Cargando…

Design and application of an MR reference phantom for multicentre lung imaging trials

INTRODUCTION: As there is an increasing number of multicentre lung imaging studies with MRI in patients, dedicated reference phantoms are required to allow for the assessment and comparison of image quality in multi-vendor and multi-centre environments. However, appropriate phantoms for this purpose...

Descripción completa

Detalles Bibliográficos
Autores principales: Triphan, Simon M. F., Biederer, Jürgen, Burmester, Kerstin, Fellhauer, Iven, Vogelmeier, Claus F., Jörres, Rudolf A., Kauczor, Hans-Ulrich, Heußel, Claus P., Wielpütz, Mark O., Jobst, Bertram J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6033396/
https://www.ncbi.nlm.nih.gov/pubmed/29975714
http://dx.doi.org/10.1371/journal.pone.0199148
_version_ 1783337694572576768
author Triphan, Simon M. F.
Biederer, Jürgen
Burmester, Kerstin
Fellhauer, Iven
Vogelmeier, Claus F.
Jörres, Rudolf A.
Kauczor, Hans-Ulrich
Heußel, Claus P.
Wielpütz, Mark O.
Jobst, Bertram J.
author_facet Triphan, Simon M. F.
Biederer, Jürgen
Burmester, Kerstin
Fellhauer, Iven
Vogelmeier, Claus F.
Jörres, Rudolf A.
Kauczor, Hans-Ulrich
Heußel, Claus P.
Wielpütz, Mark O.
Jobst, Bertram J.
author_sort Triphan, Simon M. F.
collection PubMed
description INTRODUCTION: As there is an increasing number of multicentre lung imaging studies with MRI in patients, dedicated reference phantoms are required to allow for the assessment and comparison of image quality in multi-vendor and multi-centre environments. However, appropriate phantoms for this purpose are so far not available commercially. It was therefore the purpose of this project to design and apply a cost-effective and simple to use reference phantom which addresses the specific requirements for imaging the lungs with MRI. METHODS: The phantom was designed to simulate 4 compartments (lung, blood, muscle and fat) which reflect the specific conditions in proton-MRI of the chest. Multiple phantom instances were produced and measured at 15 sites using a contemporary proton-MRI protocol designed for an in vivo COPD study at intervals over the course of the study. Measures of signal- and contrast-to-noise ratio, as well as structure and edge depiction were extracted from conventionally acquired images using software written for this purpose. RESULTS: For the signal to noise ratio, low intra-scanner variability was found with 4.5% in the lung compartment, 4.0% for blood, 3.3% for muscle and 3.7% for fat. The inter-scanner variability was substantially higher, with 41%, 32%, 27% and 32% for the same order of compartments. In addition, measures of structure and edge depiction were found to both vary significantly among several scanner types and among scanners of the same model which were equipped with different gradient systems. CONCLUSION: The described reference phantom reproducibly quantified image quality aspects and detected substantial inter-scanner variability in a typical pulmonary multicentre proton MRI study, while variability was greater in lung tissue compared to other tissue types. Accordingly, appropriate reference phantoms can help to detect bias in multicentre in vivo study results and could also be used to harmonize equipment or data.
format Online
Article
Text
id pubmed-6033396
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-60333962018-07-19 Design and application of an MR reference phantom for multicentre lung imaging trials Triphan, Simon M. F. Biederer, Jürgen Burmester, Kerstin Fellhauer, Iven Vogelmeier, Claus F. Jörres, Rudolf A. Kauczor, Hans-Ulrich Heußel, Claus P. Wielpütz, Mark O. Jobst, Bertram J. PLoS One Research Article INTRODUCTION: As there is an increasing number of multicentre lung imaging studies with MRI in patients, dedicated reference phantoms are required to allow for the assessment and comparison of image quality in multi-vendor and multi-centre environments. However, appropriate phantoms for this purpose are so far not available commercially. It was therefore the purpose of this project to design and apply a cost-effective and simple to use reference phantom which addresses the specific requirements for imaging the lungs with MRI. METHODS: The phantom was designed to simulate 4 compartments (lung, blood, muscle and fat) which reflect the specific conditions in proton-MRI of the chest. Multiple phantom instances were produced and measured at 15 sites using a contemporary proton-MRI protocol designed for an in vivo COPD study at intervals over the course of the study. Measures of signal- and contrast-to-noise ratio, as well as structure and edge depiction were extracted from conventionally acquired images using software written for this purpose. RESULTS: For the signal to noise ratio, low intra-scanner variability was found with 4.5% in the lung compartment, 4.0% for blood, 3.3% for muscle and 3.7% for fat. The inter-scanner variability was substantially higher, with 41%, 32%, 27% and 32% for the same order of compartments. In addition, measures of structure and edge depiction were found to both vary significantly among several scanner types and among scanners of the same model which were equipped with different gradient systems. CONCLUSION: The described reference phantom reproducibly quantified image quality aspects and detected substantial inter-scanner variability in a typical pulmonary multicentre proton MRI study, while variability was greater in lung tissue compared to other tissue types. Accordingly, appropriate reference phantoms can help to detect bias in multicentre in vivo study results and could also be used to harmonize equipment or data. Public Library of Science 2018-07-05 /pmc/articles/PMC6033396/ /pubmed/29975714 http://dx.doi.org/10.1371/journal.pone.0199148 Text en © 2018 Triphan et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Triphan, Simon M. F.
Biederer, Jürgen
Burmester, Kerstin
Fellhauer, Iven
Vogelmeier, Claus F.
Jörres, Rudolf A.
Kauczor, Hans-Ulrich
Heußel, Claus P.
Wielpütz, Mark O.
Jobst, Bertram J.
Design and application of an MR reference phantom for multicentre lung imaging trials
title Design and application of an MR reference phantom for multicentre lung imaging trials
title_full Design and application of an MR reference phantom for multicentre lung imaging trials
title_fullStr Design and application of an MR reference phantom for multicentre lung imaging trials
title_full_unstemmed Design and application of an MR reference phantom for multicentre lung imaging trials
title_short Design and application of an MR reference phantom for multicentre lung imaging trials
title_sort design and application of an mr reference phantom for multicentre lung imaging trials
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6033396/
https://www.ncbi.nlm.nih.gov/pubmed/29975714
http://dx.doi.org/10.1371/journal.pone.0199148
work_keys_str_mv AT triphansimonmf designandapplicationofanmrreferencephantomformulticentrelungimagingtrials
AT biedererjurgen designandapplicationofanmrreferencephantomformulticentrelungimagingtrials
AT burmesterkerstin designandapplicationofanmrreferencephantomformulticentrelungimagingtrials
AT fellhaueriven designandapplicationofanmrreferencephantomformulticentrelungimagingtrials
AT vogelmeierclausf designandapplicationofanmrreferencephantomformulticentrelungimagingtrials
AT jorresrudolfa designandapplicationofanmrreferencephantomformulticentrelungimagingtrials
AT kauczorhansulrich designandapplicationofanmrreferencephantomformulticentrelungimagingtrials
AT heußelclausp designandapplicationofanmrreferencephantomformulticentrelungimagingtrials
AT wielputzmarko designandapplicationofanmrreferencephantomformulticentrelungimagingtrials
AT jobstbertramj designandapplicationofanmrreferencephantomformulticentrelungimagingtrials