Long scan depth optical coherence tomography on imaging accommodation: impact of enhanced axial resolution, signal-to-noise ratio and speed

BACKGROUND: Spectral domain optical coherence tomography (SD-OCT) was a useful tool to study accommodation in human eye, but the maximum image depth is limited due to the decreased signal-to-noise ratio (SNR). In this study, improving optical resolutions, speeds and the SNR were achieved by custom b...

Descripción completa

Detalles Bibliográficos
Autores principales: Shao, Yilei, Tao, Aizhu, Jiang, Hong, Shen, Meixiao, Zhu, Dexi, Lu, Fan, Karp, Carol L., Ye, Yufeng, Wang, Jianhua
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6036665/
https://www.ncbi.nlm.nih.gov/pubmed/30003116
http://dx.doi.org/10.1186/s40662-018-0111-4
_version_ 1783338194419318784
author Shao, Yilei
Tao, Aizhu
Jiang, Hong
Shen, Meixiao
Zhu, Dexi
Lu, Fan
Karp, Carol L.
Ye, Yufeng
Wang, Jianhua
author_facet Shao, Yilei
Tao, Aizhu
Jiang, Hong
Shen, Meixiao
Zhu, Dexi
Lu, Fan
Karp, Carol L.
Ye, Yufeng
Wang, Jianhua
author_sort Shao, Yilei
collection PubMed
description BACKGROUND: Spectral domain optical coherence tomography (SD-OCT) was a useful tool to study accommodation in human eye, but the maximum image depth is limited due to the decreased signal-to-noise ratio (SNR). In this study, improving optical resolutions, speeds and the SNR were achieved by custom built SD-OCT, and the evaluation of the impact of the improvement during accommodation was investigated. METHODS: Three systems with different spectrometer designs, including two Charge Coupled Device (CCD) cameras and one Complementary Metal-Oxide-Semiconductor Transistor (CMOS) camera, were tested. We measured the point spread functions of a mirror at different positions to obtain the axial resolution and the SNR of three OCT systems powered with a light source with a 50 nm bandwidth, centered at a wavelength of 840 nm. Two normal subjects, aged 26 and 47, respectively, and one 75-year-old patient with an intraocular lens implanted were imaged. RESULTS: The results indicated that spectrometers using cameras with 4096 camera pixels optimized the axial resolutions, due to the use of the full spectrum provided by the light source. The CCD camera system with 4096 pixels had the highest SNR and the best image quality. The system with the CMOS camera with 4096 pixels had the highest speed but had a compromised SNR compared to the CCD camera with 4096 pixels. CONCLUSIONS: Using these three OCT systems, we imaged the anterior segment of the human eye before and after accommodation, which showed similar results among the different systems. The system using the CMOS camera with an ultra-long scan depth, high resolution and high scan speed exhibited the best overall performance and therefore was recommended for imaging real-time accommodation.
format Online
Article
Text
id pubmed-6036665
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-60366652018-07-12 Long scan depth optical coherence tomography on imaging accommodation: impact of enhanced axial resolution, signal-to-noise ratio and speed Shao, Yilei Tao, Aizhu Jiang, Hong Shen, Meixiao Zhu, Dexi Lu, Fan Karp, Carol L. Ye, Yufeng Wang, Jianhua Eye Vis (Lond) Research BACKGROUND: Spectral domain optical coherence tomography (SD-OCT) was a useful tool to study accommodation in human eye, but the maximum image depth is limited due to the decreased signal-to-noise ratio (SNR). In this study, improving optical resolutions, speeds and the SNR were achieved by custom built SD-OCT, and the evaluation of the impact of the improvement during accommodation was investigated. METHODS: Three systems with different spectrometer designs, including two Charge Coupled Device (CCD) cameras and one Complementary Metal-Oxide-Semiconductor Transistor (CMOS) camera, were tested. We measured the point spread functions of a mirror at different positions to obtain the axial resolution and the SNR of three OCT systems powered with a light source with a 50 nm bandwidth, centered at a wavelength of 840 nm. Two normal subjects, aged 26 and 47, respectively, and one 75-year-old patient with an intraocular lens implanted were imaged. RESULTS: The results indicated that spectrometers using cameras with 4096 camera pixels optimized the axial resolutions, due to the use of the full spectrum provided by the light source. The CCD camera system with 4096 pixels had the highest SNR and the best image quality. The system with the CMOS camera with 4096 pixels had the highest speed but had a compromised SNR compared to the CCD camera with 4096 pixels. CONCLUSIONS: Using these three OCT systems, we imaged the anterior segment of the human eye before and after accommodation, which showed similar results among the different systems. The system using the CMOS camera with an ultra-long scan depth, high resolution and high scan speed exhibited the best overall performance and therefore was recommended for imaging real-time accommodation. BioMed Central 2018-07-09 /pmc/articles/PMC6036665/ /pubmed/30003116 http://dx.doi.org/10.1186/s40662-018-0111-4 Text en © The Author(s). 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Shao, Yilei
Tao, Aizhu
Jiang, Hong
Shen, Meixiao
Zhu, Dexi
Lu, Fan
Karp, Carol L.
Ye, Yufeng
Wang, Jianhua
Long scan depth optical coherence tomography on imaging accommodation: impact of enhanced axial resolution, signal-to-noise ratio and speed
title Long scan depth optical coherence tomography on imaging accommodation: impact of enhanced axial resolution, signal-to-noise ratio and speed
title_full Long scan depth optical coherence tomography on imaging accommodation: impact of enhanced axial resolution, signal-to-noise ratio and speed
title_fullStr Long scan depth optical coherence tomography on imaging accommodation: impact of enhanced axial resolution, signal-to-noise ratio and speed
title_full_unstemmed Long scan depth optical coherence tomography on imaging accommodation: impact of enhanced axial resolution, signal-to-noise ratio and speed
title_short Long scan depth optical coherence tomography on imaging accommodation: impact of enhanced axial resolution, signal-to-noise ratio and speed
title_sort long scan depth optical coherence tomography on imaging accommodation: impact of enhanced axial resolution, signal-to-noise ratio and speed
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6036665/
https://www.ncbi.nlm.nih.gov/pubmed/30003116
http://dx.doi.org/10.1186/s40662-018-0111-4
work_keys_str_mv AT shaoyilei longscandepthopticalcoherencetomographyonimagingaccommodationimpactofenhancedaxialresolutionsignaltonoiseratioandspeed
AT taoaizhu longscandepthopticalcoherencetomographyonimagingaccommodationimpactofenhancedaxialresolutionsignaltonoiseratioandspeed
AT jianghong longscandepthopticalcoherencetomographyonimagingaccommodationimpactofenhancedaxialresolutionsignaltonoiseratioandspeed
AT shenmeixiao longscandepthopticalcoherencetomographyonimagingaccommodationimpactofenhancedaxialresolutionsignaltonoiseratioandspeed
AT zhudexi longscandepthopticalcoherencetomographyonimagingaccommodationimpactofenhancedaxialresolutionsignaltonoiseratioandspeed
AT lufan longscandepthopticalcoherencetomographyonimagingaccommodationimpactofenhancedaxialresolutionsignaltonoiseratioandspeed
AT karpcaroll longscandepthopticalcoherencetomographyonimagingaccommodationimpactofenhancedaxialresolutionsignaltonoiseratioandspeed
AT yeyufeng longscandepthopticalcoherencetomographyonimagingaccommodationimpactofenhancedaxialresolutionsignaltonoiseratioandspeed
AT wangjianhua longscandepthopticalcoherencetomographyonimagingaccommodationimpactofenhancedaxialresolutionsignaltonoiseratioandspeed