Using Sigma metrics to establish analytical product performance requirements and optimize analytical performance of an in vitro diagnostic assay using a theoretical total PSA assay as an example
INTRODUCTION: Establishing analytical performance requirements for in vitro diagnostic (IVD) assays is a challenging process. Manufacturers try to optimize analytical performance by choosing amongst many combinations of different product performance characteristics. Sigma metrics and method decision...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Croatian Society of Medical Biochemistry and Laboratory Medicine
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6039165/ https://www.ncbi.nlm.nih.gov/pubmed/30022889 http://dx.doi.org/10.11613/BM.2018.020903 |
_version_ | 1783338632044609536 |
---|---|
author | Petrides, Victoria Schneider, Sharon |
author_facet | Petrides, Victoria Schneider, Sharon |
author_sort | Petrides, Victoria |
collection | PubMed |
description | INTRODUCTION: Establishing analytical performance requirements for in vitro diagnostic (IVD) assays is a challenging process. Manufacturers try to optimize analytical performance by choosing amongst many combinations of different product performance characteristics. Sigma metrics and method decision charts can be helpful aids in choosing appropriate analytical performance requirements. The objective of this research was to demonstrate the use of Sigma metrics and method decision charts to help establish analytical performance requirements and to optimize analytical performance at medical decision concentrations for an IVD assay. MATERIALS AND METHODS: A range of possible Sigma metrics were determined using three sources for total allowable error (TEa) and hypothetical total PSA assay results. Method decision charts were created for each TEa source and used to identify the maximum precision and bias that the assay could have to maintain sigma level performance of at least 3. RESULTS: To achieve a sigma performance level of at least 3 for a hypothetical total PSA assay, the maximum allowable coefficient of variation ranged from 5.0% to 11.2% depending on the TEa source. To achieve a sigma performance level of at least 6, the maximum allowable coefficient of variation ranged from 2.5% to 5.6% depending on the TEa source. CONCLUSIONS: Using Sigma metrics and method decision charts when establishing analytical performance requirements can help manufacturers choose product requirements that will optimize IVD assay product performance. |
format | Online Article Text |
id | pubmed-6039165 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Croatian Society of Medical Biochemistry and Laboratory Medicine |
record_format | MEDLINE/PubMed |
spelling | pubmed-60391652018-07-18 Using Sigma metrics to establish analytical product performance requirements and optimize analytical performance of an in vitro diagnostic assay using a theoretical total PSA assay as an example Petrides, Victoria Schneider, Sharon Biochem Med (Zagreb) Short Communications INTRODUCTION: Establishing analytical performance requirements for in vitro diagnostic (IVD) assays is a challenging process. Manufacturers try to optimize analytical performance by choosing amongst many combinations of different product performance characteristics. Sigma metrics and method decision charts can be helpful aids in choosing appropriate analytical performance requirements. The objective of this research was to demonstrate the use of Sigma metrics and method decision charts to help establish analytical performance requirements and to optimize analytical performance at medical decision concentrations for an IVD assay. MATERIALS AND METHODS: A range of possible Sigma metrics were determined using three sources for total allowable error (TEa) and hypothetical total PSA assay results. Method decision charts were created for each TEa source and used to identify the maximum precision and bias that the assay could have to maintain sigma level performance of at least 3. RESULTS: To achieve a sigma performance level of at least 3 for a hypothetical total PSA assay, the maximum allowable coefficient of variation ranged from 5.0% to 11.2% depending on the TEa source. To achieve a sigma performance level of at least 6, the maximum allowable coefficient of variation ranged from 2.5% to 5.6% depending on the TEa source. CONCLUSIONS: Using Sigma metrics and method decision charts when establishing analytical performance requirements can help manufacturers choose product requirements that will optimize IVD assay product performance. Croatian Society of Medical Biochemistry and Laboratory Medicine 2018-06-15 2018-06-15 /pmc/articles/PMC6039165/ /pubmed/30022889 http://dx.doi.org/10.11613/BM.2018.020903 Text en ©Croatian Society of Medical Biochemistry and Laboratory Medicine. This is an Open Access article distributed under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Short Communications Petrides, Victoria Schneider, Sharon Using Sigma metrics to establish analytical product performance requirements and optimize analytical performance of an in vitro diagnostic assay using a theoretical total PSA assay as an example |
title | Using Sigma metrics to establish analytical product performance requirements and optimize analytical performance of an in vitro diagnostic assay using a theoretical total PSA assay as an example |
title_full | Using Sigma metrics to establish analytical product performance requirements and optimize analytical performance of an in vitro diagnostic assay using a theoretical total PSA assay as an example |
title_fullStr | Using Sigma metrics to establish analytical product performance requirements and optimize analytical performance of an in vitro diagnostic assay using a theoretical total PSA assay as an example |
title_full_unstemmed | Using Sigma metrics to establish analytical product performance requirements and optimize analytical performance of an in vitro diagnostic assay using a theoretical total PSA assay as an example |
title_short | Using Sigma metrics to establish analytical product performance requirements and optimize analytical performance of an in vitro diagnostic assay using a theoretical total PSA assay as an example |
title_sort | using sigma metrics to establish analytical product performance requirements and optimize analytical performance of an in vitro diagnostic assay using a theoretical total psa assay as an example |
topic | Short Communications |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6039165/ https://www.ncbi.nlm.nih.gov/pubmed/30022889 http://dx.doi.org/10.11613/BM.2018.020903 |
work_keys_str_mv | AT petridesvictoria usingsigmametricstoestablishanalyticalproductperformancerequirementsandoptimizeanalyticalperformanceofaninvitrodiagnosticassayusingatheoreticaltotalpsaassayasanexample AT schneidersharon usingsigmametricstoestablishanalyticalproductperformancerequirementsandoptimizeanalyticalperformanceofaninvitrodiagnosticassayusingatheoreticaltotalpsaassayasanexample |