented rotation axes. For both samples, the HA in the bone matrix exhibited preferred orientation, with the unit cell c-axis of the HA crystallites tending to be parallel with the bone surface. In summary, we have demonstrated that XRD-CT combined with an intuitive reconstruction procedure is becoming a powerful tool for studying palaeontological samples.
format Online
Article
Text
id pubmed-6030225
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-60302252018-07-11 3D Maps of Mineral Composition and Hydroxyapatite Orientation in Fossil Bone Samples Obtained by X-ray Diffraction Computed Tomography Mürer, Fredrik K. Sanchez, Sophie Álvarez-Murga, Michelle Di Michiel, Marco Pfeiffer, Franz Bech, Martin Breiby, Dag W. Sci Rep Article Whether hydroxyapatite (HA) orientation in fossilised bone samples can be non-destructively retrieved and used to determine the arrangement of the bone matrix and the location of muscle attachments (entheses), is a question of high relevance to palaeontology, as it facilitates a detailed understanding of the (micro-)anatomy of extinct species with no damage to the precious fossil specimens. Here, we report studies of two fossil bone samples, specifically the tibia of a 300-million-year-old tetrapod, Discosauriscus austriacus, and the humerus of a 370-million-year-old lobe-finned fish, Eusthenopteron foordi, using XRD-CT – a combination of X-ray diffraction (XRD) and computed tomography (CT). Reconstructed 3D images showing the spatial mineral distributions and the local orientation of HA were obtained. For Discosauriscus austriacus, details of the muscle attachments could be discerned. For Eusthenopteron foordi, the gross details of the preferred orientation of HA were deduced using three tomographic datasets obtained with orthogonally oriented rotation axes. For both samples, the HA in the bone matrix exhibited preferred orientation, with the unit cell c-axis of the HA crystallites tending to be parallel with the bone surface. In summary, we have demonstrated that XRD-CT combined with an intuitive reconstruction procedure is becoming a powerful tool for studying palaeontological samples. Nature Publishing Group UK 2018-07-03 /pmc/articles/PMC6030225/ /pubmed/29968761 http://dx.doi.org/10.1038/s41598-018-28269-1 Text en © The Author(s) 2018 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Article
Mürer, Fredrik K.
Sanchez, Sophie
Álvarez-Murga, Michelle
Di Michiel, Marco
Pfeiffer, Franz
Bech, Martin
Breiby, Dag W.
3D Maps of Mineral Composition and Hydroxyapatite Orientation in Fossil Bone Samples Obtained by X-ray Diffraction Computed Tomography
title 3D Maps of Mineral Composition and Hydroxyapatite Orientation in Fossil Bone Samples Obtained by X-ray Diffraction Computed Tomography
title_full 3D Maps of Mineral Composition and Hydroxyapatite Orientation in Fossil Bone Samples Obtained by X-ray Diffraction Computed Tomography
title_fullStr 3D Maps of Mineral Composition and Hydroxyapatite Orientation in Fossil Bone Samples Obtained by X-ray Diffraction Computed Tomography
title_full_unstemmed 3D Maps of Mineral Composition and Hydroxyapatite Orientation in Fossil Bone Samples Obtained by X-ray Diffraction Computed Tomography
title_short 3D Maps of Mineral Composition and Hydroxyapatite Orientation in Fossil Bone Samples Obtained by X-ray Diffraction Computed Tomography
title_sort 3d maps of mineral composition and hydroxyapatite orientation in fossil bone samples obtained by x-ray diffraction computed tomography
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6030225/
https://www.ncbi.nlm.nih.gov/pubmed/29968761
http://dx.doi.org/10.1038/s41598-018-28269-1
work_keys_str_mv AT murerfredrikk 3dmapsofmineralcompositionandhydroxyapatiteorientationinfossilbonesamplesobtainedbyxraydiffractioncomputedtomography
AT sanchezsophie 3dmapsofmineralcompositionandhydroxyapatiteorientationinfossilbonesamplesobtainedbyxraydiffractioncomputedtomography
AT alvarezmurgamichelle 3dmapsofmineralcompositionandhydroxyapatiteorientationinfossilbonesamplesobtainedbyxraydiffractioncomputedtomography
AT dimichielmarco 3dmapsofmineralcompositionandhydroxyapatiteorientationinfossilbonesamplesobtainedbyxraydiffractioncomputedtomography
AT pfeifferfranz 3dmapsofmineralcompositionandhydroxyapatiteorientationinfossilbonesamplesobtainedbyxraydiffractioncomputedtomography
AT bechmartin 3dmapsofmineralcompositionandhydroxyapatiteorientationinfossilbonesamplesobtainedbyxraydiffractioncomputedtomography
AT breibydagw 3dmapsofmineralcompositionandhydroxyapatiteorientationinfossilbonesamplesobtainedbyxraydiffractioncomputedtomography