Cargando…

Dosimetric Effects of Head and Neck Immobilization Devices on Multi-field Intensity Modulated Radiation Therapy for Nasopharyngeal Carcinoma

Background: In practice, the dose perturbation effect of head and neck immobilization devices is often overlooked in intensity-modulated radiation therapy (IMRT) for nasopharyngeal carcinoma (NPC). Purpose of this study is to verify and analyze the dosimetric effect of head and neck immobilization d...

Descripción completa

Detalles Bibliográficos
Autores principales: Chen, Li, Peng, Ying-Lin, Gu, Shi-Yong, Shen, Hui, Zhang, Dan-Dan, Sun, Wen-Zhao, Wu, Jian-Hua, Deng, Xiao-Wu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Ivyspring International Publisher 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6036882/
https://www.ncbi.nlm.nih.gov/pubmed/30026841
http://dx.doi.org/10.7150/jca.24887
_version_ 1783338244270718976
author Chen, Li
Peng, Ying-Lin
Gu, Shi-Yong
Shen, Hui
Zhang, Dan-Dan
Sun, Wen-Zhao
Wu, Jian-Hua
Deng, Xiao-Wu
author_facet Chen, Li
Peng, Ying-Lin
Gu, Shi-Yong
Shen, Hui
Zhang, Dan-Dan
Sun, Wen-Zhao
Wu, Jian-Hua
Deng, Xiao-Wu
author_sort Chen, Li
collection PubMed
description Background: In practice, the dose perturbation effect of head and neck immobilization devices is often overlooked in intensity-modulated radiation therapy (IMRT) for nasopharyngeal carcinoma (NPC). Purpose of this study is to verify and analyze the dosimetric effect of head and neck immobilization devices on NPC multi-field IMRT. Methods: Ten patients with nasopharyngeal carcinoma were randomly selected. Two sets of body contours were established for each patient. One set of body contours did not contain the immobilization device, and the other contour set included the immobilization device. For each patient, dose calculations were conducted for the two sets of contours using the same 9-field IMRT plan, which were recorded as Plan- and Plan+. The dose difference caused by the head and neck immobilization devices was assessed by comparing the dose-volume histogram (DVH) parameter results and by plan subtraction. The gafchromic EBT3 film and anthropomorphic phantom were used to verify the calculated doses. Results: The target coverage and average dose of Plan+ were lower than those of Plan- : the prescription dose coverage rates for PTVnx, PTVnd, PTV1 and PTV2 decreased by 2.4%, 9.9%, 1.5%, and 3.6%, respectively, and the mean doses were reduced by 0.9%, 1.9%, 1.1%, and 1.5%, respectively. Doses in the organs at risk showed no significant differences or slight reductions (the maximum reduction in mean dose was 1.7%). From the EBT3 measurements, the skin dose on the posterior neck was increased by approximately 53%. Conclusion: The attenuation and bolus effects of the head and neck immobilization device reduce dose coverage rate and average dose of the planning target volumes in nasopharyngeal carcinoma and lead to an increase in the skin dose. During treatment planning and dose calculation, the immobilization device should be included within body contour to account for the dose attenuation and skin dose increment.
format Online
Article
Text
id pubmed-6036882
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Ivyspring International Publisher
record_format MEDLINE/PubMed
spelling pubmed-60368822018-07-19 Dosimetric Effects of Head and Neck Immobilization Devices on Multi-field Intensity Modulated Radiation Therapy for Nasopharyngeal Carcinoma Chen, Li Peng, Ying-Lin Gu, Shi-Yong Shen, Hui Zhang, Dan-Dan Sun, Wen-Zhao Wu, Jian-Hua Deng, Xiao-Wu J Cancer Research Paper Background: In practice, the dose perturbation effect of head and neck immobilization devices is often overlooked in intensity-modulated radiation therapy (IMRT) for nasopharyngeal carcinoma (NPC). Purpose of this study is to verify and analyze the dosimetric effect of head and neck immobilization devices on NPC multi-field IMRT. Methods: Ten patients with nasopharyngeal carcinoma were randomly selected. Two sets of body contours were established for each patient. One set of body contours did not contain the immobilization device, and the other contour set included the immobilization device. For each