Cargando…

Beam focal spot position determination for an Elekta linac with the Agility(®) head; practical guide with a ready‐to‐go procedure

A novel phantomless, EPID‐based method of measuring the beam focal spot offset of a linear accelerator was proposed and validated for Varian machines. In this method, one set of jaws and the MLC were utilized to form a symmetric field and then a 180(o) collimator rotation was utilized to determine t...

Descripción completa

Detalles Bibliográficos
Autores principales: Chojnowski, Jacek M., Taylor, Lee M., Sykes, Jonathan R., Thwaites, David I.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6036348/
https://www.ncbi.nlm.nih.gov/pubmed/29761625
http://dx.doi.org/10.1002/acm2.12344
_version_ 1783338149067358208
author Chojnowski, Jacek M.
Taylor, Lee M.
Sykes, Jonathan R.
Thwaites, David I.
author_facet Chojnowski, Jacek M.
Taylor, Lee M.
Sykes, Jonathan R.
Thwaites, David I.
author_sort Chojnowski, Jacek M.
collection PubMed
description A novel phantomless, EPID‐based method of measuring the beam focal spot offset of a linear accelerator was proposed and validated for Varian machines. In this method, one set of jaws and the MLC were utilized to form a symmetric field and then a 180(o) collimator rotation was utilized to determine the radiation isocenter defined by the jaws and the MLC, respectively. The difference between these two isocentres is directly correlated with the beam focal spot offset of the linear accelerator. In the current work, the method has been considered for Elekta linacs. An Elekta linac with the Agility(®) head does not have two set of jaws, therefore, a modified method is presented making use of one set of diaphragms, the MLC and a full 360(o) collimator rotation. The modified method has been tested on two Elekta Synergy(®) linacs with Agility(®) heads and independently validated. A practical guide with instructions and a MATLAB (®) code is attached for easy implementation.
format Online
Article
Text
id pubmed-6036348
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-60363482018-07-12 Beam focal spot position determination for an Elekta linac with the Agility(®) head; practical guide with a ready‐to‐go procedure Chojnowski, Jacek M. Taylor, Lee M. Sykes, Jonathan R. Thwaites, David I. J Appl Clin Med Phys Radiation Oncology Physics A novel phantomless, EPID‐based method of measuring the beam focal spot offset of a linear accelerator was proposed and validated for Varian machines. In this method, one set of jaws and the MLC were utilized to form a symmetric field and then a 180(o) collimator rotation was utilized to determine the radiation isocenter defined by the jaws and the MLC, respectively. The difference between these two isocentres is directly correlated with the beam focal spot offset of the linear accelerator. In the current work, the method has been considered for Elekta linacs. An Elekta linac with the Agility(®) head does not have two set of jaws, therefore, a modified method is presented making use of one set of diaphragms, the MLC and a full 360(o) collimator rotation. The modified method has been tested on two Elekta Synergy(®) linacs with Agility(®) heads and independently validated. A practical guide with instructions and a MATLAB (®) code is attached for easy implementation. John Wiley and Sons Inc. 2018-05-14 /pmc/articles/PMC6036348/ /pubmed/29761625 http://dx.doi.org/10.1002/acm2.12344 Text en © 2018 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine. This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Radiation Oncology Physics
Chojnowski, Jacek M.
Taylor, Lee M.
Sykes, Jonathan R.
Thwaites, David I.
Beam focal spot position determination for an Elekta linac with the Agility(®) head; practical guide with a ready‐to‐go procedure
title Beam focal spot position determination for an Elekta linac with the Agility(®) head; practical guide with a ready‐to‐go procedure
title_full Beam focal spot position determination for an Elekta linac with the Agility(®) head; practical guide with a ready‐to‐go procedure
title_fullStr Beam focal spot position determination for an Elekta linac with the Agility(®) head; practical guide with a ready‐to‐go procedure
title_full_unstemmed Beam focal spot position determination for an Elekta linac with the Agility(®) head; practical guide with a ready‐to‐go procedure
title_short Beam focal spot position determination for an Elekta linac with the Agility(®) head; practical guide with a ready‐to‐go procedure
title_sort beam focal spot position determination for an elekta linac with the agility(®) head; practical guide with a ready‐to‐go procedure
topic Radiation Oncology Physics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6036348/
https://www.ncbi.nlm.nih.gov/pubmed/29761625
http://dx.doi.org/10.1002/acm2.12344
work_keys_str_mv AT chojnowskijacekm beamfocalspotpositiondeterminationforanelektalinacwiththeagilityheadpracticalguidewithareadytogoprocedure
AT taylorleem beamfocalspotpositiondeterminationforanelektalinacwiththeagilityheadpracticalguidewithareadytogoprocedure
AT sykesjonathanr beamfocalspotpositiondeterminationforanelektalinacwiththeagilityheadpracticalguidewithareadytogoprocedure
AT thwaitesdavidi beamfocalspotpositiondeterminationforanelektalinacwiththeagilityheadpracticalguidewithareadytogoprocedure