Method for measuring extracellular flux from intact polarized epithelial monolayers

PURPOSE: The Seahorse XFp platform is widely used for metabolic assessment of cultured cells. Current methods require replating of cells into specialized plates. This is problematic for certain cell types, such as primary human fetal RPE (hfRPE) cells, which must be cultured for months to become pro...

Descripción completa

Detalles Bibliográficos
Autores principales: Calton, Melissa A., Beaulieu, Marielle O., Benchorin, Gillie, Vollrath, Douglas
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Molecular Vision 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6031101/
https://www.ncbi.nlm.nih.gov/pubmed/30034209
_version_ 1783337253643223040
author Calton, Melissa A.
Beaulieu, Marielle O.
Benchorin, Gillie
Vollrath, Douglas
author_facet Calton, Melissa A.
Beaulieu, Marielle O.
Benchorin, Gillie
Vollrath, Douglas
author_sort Calton, Melissa A.
collection PubMed
description PURPOSE: The Seahorse XFp platform is widely used for metabolic assessment of cultured cells. Current methods require replating of cells into specialized plates. This is problematic for certain cell types, such as primary human fetal RPE (hfRPE) cells, which must be cultured for months to become properly differentiated. Our goal was to overcome this limitation by devising a method for assaying intact cell monolayers with the Seahorse XFp, without the need for replating. METHODS: Primary hfRPE cells were differentiated by prolonged culture on filter inserts. Triangular sections of filters with differentiated cells attached were excised, transferred to XFp cell culture miniplate wells, immobilized at the bottoms, and subjected to mitochondrial stress tests. Replated cells were measured for comparison. Differentiated hfRPE cells were challenged or not with bovine photoreceptor outer segments (POS), and mitochondrial stress tests were performed 3.5 h later, after filter excision and transfer to assay plates. RESULTS: Differentiated hfRPE cells assayed following filter excision demonstrated increased maximal respiration, increased spare respiration capacity, and increased extracellular acidification rate (ECAR) relative to replated controls. hfRPE cells challenged with POS exhibited increased maximal respiration and spare capacity, with no apparent change in the ECAR, relative to untreated controls. CONCLUSIONS: We have developed a method to reproducibly assay intact, polarized monolayers of hfRPE cells with the Seahorse XFp platform and have shown that the method yields more robust metabolic measurements compared to standard methods and is suitable for assessing the consequences of prolonged perturbations of differentiated cells. We expect our approach to be useful for a variety of studies involving metabolic assessment of adherent cells cultured on filters.
format Online
Article
Text
id pubmed-6031101
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Molecular Vision
record_format MEDLINE/PubMed
spelling pubmed-60311012018-07-20 Method for measuring extracellular flux from intact polarized epithelial monolayers Calton, Melissa A. Beaulieu, Marielle O. Benchorin, Gillie Vollrath, Douglas Mol Vis Research Article PURPOSE: The Seahorse XFp platform is widely used for metabolic assessment of cultured cells. Current methods require replating of cells into specialized plates. This is problematic for certain cell types, such as primary human fetal RPE (hfRPE) cells, which must be cultured for months to become properly differentiated. Our goal was to overcome this limitation by devising a method for assaying intact cell monolayers with the Seahorse XFp, without the need for replating. METHODS: Primary hfRPE cells were differentiated by prolonged culture on filter inserts. Triangular sections of filters with differentiated cells attached were excised, transferred to XFp cell culture miniplate wells, immobilized at the bottoms, and subjected to mitochondrial stress tests. Replated cells were measured for comparison. Differentiated hfRPE cells were challenged or not with bovine photoreceptor outer segments (POS), and mitochondrial stress tests were performed 3.5 h later, after filter excision and transfer to assay plates. RESULTS: Differentiated hfRPE cells assayed following filter excision demonstrated increased maximal respiration, increased spare respiration capacity, and increased extracellular acidification rate (ECAR) relative to replated controls. hfRPE cells challenged with POS exhibited increased maximal respiration and spare capacity, with no apparent change in the ECAR, relative to untreated controls. CONCLUSIONS: We have developed a method to reproducibly assay intact, polarized monolayers of hfRPE cells with the Seahorse XFp platform and have shown that the method yields more robust metabolic measurements compared to standard methods and is suitable for assessing the consequences of prolonged perturbations of differentiated cells. We expect our approach to be useful for a variety of studies involving metabolic assessment of adherent cells cultured on filters. Molecular Vision 2018-06-25 /pmc/articles/PMC6031101/ /pubmed/30034209 Text en Copyright © 2018 Molecular Vision. http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited, used for non-commercial purposes, and is not altered or transformed.
spellingShingle Research Article
Calton, Melissa A.
Beaulieu, Marielle O.
Benchorin, Gillie
Vollrath, Douglas
Method for measuring extracellular flux from intact polarized epithelial monolayers
title Method for measuring extracellular flux from intact polarized epithelial monolayers
title_full Method for measuring extracellular flux from intact polarized epithelial monolayers
title_fullStr Method for measuring extracellular flux from intact polarized epithelial monolayers
title_full_unstemmed Method for measuring extracellular flux from intact polarized epithelial monolayers
title_short Method for measuring extracellular flux from intact polarized epithelial monolayers
title_sort method for measuring extracellular flux from intact polarized epithelial monolayers
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6031101/
https://www.ncbi.nlm.nih.gov/pubmed/30034209
work_keys_str_mv AT caltonmelissaa methodformeasuringextracellularfluxfromintactpolarizedepithelialmonolayers
AT beaulieumarielleo methodformeasuringextracellularfluxfromintactpolarizedepithelialmonolayers
AT benchoringillie methodformeasuringextracellularfluxfromintactpolarizedepithelialmonolayers
AT vollrathdouglas methodformeasuringextracellularfluxfromintactpolarizedepithelialmonolayers