Cargando…

Face, content, and construct validity of a novel chicken model for laparoscopic ureteric reimplantation

INTRODUCTION: Simulation-based training in laparoscopic urology is essential, as these surgeries require a different skill set. We validated a chicken model for laparoscopic left modified Lich Gregoir type of ureteric reimplantation. MATERIALS AND METHODS: Prospective observational study was conduct...

Descripción completa

Detalles Bibliográficos
Autores principales: Singh, Abhishek G., Jai, Shrikant J., Ganpule, Arvind P., Vijayakumar, Mohankumar, Sabnis, Ravindra B., Desai, Mahesh R.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6034421/
https://www.ncbi.nlm.nih.gov/pubmed/30034129
http://dx.doi.org/10.4103/iju.IJU_46_18
_version_ 1783337878139437056
author Singh, Abhishek G.
Jai, Shrikant J.
Ganpule, Arvind P.
Vijayakumar, Mohankumar
Sabnis, Ravindra B.
Desai, Mahesh R.
author_facet Singh, Abhishek G.
Jai, Shrikant J.
Ganpule, Arvind P.
Vijayakumar, Mohankumar
Sabnis, Ravindra B.
Desai, Mahesh R.
author_sort Singh, Abhishek G.
collection PubMed
description INTRODUCTION: Simulation-based training in laparoscopic urology is essential, as these surgeries require a different skill set. We validated a chicken model for laparoscopic left modified Lich Gregoir type of ureteric reimplantation. MATERIALS AND METHODS: Prospective observational study was conducted from August 2016 till February 2017. Thirty novice surgeons and 20 trained laparoscopic surgeons were included in the study. The relevant chicken anatomy and surgical steps were described to all the surgeons. The surgeons were asked to fill an eight-point questionnaire after finishing the procedure and score it on a scale of 1–5. The trainee's performance was also recorded by an investigator on a proforma. The investigator recorded dissection time, suturing time, quality of dissection, quality of suturing, and integrity of anastomosis on a scale of 1–5. RESULTS: All the participants in the study gave a mean score of 3 or more to all the questions asked, except for one question pertaining to tissue feel. Both the groups rated the usefulness of the model very highly with a mean score of 4.20 and 4.15, respectively. Difference in the time taken for dissection and suturing along with the quality of suturing was statistically significant in favor of the expert group. CONCLUSIONS: The chicken model for laparoscopic left modified Lich Gregoir type of ureteric reimplantation is a useful, effective, cognitive training tool. This model has a face, content, and construct validity to be used as a teaching and learning tool in laparoscopic urology.
format Online
Article
Text
id pubmed-6034421
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-60344212018-07-20 Face, content, and construct validity of a novel chicken model for laparoscopic ureteric reimplantation Singh, Abhishek G. Jai, Shrikant J. Ganpule, Arvind P. Vijayakumar, Mohankumar Sabnis, Ravindra B. Desai, Mahesh R. Indian J Urol Original Article INTRODUCTION: Simulation-based training in laparoscopic urology is essential, as these surgeries require a different skill set. We validated a chicken model for laparoscopic left modified Lich Gregoir type of ureteric reimplantation. MATERIALS AND METHODS: Prospective observational study was conducted from August 2016 till February 2017. Thirty novice surgeons and 20 trained laparoscopic surgeons were included in the study. The relevant chicken anatomy and surgical steps were described to all the surgeons. The surgeons were asked to fill an eight-point questionnaire after finishing the procedure and score it on a scale of 1–5. The trainee's performance was also recorded by an investigator on a proforma. The investigator recorded dissection time, suturing time, quality of dissection, quality of suturing, and integrity of anastomosis on a scale of 1–5. RESULTS: All the participants in the study gave a mean score of 3 or more to all the questions asked, except for one question pertaining to tissue feel. Both the groups rated the usefulness of the model very highly with a mean score of 4.20 and 4.15, respectively. Difference in the time taken for dissection and suturing along with the quality of suturing was statistically significant in favor of the expert group. CONCLUSIONS: The chicken model for laparoscopic left modified Lich Gregoir type of ureteric reimplantation is a useful, effective, cognitive training tool. This model has a face, content, and construct validity to be used as a teaching and learning tool in laparoscopic urology. Medknow Publications & Media Pvt Ltd 2018 /pmc/articles/PMC6034421/ /pubmed/30034129 http://dx.doi.org/10.4103/iju.IJU_46_18 Text en Copyright: © 2018 Indian Journal of Urology http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Singh, Abhishek G.
Jai, Shrikant J.
Ganpule, Arvind P.
Vijayakumar, Mohankumar
Sabnis, Ravindra B.
Desai, Mahesh R.
Face, content, and construct validity of a novel chicken model for laparoscopic ureteric reimplantation
title Face, content, and construct validity of a novel chicken model for laparoscopic ureteric reimplantation
title_full Face, content, and construct validity of a novel chicken model for laparoscopic ureteric reimplantation
title_fullStr Face, content, and construct validity of a novel chicken model for laparoscopic ureteric reimplantation
title_full_unstemmed Face, content, and construct validity of a novel chicken model for laparoscopic ureteric reimplantation
title_short Face, content, and construct validity of a novel chicken model for laparoscopic ureteric reimplantation
title_sort face, content, and construct validity of a novel chicken model for laparoscopic ureteric reimplantation
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6034421/
https://www.ncbi.nlm.nih.gov/pubmed/30034129
http://dx.doi.org/10.4103/iju.IJU_46_18
work_keys_str_mv AT singhabhishekg facecontentandconstructvalidityofanovelchickenmodelforlaparoscopicuretericreimplantation
AT jaishrikantj facecontentandconstructvalidityofanovelchickenmodelforlaparoscopicuretericreimplantation
AT ganpulearvindp facecontentandconstructvalidityofanovelchickenmodelforlaparoscopicuretericreimplantation
AT vijayakumarmohankumar facecontentandconstructvalidityofanovelchickenmodelforlaparoscopicuretericreimplantation
AT sabnisravindrab facecontentandconstructvalidityofanovelchickenmodelforlaparoscopicuretericreimplantation
AT desaimaheshr facecontentandconstructvalidityofanovelchickenmodelforlaparoscopicuretericreimplantation