Cargando…
Evaluation of 153 Asymptomatic Subjects Using the Anopress Portable Anal Manometry Device
BACKGROUND/AIMS: The Anopress device is a new portable manometry system. The aim of this study is to formulate normative data using this new device by recording the anorectal function of asymptomatic subjects. Patient comfort was also assessed. METHODS: Anorectal function was assessed in asymptomati...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Society of Neurogastroenterology and Motility
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6034678/ https://www.ncbi.nlm.nih.gov/pubmed/29879763 http://dx.doi.org/10.5056/jnm17135 |
_version_ | 1783337920522878976 |
---|---|
author | Leo, Cosimo Alex Cavazzoni, Emanuel Thomas, Gregory P Hodgkison, Jonathan Murphy, Jamie Vaizey, Carolynne J |
author_facet | Leo, Cosimo Alex Cavazzoni, Emanuel Thomas, Gregory P Hodgkison, Jonathan Murphy, Jamie Vaizey, Carolynne J |
author_sort | Leo, Cosimo Alex |
collection | PubMed |
description | BACKGROUND/AIMS: The Anopress device is a new portable manometry system. The aim of this study is to formulate normative data using this new device by recording the anorectal function of asymptomatic subjects. Patient comfort was also assessed. METHODS: Anorectal function was assessed in asymptomatic volunteers using the Anopress. All volunteers were examined in a standardized way in accordance with the study protocol. Normative values for the Anopress were obtained from the recorded data and patient comfort was assessed using a visual analogue scale. RESULTS: We recruited 153 healthy volunteers. Eighty were female (23 parous; median age 39.5 [interquartile range {IQR}, 28.75–53.00]) and 73 were male (median age 40.5 [IQR, 29.00–52.25]). For the female cohort, the following normal range (2.5–97.5 percentile) values were recorded across the whole anal canal: resting pressure 40.0–103.0 mmHg; squeeze increment 35.0–140.6 mmHg; endurance 1.3–9.0 seconds; involuntary squeeze 41.1–120.8 mmHg; and strain pressure 22.1–77.9 mmHg. Similarly, the following male normal range (2.5–97.5 percentile) values were recorded across the whole anal canal: resting pressure 38.3–99.6 mmHg; squeeze increment 42.5–154.8 mmHg; involuntary squeeze 40.0–123.6 mmHg; endurance 2.0–10.0 seconds; and strain pressure 11.0–72.1 mmHg. The median visual analogue scale scores for discomfort during the measurement was 0.0 (IQR, 0.00–0.00). CONCLUSIONS: Normative values for the Anopress device have been calculated by this study. The Anopress appears to be a safe and well tolerated way of measuring pressures from the entire anal canal. Further comparisons with other standard and commonly used manometry tests are, however, required to verify its reliability. |
format | Online Article Text |
id | pubmed-6034678 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Korean Society of Neurogastroenterology and Motility |
record_format | MEDLINE/PubMed |
spelling | pubmed-60346782018-07-12 Evaluation of 153 Asymptomatic Subjects Using the Anopress Portable Anal Manometry Device Leo, Cosimo Alex Cavazzoni, Emanuel Thomas, Gregory P Hodgkison, Jonathan Murphy, Jamie Vaizey, Carolynne J J Neurogastroenterol Motil Original Article BACKGROUND/AIMS: The Anopress device is a new portable manometry system. The aim of this study is to formulate normative data using this new device by recording the anorectal function of asymptomatic subjects. Patient comfort was also assessed. METHODS: Anorectal function was assessed in asymptomatic volunteers using the Anopress. All volunteers were examined in a standardized way in accordance with the study protocol. Normative values for the Anopress were obtained from the recorded data and patient comfort was assessed using a visual analogue scale. RESULTS: We recruited 153 healthy volunteers. Eighty were female (23 parous; median age 39.5 [interquartile range {IQR}, 28.75–53.00]) and 73 were male (median age 40.5 [IQR, 29.00–52.25]). For the female cohort, the following normal range (2.5–97.5 percentile) values were recorded across the whole anal canal: resting pressure 40.0–103.0 mmHg; squeeze increment 35.0–140.6 mmHg; endurance 1.3–9.0 seconds; involuntary squeeze 41.1–120.8 mmHg; and strain pressure 22.1–77.9 mmHg. Similarly, the following male normal range (2.5–97.5 percentile) values were recorded across the whole anal canal: resting pressure 38.3–99.6 mmHg; squeeze increment 42.5–154.8 mmHg; involuntary squeeze 40.0–123.6 mmHg; endurance 2.0–10.0 seconds; and strain pressure 11.0–72.1 mmHg. The median visual analogue scale scores for discomfort during the measurement was 0.0 (IQR, 0.00–0.00). CONCLUSIONS: Normative values for the Anopress device have been calculated by this study. The Anopress appears to be a safe and well tolerated way of measuring pressures from the entire anal canal. Further comparisons with other standard and commonly used manometry tests are, however, required to verify its reliability. Korean Society of Neurogastroenterology and Motility 2018-07 2018-07-01 /pmc/articles/PMC6034678/ /pubmed/29879763 http://dx.doi.org/10.5056/jnm17135 Text en © 2018 The Korean Society of Neurogastroenterology and Motility This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Leo, Cosimo Alex Cavazzoni, Emanuel Thomas, Gregory P Hodgkison, Jonathan Murphy, Jamie Vaizey, Carolynne J Evaluation of 153 Asymptomatic Subjects Using the Anopress Portable Anal Manometry Device |
title | Evaluation of 153 Asymptomatic Subjects Using the Anopress Portable Anal Manometry Device |
title_full | Evaluation of 153 Asymptomatic Subjects Using the Anopress Portable Anal Manometry Device |
title_fullStr | Evaluation of 153 Asymptomatic Subjects Using the Anopress Portable Anal Manometry Device |
title_full_unstemmed | Evaluation of 153 Asymptomatic Subjects Using the Anopress Portable Anal Manometry Device |
title_short | Evaluation of 153 Asymptomatic Subjects Using the Anopress Portable Anal Manometry Device |
title_sort | evaluation of 153 asymptomatic subjects using the anopress portable anal manometry device |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6034678/ https://www.ncbi.nlm.nih.gov/pubmed/29879763 http://dx.doi.org/10.5056/jnm17135 |
work_keys_str_mv | AT leocosimoalex evaluationof153asymptomaticsubjectsusingtheanopressportableanalmanometrydevice AT cavazzoniemanuel evaluationof153asymptomaticsubjectsusingtheanopressportableanalmanometrydevice AT thomasgregoryp evaluationof153asymptomaticsubjectsusingtheanopressportableanalmanometrydevice AT hodgkisonjonathan evaluationof153asymptomaticsubjectsusingtheanopressportableanalmanometrydevice AT murphyjamie evaluationof153asymptomaticsubjectsusingtheanopressportableanalmanometrydevice AT vaizeycarolynnej evaluationof153asymptomaticsubjectsusingtheanopressportableanalmanometrydevice |