patient, dose calculations were conducted for the two sets of contours using the same 9-field IMRT plan, which were recorded as Plan- and Plan+. The dose difference caused by the head and neck immobilization devices was assessed by comparing the dose-volume histogram (DVH) parameter results and by plan subtraction. The gafchromic EBT3 film and anthropomorphic phantom were used to verify the calculated doses. Results: The target coverage and average dose of Plan+ were lower than those of Plan- : the prescription dose coverage rates for PTVnx, PTVnd, PTV1 and PTV2 decreased by 2.4%, 9.9%, 1.5%, and 3.6%, respectively, and the mean doses were reduced by 0.9%, 1.9%, 1.1%, and 1.5%, respectively. Doses in the organs at risk showed no significant differences or slight reductions (the maximum reduction in mean dose was 1.7%). From the EBT3 measurements, the skin dose on the posterior neck was increased by approximately 53%. Conclusion: The attenuation and bolus effects of the head and neck immobilization device reduce dose coverage rate and average dose of the planning target volumes in nasopharyngeal carcinoma and lead to an increase in the skin dose. During treatment planning and dose calculation, the immobilization device should be included within body contour to account for the dose attenuation and skin dose increment. Ivyspring International Publisher 2018-06-14 /pmc/articles/PMC6036882/ /pubmed/30026841 http://dx.doi.org/10.7150/jca.24887 Text en © Ivyspring International Publisher This is an open access article distributed under the terms of the Creative Commons Attribution (CC BY-NC) license (https://creativecommons.org/licenses/by-nc/4.0/). See http://ivyspring.com/terms for full terms and conditions.
spellingShingle Research Paper
Chen, Li
Peng, Ying-Lin
Gu, Shi-Yong
Shen, Hui
Zhang, Dan-Dan
Sun, Wen-Zhao
Wu, Jian-Hua
Deng, Xiao-Wu
Dosimetric Effects of Head and Neck Immobilization Devices on Multi-field Intensity Modulated Radiation Therapy for Nasopharyngeal Carcinoma
title Dosimetric Effects of Head and Neck Immobilization Devices on Multi-field Intensity Modulated Radiation Therapy for Nasopharyngeal Carcinoma
title_full Dosimetric Effects of Head and Neck Immobilization Devices on Multi-field Intensity Modulated Radiation Therapy for Nasopharyngeal Carcinoma
title_fullStr Dosimetric Effects of Head and Neck Immobilization Devices on Multi-field Intensity Modulated Radiation Therapy for Nasopharyngeal Carcinoma
title_full_unstemmed Dosimetric Effects of Head and Neck Immobilization Devices on Multi-field Intensity Modulated Radiation Therapy for Nasopharyngeal Carcinoma
title_short Dosimetric Effects of Head and Neck Immobilization Devices on Multi-field Intensity Modulated Radiation Therapy for Nasopharyngeal Carcinoma
title_sort dosimetric effects of head and neck immobilization devices on multi-field intensity modulated radiation therapy for nasopharyngeal carcinoma
topic Research Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6036882/
https://www.ncbi.nlm.nih.gov/pubmed/30026841
http://dx.doi.org/10.7150/jca.24887
work_keys_str_mv AT chenli dosimetriceffectsofheadandneckimmobilizationdevicesonmultifieldintensitymodulatedradiationtherapyfornasopharyngealcarcinoma
AT pengyinglin dosimetriceffectsofheadandneckimmobilizationdevicesonmultifieldintensitymodulatedradiationtherapyfornasopharyngealcarcinoma
AT gushiyong dosimetriceffectsofheadandneckimmobilizationdevicesonmultifieldintensitymodulatedradiationtherapyfornasopharyngealcarcinoma
AT shenhui dosimetriceffectsofheadandneckimmobilizationdevicesonmultifieldintensitymodulatedradiationtherapyfornasopharyngealcarcinoma
AT zhangdandan dosimetriceffectsofheadandneckimmobilizationdevicesonmultifieldintensitymodulatedradiationtherapyfornasopharyngealcarcinoma
AT sunwenzhao dosimetriceffectsofheadandneckimmobilizationdevicesonmultifieldintensitymodulatedradiationtherapyfornasopharyngealcarcinoma
AT wujianhua dosimetriceffectsofheadandneckimmobilizationdevicesonmultifieldintensitymodulatedradiationtherapyfornasopharyngealcarcinoma
AT dengxiaowu dosimetriceffectsofheadandneckimmobilizationdevicesonmultifieldintensitymodulatedradiationtherapyfornasopharyngealcarcinoma