Cargando…

Internal quality assurance of HIL indices on Roche Cobas c702

Automatic assessment of hemoglobin (H), lipaemia (L) and icterus (I) in serum or plasma (HIL indices) is the mainstay for evaluating sample quality. We planned this study to verify whether in-house prepared internal quality control (IQC) materials may be suitable for quality assurance of HIL indices...

Descripción completa

Detalles Bibliográficos
Autores principales: Lippi, Giuseppe, Cadamuro, Janne, Danese, Elisa, Gelati, Matteo, Montagnana, Martina, von Meyer, Alexander, Salvagno, Gian Luca, Simundic, Ana-Maria
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6034854/
https://www.ncbi.nlm.nih.gov/pubmed/29979722
http://dx.doi.org/10.1371/journal.pone.0200088
_version_ 1783337949242327040
author Lippi, Giuseppe
Cadamuro, Janne
Danese, Elisa
Gelati, Matteo
Montagnana, Martina
von Meyer, Alexander
Salvagno, Gian Luca
Simundic, Ana-Maria
author_facet Lippi, Giuseppe
Cadamuro, Janne
Danese, Elisa
Gelati, Matteo
Montagnana, Martina
von Meyer, Alexander
Salvagno, Gian Luca
Simundic, Ana-Maria
author_sort Lippi, Giuseppe
collection PubMed
description Automatic assessment of hemoglobin (H), lipaemia (L) and icterus (I) in serum or plasma (HIL indices) is the mainstay for evaluating sample quality. We planned this study to verify whether in-house prepared internal quality control (IQC) materials may be suitable for quality assurance of HIL indices. Pools containing different values of each of the three HIL indices were prepared from routine plasma samples, divided in aliquots and frozen at -20°C. Stability of frozen materials was assessed by thawing one aliquot of each pool after different days of freezing (1, 4, 8, 15, 22 and 29), and by measuring HIL indices on baseline fresh samples and frozen-thawed aliquots with Roche Cobas c702. Five fresh liquid IQCs materials were also measured at the same time points. Intra-assay and inter-assay imprecision of HIL indices calculated with commercial IQC materials ranged between 1.1–2.0% and 1.6–3.3%, respectively. When target values of HIL indices were calculated using frozen-thawed aliquots, the inter-assay imprecision of in-house prepared materials was optimal, even better than that of commercial liquid IQCs (H-index, 0.8% versus 1.6%; L-index, 2.2% versus 2.5%; I-index, 0.8% versus 3.3%). In conclusion, in-house prepared IQC materials are cost-effective alternatives to commercial liquid IQCs for HIL quality assurance.
format Online
Article
Text
id pubmed-6034854
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-60348542018-07-19 Internal quality assurance of HIL indices on Roche Cobas c702 Lippi, Giuseppe Cadamuro, Janne Danese, Elisa Gelati, Matteo Montagnana, Martina von Meyer, Alexander Salvagno, Gian Luca Simundic, Ana-Maria PLoS One Research Article Automatic assessment of hemoglobin (H), lipaemia (L) and icterus (I) in serum or plasma (HIL indices) is the mainstay for evaluating sample quality. We planned this study to verify whether in-house prepared internal quality control (IQC) materials may be suitable for quality assurance of HIL indices. Pools containing different values of each of the three HIL indices were prepared from routine plasma samples, divided in aliquots and frozen at -20°C. Stability of frozen materials was assessed by thawing one aliquot of each pool after different days of freezing (1, 4, 8, 15, 22 and 29), and by measuring HIL indices on baseline fresh samples and frozen-thawed aliquots with Roche Cobas c702. Five fresh liquid IQCs materials were also measured at the same time points. Intra-assay and inter-assay imprecision of HIL indices calculated with commercial IQC materials ranged between 1.1–2.0% and 1.6–3.3%, respectively. When target values of HIL indices were calculated using frozen-thawed aliquots, the inter-assay imprecision of in-house prepared materials was optimal, even better than that of commercial liquid IQCs (H-index, 0.8% versus 1.6%; L-index, 2.2% versus 2.5%; I-index, 0.8% versus 3.3%). In conclusion, in-house prepared IQC materials are cost-effective alternatives to commercial liquid IQCs for HIL quality assurance. Public Library of Science 2018-07-06 /pmc/articles/PMC6034854/ /pubmed/29979722 http://dx.doi.org/10.1371/journal.pone.0200088 Text en © 2018 Lippi et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Lippi, Giuseppe
Cadamuro, Janne
Danese, Elisa
Gelati, Matteo
Montagnana, Martina
von Meyer, Alexander
Salvagno, Gian Luca
Simundic, Ana-Maria
Internal quality assurance of HIL indices on Roche Cobas c702
title Internal quality assurance of HIL indices on Roche Cobas c702
title_full Internal quality assurance of HIL indices on Roche Cobas c702
title_fullStr Internal quality assurance of HIL indices on Roche Cobas c702
title_full_unstemmed Internal quality assurance of HIL indices on Roche Cobas c702
title_short Internal quality assurance of HIL indices on Roche Cobas c702
title_sort internal quality assurance of hil indices on roche cobas c702
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6034854/
https://www.ncbi.nlm.nih.gov/pubmed/29979722
http://dx.doi.org/10.1371/journal.pone.0200088
work_keys_str_mv AT lippigiuseppe internalqualityassuranceofhilindicesonrochecobasc702
AT cadamurojanne internalqualityassuranceofhilindicesonrochecobasc702
AT daneseelisa internalqualityassuranceofhilindicesonrochecobasc702
AT gelatimatteo internalqualityassuranceofhilindicesonrochecobasc702
AT montagnanamartina internalqualityassuranceofhilindicesonrochecobasc702
AT vonmeyeralexander internalqualityassuranceofhilindicesonrochecobasc702
AT salvagnogianluca internalqualityassuranceofhilindicesonrochecobasc702
AT simundicanamaria internalqualityassuranceofhilindicesonrochecobasc702