Cargando…
The Predictive Value of SPECT/CT imaging in colorectal liver metastases response after (90)Y-radioembolization
The aim of this study was to evaluate a modified method of calculating the (99m)Tc/(90)Y tumor-to-normal-liver uptake ratio (mT/N) based on SPECT/CT imaging, for use in predicting the overall response of colorectal liver tumors after radioembolization. A modified phantom-based method of tumor-to-nor...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6039046/ https://www.ncbi.nlm.nih.gov/pubmed/29990342 http://dx.doi.org/10.1371/journal.pone.0200488 |
Sumario: | The aim of this study was to evaluate a modified method of calculating the (99m)Tc/(90)Y tumor-to-normal-liver uptake ratio (mT/N) based on SPECT/CT imaging, for use in predicting the overall response of colorectal liver tumors after radioembolization. A modified phantom-based method of tumor-to-normal-liver ratio calculation was proposed and assessed. In contrast to the traditional method based on data gathered from the whole tumor, gamma counts are collected only from a 2D region of interest delineated in the SPECT/CT section with the longest tumor diameter (as specified in RECIST 1.1). The modified tumor-to-normal-liver ratio (mT/N1) and (90)Y predicted tumor absorbed dose (PAD) were obtained based on (99m)Tc-MAA SPECT/CT, and similarly the modified tumor-to-normal-liver ratio (mT/N2) and (90)Y actual tumor absorbed dose (AAD) were calculated after (90)Y-SPECT/CT. Tumor response was assessed on follow-up CTs. Using the newly proposed method, a total of 103 liver colorectal metastases in 21 patients who underwent radioembolization (between June 2009 and October 2015) were evaluated in pre-treatment CT scans and (99m)Tc-MAA-SPECT/CT scans and compared with post-treatment (90)Y-SPECT/CT scans and follow-up CT scans. The results showed that the mT/N1 ratio (p = 0.012), PAD (p < 0.001) and AAD (p < 0.001) were predictors of tumor response after radioembolization. The time to progression was significantly lengthened for tumors with mT/N1 higher than 1.7 or PAD higher than 70 Gy. The risk of progression for tumors with mT/N1 lower than 1.7 or PAD below 70 Gy was significantly higher. The mT/N2 ratio had no significant correlation with treatment results. CONCLUSION: The mT/N1 ratio, PAD, and AAD can be used as predictors of tumor response to SIRT treatment, and SPECT/CT imaging can be used for dosimetric assessment of radioembolization. |
---|