Cargando…
3D Maps of Mineral Composition and Hydroxyapatite Orientation in Fossil Bone Samples Obtained by X-ray Diffraction Computed Tomography
Whether hydroxyapatite (HA) orientation in fossilised bone samples can be non-destructively retrieved and used to determine the arrangement of the bone matrix and the location of muscle attachments (entheses), is a question of high relevance to palaeontology, as it facilitates a detailed understandi...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6030225/ https://www.ncbi.nlm.nih.gov/pubmed/29968761 http://dx.doi.org/10.1038/s41598-018-28269-1 |
_version_ | 1783337103200878592 |
---|---|
author | Mürer, Fredrik K. Sanchez, Sophie Álvarez-Murga, Michelle Di Michiel, Marco Pfeiffer, Franz Bech, Martin Breiby, Dag W. |
author_facet | Mürer, Fredrik K. Sanchez, Sophie Álvarez-Murga, Michelle Di Michiel, Marco Pfeiffer, Franz Bech, Martin Breiby, Dag W. |
author_sort | Mürer, Fredrik K. |
collection | PubMed |
description | Whether hydroxyapatite (HA) orientation in fossilised bone samples can be non-destructively retrieved and used to determine the arrangement of the bone matrix and the location of muscle attachments (entheses), is a question of high relevance to palaeontology, as it facilitates a detailed understanding of the (micro-)anatomy of extinct species with no damage to the precious fossil specimens. Here, we report studies of two fossil bone samples, specifically the tibia of a 300-million-year-old tetrapod, Discosauriscus austriacus, and the humerus of a 370-million-year-old lobe-finned fish, Eusthenopteron foordi, using XRD-CT – a combination of X-ray diffraction (XRD) and computed tomography (CT). Reconstructed 3D images showing the spatial mineral distributions and the local orientation of HA were obtained. For Discosauriscus austriacus, details of the muscle attachments could be discerned. For Eusthenopteron foordi, the gross details of the preferred orientation of HA were deduced using three tomographic datasets obtained with orthogonally oriented rotation axes. For both samples, the HA in the bone matrix exhibited preferred orientation, with the unit cell c-axis of the HA crystallites tending to be parallel with the bone surface. In summary, we have demonstrated that XRD-CT combined with an intuitive reconstruction procedure is becoming a powerful tool for studying palaeontological samples. |
format | Online Article Text |
id | pubmed-6030225 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-60302252018-07-11 3D Maps of Mineral Composition and Hydroxyapatite Orientation in Fossil Bone Samples Obtained by X-ray Diffraction Computed Tomography Mürer, Fredrik K. Sanchez, Sophie Álvarez-Murga, Michelle Di Michiel, Marco Pfeiffer, Franz Bech, Martin Breiby, Dag W. Sci Rep Article Whether hydroxyapatite (HA) orientation in fossilised bone samples can be non-destructively retrieved and used to determine the arrangement of the bone matrix and the location of muscle attachments (entheses), is a question of high relevance to palaeontology, as it facilitates a detailed understanding of the (micro-)anatomy of extinct species with no damage to the precious fossil specimens. Here, we report studies of two fossil bone samples, specifically the tibia of a 300-million-year-old tetrapod, Discosauriscus austriacus, and the humerus of a 370-million-year-old lobe-finned fish, Eusthenopteron foordi, using XRD-CT – a combination of X-ray diffraction (XRD) and computed tomography (CT). Reconstructed 3D images showing the spatial mineral distributions and the local orientation of HA were obtained. For Discosauriscus austriacus, details of the muscle attachments could be discerned. For Eusthenopteron foordi, the gross details of the preferred orientation of HA were deduced using three tomographic datasets obtained with orthogonally oriented rotation axes. For both samples, the HA in the bone matrix exhibited preferred orientation, with the unit cell c-axis of the HA crystallites tending to be parallel with the bone surface. In summary, we have demonstrated that XRD-CT combined with an intuitive reconstruction procedure is becoming a powerful tool for studying palaeontological samples. Nature Publishing Group UK 2018-07-03 /pmc/articles/PMC6030225/ /pubmed/29968761 http://dx.doi.org/10.1038/s41598-018-28269-1 Text en © The Author(s) 2018 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Article Mürer, Fredrik K. Sanchez, Sophie Álvarez-Murga, Michelle Di Michiel, Marco Pfeiffer, Franz Bech, Martin Breiby, Dag W. 3D Maps of Mineral Composition and Hydroxyapatite Orientation in Fossil Bone Samples Obtained by X-ray Diffraction Computed Tomography |
title | 3D Maps of Mineral Composition and Hydroxyapatite Orientation in Fossil Bone Samples Obtained by X-ray Diffraction Computed Tomography |
title_full | 3D Maps of Mineral Composition and Hydroxyapatite Orientation in Fossil Bone Samples Obtained by X-ray Diffraction Computed Tomography |
title_fullStr | 3D Maps of Mineral Composition and Hydroxyapatite Orientation in Fossil Bone Samples Obtained by X-ray Diffraction Computed Tomography |
title_full_unstemmed | 3D Maps of Mineral Composition and Hydroxyapatite Orientation in Fossil Bone Samples Obtained by X-ray Diffraction Computed Tomography |
title_short | 3D Maps of Mineral Composition and Hydroxyapatite Orientation in Fossil Bone Samples Obtained by X-ray Diffraction Computed Tomography |
title_sort | 3d maps of mineral composition and hydroxyapatite orientation in fossil bone samples obtained by x-ray diffraction computed tomography |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6030225/ https://www.ncbi.nlm.nih.gov/pubmed/29968761 http://dx.doi.org/10.1038/s41598-018-28269-1 |
work_keys_str_mv | AT murerfredrikk 3dmapsofmineralcompositionandhydroxyapatiteorientationinfossilbonesamplesobtainedbyxraydiffractioncomputedtomography AT sanchezsophie 3dmapsofmineralcompositionandhydroxyapatiteorientationinfossilbonesamplesobtainedbyxraydiffractioncomputedtomography AT alvarezmurgamichelle 3dmapsofmineralcompositionandhydroxyapatiteorientationinfossilbonesamplesobtainedbyxraydiffractioncomputedtomography AT dimichielmarco 3dmapsofmineralcompositionandhydroxyapatiteorientationinfossilbonesamplesobtainedbyxraydiffractioncomputedtomography AT pfeifferfranz 3dmapsofmineralcompositionandhydroxyapatiteorientationinfossilbonesamplesobtainedbyxraydiffractioncomputedtomography AT bechmartin 3dmapsofmineralcompositionandhydroxyapatiteorientationinfossilbonesamplesobtainedbyxraydiffractioncomputedtomography AT breibydagw 3dmapsofmineralcompositionandhydroxyapatiteorientationinfossilbonesamplesobtainedbyxraydiffractioncomputedtomography |