Cargando…
Discontinuation of anticoagulant therapy for a month in a patient with HeartMate III continuous-flow left ventricular assist device without thromboembolic events
The recommended anticoagulation regimen for continuous-flow left ventricular assist device (LVAD) systems is warfarin and aspirin with a targeted international normalized ratio (INR) of 2.0–3.0. Our patient is a 58-year-old male who underwent surgical HeartMate III continuous-flow LVAD implantation...
Autores principales: | Elasfar, Abdelfatah, Jalali, Kafaf, Hussein, Mohamed, AlHarbi, Ibraheem, Amoudi, Osama |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6035384/ https://www.ncbi.nlm.nih.gov/pubmed/29989026 http://dx.doi.org/10.1016/j.jsha.2017.12.002 |
Ejemplares similares
-
Endovascular repair of severe aortic coarctation, transcatheter aortic valve replacement for severe aortic stenosis, and percutaneous coronary intervention in an elderly patient with long term follow-up
por: Fallatah, Raneem, et al.
Publicado: (2018) -
Thromboembolic stroke in patients with a HeartMate-II left ventricular assist device – the role of anticoagulation
por: van den Bergh, Walter M., et al.
Publicado: (2015) -
Successful Pediatric Mechanical Thrombectomy for HeartMate
3-Related Intracranial Thromboembolism
por: Proulx, Catherine, et al.
Publicado: (2022) -
Long-Term Withdrawal of Anticoagulation and Antiplatelet Therapy in a HeartMate 3 Left Ventricular Assist Device
por: Menchaca, Kristina, et al.
Publicado: (2022) -
Conservative initial postoperative anticoagulation strategy after HeartMate 3 left ventricular assist device implantation
por: Damman, Kevin, et al.
Publicado: (2022)