Cargando…

Evaluator Training and Reliability for SMA Global Nusinersen Trials(1)

BACKGROUND: Training methodology was established to optimize reliability of outcome measures in the nusinersen clinical trials. The Children’s Hospital of Philadelphia Infant Test of Neuromuscular Disorders (CHOP INTEND), Hammersmith Functional Motor Scale Expanded (HFMSE), and Revised Upper Limb (R...

Descripción completa

Detalles Bibliográficos
Autores principales: Glanzman, Allan M., Mazzone, Elena S., Young, Sally Dunaway, Gee, Richard, Rose, Kristy, Mayhew, Anna, Nelson, Leslie, Yun, Chris, Alexander, Katie, Darras, Basil T., Zolkipli-Cunningham, Zarazuela, Tennekoon, Gihan, Day, John W., Finkel, Richard S., Mercuri, Eugenio, De Vivo, Darryl C., Baldwin, Ron, Bishop, Kathie M., Montes, Jacqueline
Formato: Online Artículo Texto
Lenguaje:English
Publicado: IOS Press 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6030668/
https://www.ncbi.nlm.nih.gov/pubmed/29865090
http://dx.doi.org/10.3233/JND-180301
_version_ 1783337175167795200
author Glanzman, Allan M.
Mazzone, Elena S.
Young, Sally Dunaway
Gee, Richard
Rose, Kristy
Mayhew, Anna
Nelson, Leslie
Yun, Chris
Alexander, Katie
Darras, Basil T.
Zolkipli-Cunningham, Zarazuela
Tennekoon, Gihan
Day, John W.
Finkel, Richard S.
Mercuri, Eugenio
De Vivo, Darryl C.
Baldwin, Ron
Bishop, Kathie M.
Montes, Jacqueline
author_facet Glanzman, Allan M.
Mazzone, Elena S.
Young, Sally Dunaway
Gee, Richard
Rose, Kristy
Mayhew, Anna
Nelson, Leslie
Yun, Chris
Alexander, Katie
Darras, Basil T.
Zolkipli-Cunningham, Zarazuela
Tennekoon, Gihan
Day, John W.
Finkel, Richard S.
Mercuri, Eugenio
De Vivo, Darryl C.
Baldwin, Ron
Bishop, Kathie M.
Montes, Jacqueline
author_sort Glanzman, Allan M.
collection PubMed
description BACKGROUND: Training methodology was established to optimize reliability of outcome measures in the nusinersen clinical trials. The Children’s Hospital of Philadelphia Infant Test of Neuromuscular Disorders (CHOP INTEND), Hammersmith Functional Motor Scale Expanded (HFMSE), and Revised Upper Limb (RULM) were primary or secondary outcomes. METHODS: Video review, quarterly conference calls, and item scoring checks supported evaluator competence. Baseline and screening along with video review established intra and inter-rater reliability. RESULTS: Inter and intra-rater reliability were both excellent. Intraclass correlation coefficients (ICC) ranged between 0.906–0.994 across initial training meetings and 0.824–0.996 across annual retraining meetings. This was similar for CHOP INTEND (ICC = 0.824–0.951), HFMSE (ICC = 0.981–0.996), and RULM (ICC = 0.966–0.990). Intra-rater reliability for the CHOP INTEND, HFMSE, and RULM were ICC = 0.895 (95% CI: 0.852–0.926; n = 116), ICC = 0.959 (95% CI: 0.942–0.971; n = 125), and ICC = 0.948 (95% CI: 0.927–0.963; n = 126) respectively. CONCLUSIONS: Rigorous evaluator training ensures reliability of assessment of subjects with spinal muscular atrophy (SMA) in multicenter international trials.
format Online
Article
Text
id pubmed-6030668
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher IOS Press
record_format MEDLINE/PubMed
spelling pubmed-60306682018-07-05 Evaluator Training and Reliability for SMA Global Nusinersen Trials(1) Glanzman, Allan M. Mazzone, Elena S. Young, Sally Dunaway Gee, Richard Rose, Kristy Mayhew, Anna Nelson, Leslie Yun, Chris Alexander, Katie Darras, Basil T. Zolkipli-Cunningham, Zarazuela Tennekoon, Gihan Day, John W. Finkel, Richard S. Mercuri, Eugenio De Vivo, Darryl C. Baldwin, Ron Bishop, Kathie M. Montes, Jacqueline J Neuromuscul Dis Research Report BACKGROUND: Training methodology was established to optimize reliability of outcome measures in the nusinersen clinical trials. The Children’s Hospital of Philadelphia Infant Test of Neuromuscular Disorders (CHOP INTEND), Hammersmith Functional Motor Scale Expanded (HFMSE), and Revised Upper Limb (RULM) were primary or secondary outcomes. METHODS: Video review, quarterly conference calls, and item scoring checks supported evaluator competence. Baseline and screening along with video review established intra and inter-rater reliability. RESULTS: Inter and intra-rater reliability were both excellent. Intraclass correlation coefficients (ICC) ranged between 0.906–0.994 across initial training meetings and 0.824–0.996 across annual retraining meetings. This was similar for CHOP INTEND (ICC = 0.824–0.951), HFMSE (ICC = 0.981–0.996), and RULM (ICC = 0.966–0.990). Intra-rater reliability for the CHOP INTEND, HFMSE, and RULM were ICC = 0.895 (95% CI: 0.852–0.926; n = 116), ICC = 0.959 (95% CI: 0.942–0.971; n = 125), and ICC = 0.948 (95% CI: 0.927–0.963; n = 126) respectively. CONCLUSIONS: Rigorous evaluator training ensures reliability of assessment of subjects with spinal muscular atrophy (SMA) in multicenter international trials. IOS Press 2018-05-29 /pmc/articles/PMC6030668/ /pubmed/29865090 http://dx.doi.org/10.3233/JND-180301 Text en © 2018 – IOS Press and the authors. All rights reserved https://creativecommons.org/licenses/by-nc/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution Non-Commercial (CC BY-NC 4.0) License (https://creativecommons.org/licenses/by-nc/4.0/) , which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Report
Glanzman, Allan M.
Mazzone, Elena S.
Young, Sally Dunaway
Gee, Richard
Rose, Kristy
Mayhew, Anna
Nelson, Leslie
Yun, Chris
Alexander, Katie
Darras, Basil T.
Zolkipli-Cunningham, Zarazuela
Tennekoon, Gihan
Day, John W.
Finkel, Richard S.
Mercuri, Eugenio
De Vivo, Darryl C.
Baldwin, Ron
Bishop, Kathie M.
Montes, Jacqueline
Evaluator Training and Reliability for SMA Global Nusinersen Trials(1)
title Evaluator Training and Reliability for SMA Global Nusinersen Trials(1)
title_full Evaluator Training and Reliability for SMA Global Nusinersen Trials(1)
title_fullStr Evaluator Training and Reliability for SMA Global Nusinersen Trials(1)
title_full_unstemmed Evaluator Training and Reliability for SMA Global Nusinersen Trials(1)
title_short Evaluator Training and Reliability for SMA Global Nusinersen Trials(1)
title_sort evaluator training and reliability for sma global nusinersen trials(1)
topic Research Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6030668/
https://www.ncbi.nlm.nih.gov/pubmed/29865090
http://dx.doi.org/10.3233/JND-180301
work_keys_str_mv AT glanzmanallanm evaluatortrainingandreliabilityforsmaglobalnusinersentrials1
AT mazzoneelenas evaluatortrainingandreliabilityforsmaglobalnusinersentrials1
AT youngsallydunaway evaluatortrainingandreliabilityforsmaglobalnusinersentrials1
AT geerichard evaluatortrainingandreliabilityforsmaglobalnusinersentrials1
AT rosekristy evaluatortrainingandreliabilityforsmaglobalnusinersentrials1
AT mayhewanna evaluatortrainingandreliabilityforsmaglobalnusinersentrials1
AT nelsonleslie evaluatortrainingandreliabilityforsmaglobalnusinersentrials1
AT yunchris evaluatortrainingandreliabilityforsmaglobalnusinersentrials1
AT alexanderkatie evaluatortrainingandreliabilityforsmaglobalnusinersentrials1
AT darrasbasilt evaluatortrainingandreliabilityforsmaglobalnusinersentrials1
AT zolkiplicunninghamzarazuela evaluatortrainingandreliabilityforsmaglobalnusinersentrials1
AT tennekoongihan evaluatortrainingandreliabilityforsmaglobalnusinersentrials1
AT dayjohnw evaluatortrainingandreliabilityforsmaglobalnusinersentrials1
AT finkelrichards evaluatortrainingandreliabilityforsmaglobalnusinersentrials1
AT mercurieugenio evaluatortrainingandreliabilityforsmaglobalnusinersentrials1
AT devivodarrylc evaluatortrainingandreliabilityforsmaglobalnusinersentrials1
AT baldwinron evaluatortrainingandreliabilityforsmaglobalnusinersentrials1
AT bishopkathiem evaluatortrainingandreliabilityforsmaglobalnusinersentrials1
AT montesjacqueline evaluatortrainingandreliabilityforsmaglobalnusinersentrials1