Cargando…
CT-based Navigation System Using a Patient-Specific Instrument for Femoral Component Positioning: An Experimental in vitro Study with a Sawbone Model
PURPOSE: The intraoperative version of the femoral component is usually determined by visual appraisal of the stem position relative to the distal femoral condylar axis. However, several studies have suggested that a surgeon's visual assessment of the stem position has a high probability of mis...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Yonsei University College of Medicine
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6037596/ https://www.ncbi.nlm.nih.gov/pubmed/29978614 http://dx.doi.org/10.3349/ymj.2018.59.6.769 |
_version_ | 1783338344057405440 |
---|---|
author | Lee, Seongpung Kim, Jun-Young Hong, Jaesung Baek, Seung-Hoon Kim, Shin-Yoon |
author_facet | Lee, Seongpung Kim, Jun-Young Hong, Jaesung Baek, Seung-Hoon Kim, Shin-Yoon |
author_sort | Lee, Seongpung |
collection | PubMed |
description | PURPOSE: The intraoperative version of the femoral component is usually determined by visual appraisal of the stem position relative to the distal femoral condylar axis. However, several studies have suggested that a surgeon's visual assessment of the stem position has a high probability of misinterpretation. We developed a computed tomography (CT)-based navigation system with a patient-specific instrument (PSI) capable of three-dimensional (3D) printing and investigated its accuracy and consistency in comparison to the conventional technique of visual assessment of the stem position. MATERIALS AND METHODS: A CT scan of a femur sawbone model was performed, and pre-experimental planning was completed. We conducted 30 femoral neck osteotomies using the conventional technique and another 30 femoral neck osteotomies using the proposed technique. The femoral medullary canals were identified in both groups using a box chisel. RESULTS: For the absolute deviation between the measured and planned values, the mean two-dimensional anteversions of the proposed and conventional techniques were 1.41° and 4.78°, while their mean 3D anteversions were 1.15° and 3.31°. The mean θ(1), θ(2), θ(3), and d, all of which are parameters for evaluating femoral neck osteotomy, were 2.93°, 1.96°, 5.29°, and 0.48 mm for the proposed technique and 4.26°, 3.17°, 4.43°, and 3.15 mm for the conventional technique, respectively. CONCLUSION: The CT-based navigation system with PSI was more accurate and consistent than the conventional technique for assessment of stem position. Therefore, it can be used to reduce the frequency of incorrect assessments of the stem position among surgeons and to help with accurate determination of stem anteversion. |
format | Online Article Text |
id | pubmed-6037596 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Yonsei University College of Medicine |
record_format | MEDLINE/PubMed |
spelling | pubmed-60375962018-08-01 CT-based Navigation System Using a Patient-Specific Instrument for Femoral Component Positioning: An Experimental in vitro Study with a Sawbone Model Lee, Seongpung Kim, Jun-Young Hong, Jaesung Baek, Seung-Hoon Kim, Shin-Yoon Yonsei Med J Original Article PURPOSE: The intraoperative version of the femoral component is usually determined by visual appraisal of the stem position relative to the distal femoral condylar axis. However, several studies have suggested that a surgeon's visual assessment of the stem position has a high probability of misinterpretation. We developed a computed tomography (CT)-based navigation system with a patient-specific instrument (PSI) capable of three-dimensional (3D) printing and investigated its accuracy and consistency in comparison to the conventional technique of visual assessment of the stem position. MATERIALS AND METHODS: A CT scan of a femur sawbone model was performed, and pre-experimental planning was completed. We conducted 30 femoral neck osteotomies using the conventional technique and another 30 femoral neck osteotomies using the proposed technique. The femoral medullary canals were identified in both groups using a box chisel. RESULTS: For the absolute deviation between the measured and planned values, the mean two-dimensional anteversions of the proposed and conventional techniques were 1.41° and 4.78°, while their mean 3D anteversions were 1.15° and 3.31°. The mean θ(1), θ(2), θ(3), and d, all of which are parameters for evaluating femoral neck osteotomy, were 2.93°, 1.96°, 5.29°, and 0.48 mm for the proposed technique and 4.26°, 3.17°, 4.43°, and 3.15 mm for the conventional technique, respectively. CONCLUSION: The CT-based navigation system with PSI was more accurate and consistent than the conventional technique for assessment of stem position. Therefore, it can be used to reduce the frequency of incorrect assessments of the stem position among surgeons and to help with accurate determination of stem anteversion. Yonsei University College of Medicine 2018-08-01 2018-07-04 /pmc/articles/PMC6037596/ /pubmed/29978614 http://dx.doi.org/10.3349/ymj.2018.59.6.769 Text en © Copyright: Yonsei University College of Medicine 2018 http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Lee, Seongpung Kim, Jun-Young Hong, Jaesung Baek, Seung-Hoon Kim, Shin-Yoon CT-based Navigation System Using a Patient-Specific Instrument for Femoral Component Positioning: An Experimental in vitro Study with a Sawbone Model |
title | CT-based Navigation System Using a Patient-Specific Instrument for Femoral Component Positioning: An Experimental in vitro Study with a Sawbone Model |
title_full | CT-based Navigation System Using a Patient-Specific Instrument for Femoral Component Positioning: An Experimental in vitro Study with a Sawbone Model |
title_fullStr | CT-based Navigation System Using a Patient-Specific Instrument for Femoral Component Positioning: An Experimental in vitro Study with a Sawbone Model |
title_full_unstemmed | CT-based Navigation System Using a Patient-Specific Instrument for Femoral Component Positioning: An Experimental in vitro Study with a Sawbone Model |
title_short | CT-based Navigation System Using a Patient-Specific Instrument for Femoral Component Positioning: An Experimental in vitro Study with a Sawbone Model |
title_sort | ct-based navigation system using a patient-specific instrument for femoral component positioning: an experimental in vitro study with a sawbone model |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6037596/ https://www.ncbi.nlm.nih.gov/pubmed/29978614 http://dx.doi.org/10.3349/ymj.2018.59.6.769 |
work_keys_str_mv | AT leeseongpung ctbasednavigationsystemusingapatientspecificinstrumentforfemoralcomponentpositioninganexperimentalinvitrostudywithasawbonemodel AT kimjunyoung ctbasednavigationsystemusingapatientspecificinstrumentforfemoralcomponentpositioninganexperimentalinvitrostudywithasawbonemodel AT hongjaesung ctbasednavigationsystemusingapatientspecificinstrumentforfemoralcomponentpositioninganexperimentalinvitrostudywithasawbonemodel AT baekseunghoon ctbasednavigationsystemusingapatientspecificinstrumentforfemoralcomponentpositioninganexperimentalinvitrostudywithasawbonemodel AT kimshinyoon ctbasednavigationsystemusingapatientspecificinstrumentforfemoralcomponentpositioninganexperimentalinvitrostudywithasawbonemodel |