The BeGraft Balloon Expandable Covered Stent as a Proximal Extension to an Iliac Branch Device for Endovascular Repair of Isolated Common Iliac Artery Aneurysms

INTRODUCTION: Isolated common iliac artery aneurysms (CIAA) are rare and can be treated by endovascular exclusion using iliac branch devices (IBD). The use of a balloon expandable covered stent as a proximal extension to an IBD to allow adequate sealing in the proximal common iliac artery (CIA) for...

Descripción completa

Detalles Bibliográficos
Autores principales: Vos, Cornelis G., Schuurmann, Richte C.L., de Vries, Jean-Paul P.M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6033046/
https://www.ncbi.nlm.nih.gov/pubmed/29988832
http://dx.doi.org/10.1016/j.ejvssr.2018.03.002
_version_ 1783337624629411840
author Vos, Cornelis G.
Schuurmann, Richte C.L.
de Vries, Jean-Paul P.M.
author_facet Vos, Cornelis G.
Schuurmann, Richte C.L.
de Vries, Jean-Paul P.M.
author_sort Vos, Cornelis G.
collection PubMed
description INTRODUCTION: Isolated common iliac artery aneurysms (CIAA) are rare and can be treated by endovascular exclusion using iliac branch devices (IBD). The use of a balloon expandable covered stent as a proximal extension to an IBD to allow adequate sealing in the proximal common iliac artery (CIA) for exclusion of isolated CIAA is demonstrated. REPORT: Two patients with isolated CIAA of ≥4.5 cm with a proximal neck length of ≥20 mm (patient A: 26 mm; patient B: 24 mm) and a neck diameter of ≤20 mm (patient A: 16.4 mm; patient B: 15.6 mm) were treated by combining a Zenith IBD with an aortic BeGraft balloon expandable covered stent. After deploying the BeGraft covered stent at 12 mm a second balloon was used to further dilate the proximal part of the stent outside the IBD to allow adequate sealing in the CIA. Completion angiography and follow up computed tomography angiography 1 month post-operatively showed adequate sealing and no endoleaks. DISCUSSION: The feasibility of the application of a balloon expandable covered stent as a proximal extension to an IBD for isolated CIAA was demonstrated. It is not necessary to insert an aortic bifurcation endograft, thus reducing procedure time, radiation exposure, contrast use, and cost. A patent inferior mesenteric artery and lumbar arteries can be spared and procedures that require crossing over the aortic bifurcation remain possible. Comorbidity, prior interventions, and disease extension can make this endovascular approach preferred over open repair. Isolated CIAA can be efficiently treated combining the BeGraft balloon expandable covered stent and IBD, which allows proximal sealing in the CIA.
format Online
Article
Text
id pubmed-6033046
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-60330462018-07-09 The BeGraft Balloon Expandable Covered Stent as a Proximal Extension to an Iliac Branch Device for Endovascular Repair of Isolated Common Iliac Artery Aneurysms Vos, Cornelis G. Schuurmann, Richte C.L. de Vries, Jean-Paul P.M. EJVES Short Rep Case Report INTRODUCTION: Isolated common iliac artery aneurysms (CIAA) are rare and can be treated by endovascular exclusion using iliac branch devices (IBD). The use of a balloon expandable covered stent as a proximal extension to an IBD to allow adequate sealing in the proximal common iliac artery (CIA) for exclusion of isolated CIAA is demonstrated. REPORT: Two patients with isolated CIAA of ≥4.5 cm with a proximal neck length of ≥20 mm (patient A: 26 mm; patient B: 24 mm) and a neck diameter of ≤20 mm (patient A: 16.4 mm; patient B: 15.6 mm) were treated by combining a Zenith IBD with an aortic BeGraft balloon expandable covered stent. After deploying the BeGraft covered stent at 12 mm a second balloon was used to further dilate the proximal part of the stent outside the IBD to allow adequate sealing in the CIA. Completion angiography and follow up computed tomography angiography 1 month post-operatively showed adequate sealing and no endoleaks. DISCUSSION: The feasibility of the application of a balloon expandable covered stent as a proximal extension to an IBD for isolated CIAA was demonstrated. It is not necessary to insert an aortic bifurcation endograft, thus reducing procedure time, radiation exposure, contrast use, and cost. A patent inferior mesenteric artery and lumbar arteries can be spared and procedures that require crossing over the aortic bifurcation remain possible. Comorbidity, prior interventions, and disease extension can make this endovascular approach preferred over open repair. Isolated CIAA can be efficiently treated combining the BeGraft balloon expandable covered stent and IBD, which allows proximal sealing in the CIA. Elsevier 2018-03-28 /pmc/articles/PMC6033046/ /pubmed/29988832 http://dx.doi.org/10.1016/j.ejvssr.2018.03.002 Text en © 2018 The Author(s) http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Case Report
Vos, Cornelis G.
Schuurmann, Richte C.L.
de Vries, Jean-Paul P.M.
The BeGraft Balloon Expandable Covered Stent as a Proximal Extension to an Iliac Branch Device for Endovascular Repair of Isolated Common Iliac Artery Aneurysms
title The BeGraft Balloon Expandable Covered Stent as a Proximal Extension to an Iliac Branch Device for Endovascular Repair of Isolated Common Iliac Artery Aneurysms
title_full The BeGraft Balloon Expandable Covered Stent as a Proximal Extension to an Iliac Branch Device for Endovascular Repair of Isolated Common Iliac Artery Aneurysms
title_fullStr The BeGraft Balloon Expandable Covered Stent as a Proximal Extension to an Iliac Branch Device for Endovascular Repair of Isolated Common Iliac Artery Aneurysms
title_full_unstemmed The BeGraft Balloon Expandable Covered Stent as a Proximal Extension to an Iliac Branch Device for Endovascular Repair of Isolated Common Iliac Artery Aneurysms
title_short The BeGraft Balloon Expandable Covered Stent as a Proximal Extension to an Iliac Branch Device for Endovascular Repair of Isolated Common Iliac Artery Aneurysms
title_sort begraft balloon expandable covered stent as a proximal extension to an iliac branch device for endovascular repair of isolated common iliac artery aneurysms
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6033046/
https://www.ncbi.nlm.nih.gov/pubmed/29988832
http://dx.doi.org/10.1016/j.ejvssr.2018.03.002
work_keys_str_mv AT voscornelisg thebegraftballoonexpandablecoveredstentasaproximalextensiontoaniliacbranchdeviceforendovascularrepairofisolatedcommoniliacarteryaneurysms
AT schuurmannrichtecl thebegraftballoonexpandablecoveredstentasaproximalextensiontoaniliacbranchdeviceforendovascularrepairofisolatedcommoniliacarteryaneurysms
AT devriesjeanpaulpm thebegraftballoonexpandablecoveredstentasaproximalextensiontoaniliacbranchdeviceforendovascularrepairofisolatedcommoniliacarteryaneurysms
AT voscornelisg begraftballoonexpandablecoveredstentasaproximalextensiontoaniliacbranchdeviceforendovascularrepairofisolatedcommoniliacarteryaneurysms
AT schuurmannrichtecl begraftballoonexpandablecoveredstentasaproximalextensiontoaniliacbranchdeviceforendovascularrepairofisolatedcommoniliacarteryaneurysms
AT devriesjeanpaulpm begraftballoonexpandablecoveredstentasaproximalextensiontoaniliacbranchdeviceforendovascularrepairofisolatedcommoniliacarteryaneurysms