Application of contrast-enhanced ultrasound and enhanced CT in diagnosis of liver cancer and evaluation of radiofrequency ablation

This study investigated the application effect of contrast-enhanced ultrasound (CEUS) and enhanced CT in diagnosis of liver cancer and response evaluation of radiofrequency ablation (RFA). A total of 60 patients with liver cancer were selected in Dongying People's Hospital from April 2016 to Ma...

Descripción completa

Detalles Bibliográficos
Autores principales: Kong, Shuhong, Yue, Xuewang, Kong, Sheng, Ren, Yujie
Formato: Online Artículo Texto
Lenguaje:English
Publicado: D.A. Spandidos 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6036569/
https://www.ncbi.nlm.nih.gov/pubmed/30013634
http://dx.doi.org/10.3892/ol.2018.8898
_version_ 1783338187143249920
author Kong, Shuhong
Yue, Xuewang
Kong, Sheng
Ren, Yujie
author_facet Kong, Shuhong
Yue, Xuewang
Kong, Sheng
Ren, Yujie
author_sort Kong, Shuhong
collection PubMed
description This study investigated the application effect of contrast-enhanced ultrasound (CEUS) and enhanced CT in diagnosis of liver cancer and response evaluation of radiofrequency ablation (RFA). A total of 60 patients with liver cancer were selected in Dongying People's Hospital from April 2016 to May 2017. All patients were subjected to CEUS and enhanced CT. With pathological examination as the gold standard, diagnostic consistency of the two methods was compared. After RFA, patients were subjected to CEUS and enhanced CT to assess the efficacy, and the consistency was compared. There was no significant difference in diagnostic accuracy between CEUS and CT (p>0.05). Area under the ROC curve of CEUS was 0.896, with a sensitivity of 91.2% and a specificity of 88.7%. The area under the ROC curve for enhanced CT diagnosis was 0.907, with a sensitivity of 91.8% and a specificity of 89.7%. No significant difference in the maximal cross sectional area of lesions was found between CEUS and enhanced CT, and there was no significant difference in evaluation of therapeutic efficiency between the methods (p>0.05) before and 1 and 3 months after treatment. Bland-Altman test showed that there was a strong consistency between CEUS and enhanced CT in the measured maximum cross-sectional area of lesions at 1 and 3 months after treatment. Linear regression analysis showed that maximum section cross-sectional area measured by CEUS was significantly correlated with that detected by enhanced CT (r(2)=0.617). The results suggested that diagnostic efficiency of CEUS was similar to that of enhanced CT, and both showed high sensitivity and specificity. Two methods showed high consistency in evaluating the curative effect of RFA. CEUS can achieve real-time observation of focal blood flow perfusion, and was more economically affordable and convenient.
format Online
Article
Text
id pubmed-6036569
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher D.A. Spandidos
record_format MEDLINE/PubMed
spelling pubmed-60365692018-07-16 Application of contrast-enhanced ultrasound and enhanced CT in diagnosis of liver cancer and evaluation of radiofrequency ablation Kong, Shuhong Yue, Xuewang Kong, Sheng Ren, Yujie Oncol Lett Articles This study investigated the application effect of contrast-enhanced ultrasound (CEUS) and enhanced CT in diagnosis of liver cancer and response evaluation of radiofrequency ablation (RFA). A total of 60 patients with liver cancer were selected in Dongying People's Hospital from April 2016 to May 2017. All patients were subjected to CEUS and enhanced CT. With pathological examination as the gold standard, diagnostic consistency of the two methods was compared. After RFA, patients were subjected to CEUS and enhanced CT to assess the efficacy, and the consistency was compared. There was no significant difference in diagnostic accuracy between CEUS and CT (p>0.05). Area under the ROC curve of CEUS was 0.896, with a sensitivity of 91.2% and a specificity of 88.7%. The area under the ROC curve for enhanced CT diagnosis was 0.907, with a sensitivity of 91.8% and a specificity of 89.7%. No significant difference in the maximal cross sectional area of lesions was found between CEUS and enhanced CT, and there was no significant difference in evaluation of therapeutic efficiency between the methods (p>0.05) before and 1 and 3 months after treatment. Bland-Altman test showed that there was a strong consistency between CEUS and enhanced CT in the measured maximum cross-sectional area of lesions at 1 and 3 months after treatment. Linear regression analysis showed that maximum section cross-sectional area measured by CEUS was significantly correlated with that detected by enhanced CT (r(2)=0.617). The results suggested that diagnostic efficiency of CEUS was similar to that of enhanced CT, and both showed high sensitivity and specificity. Two methods showed high consistency in evaluating the curative effect of RFA. CEUS can achieve real-time observation of focal blood flow perfusion, and was more economically affordable and convenient. D.A. Spandidos 2018-08 2018-06-05 /pmc/articles/PMC6036569/ /pubmed/30013634 http://dx.doi.org/10.3892/ol.2018.8898 Text en Copyright: © Kong et al. This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs License (https://creativecommons.org/licenses/by-nc-nd/4.0/) , which permits use and distribution in any medium, provided the original work is properly cited, the use is non-commercial and no modifications or adaptations are made.
spellingShingle Articles
Kong, Shuhong
Yue, Xuewang
Kong, Sheng
Ren, Yujie
Application of contrast-enhanced ultrasound and enhanced CT in diagnosis of liver cancer and evaluation of radiofrequency ablation
title Application of contrast-enhanced ultrasound and enhanced CT in diagnosis of liver cancer and evaluation of radiofrequency ablation
title_full Application of contrast-enhanced ultrasound and enhanced CT in diagnosis of liver cancer and evaluation of radiofrequency ablation
title_fullStr Application of contrast-enhanced ultrasound and enhanced CT in diagnosis of liver cancer and evaluation of radiofrequency ablation
title_full_unstemmed Application of contrast-enhanced ultrasound and enhanced CT in diagnosis of liver cancer and evaluation of radiofrequency ablation
title_short Application of contrast-enhanced ultrasound and enhanced CT in diagnosis of liver cancer and evaluation of radiofrequency ablation
title_sort application of contrast-enhanced ultrasound and enhanced ct in diagnosis of liver cancer and evaluation of radiofrequency ablation
topic Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6036569/
https://www.ncbi.nlm.nih.gov/pubmed/30013634
http://dx.doi.org/10.3892/ol.2018.8898
work_keys_str_mv AT kongshuhong applicationofcontrastenhancedultrasoundandenhancedctindiagnosisoflivercancerandevaluationofradiofrequencyablation
AT yuexuewang applicationofcontrastenhancedultrasoundandenhancedctindiagnosisoflivercancerandevaluationofradiofrequencyablation
AT kongsheng applicationofcontrastenhancedultrasoundandenhancedctindiagnosisoflivercancerandevaluationofradiofrequencyablation
AT renyujie applicationofcontrastenhancedultrasoundandenhancedctindiagnosisoflivercancerandevaluationofradiofrequencyablation