Cargando…
Descemet membrane endothelial keratoplasty using ophthalmic viscoelastic devices for eyes with laser iridotomy-induced corneal endothelial decompensation: Analysis of 11 eyes
Graft insertion into the anterior chamber is one of the most important procedures for successful Descemet membrane endothelial keratoplasty (DMEK). Especially in eyes with fragile zonular fibers and a shallow anterior chamber, smooth graft insertion tends to become more difficult. Ophthalmic viscoel...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer Health
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6039634/ https://www.ncbi.nlm.nih.gov/pubmed/29952990 http://dx.doi.org/10.1097/MD.0000000000011245 |
_version_ | 1783338715723071488 |
---|---|
author | Hayashi, Takahiko Oyakawa, Itaru Matsuzawa, Akiko Yuda, Kentaro Shimizu, Toshiki Tsuchiya, Ayako Mizuki, Nobuhisa Kato, Naoko |
author_facet | Hayashi, Takahiko Oyakawa, Itaru Matsuzawa, Akiko Yuda, Kentaro Shimizu, Toshiki Tsuchiya, Ayako Mizuki, Nobuhisa Kato, Naoko |
author_sort | Hayashi, Takahiko |
collection | PubMed |
description | Graft insertion into the anterior chamber is one of the most important procedures for successful Descemet membrane endothelial keratoplasty (DMEK). Especially in eyes with fragile zonular fibers and a shallow anterior chamber, smooth graft insertion tends to become more difficult. Ophthalmic viscoelastic devices (OVDs) can usually help to retain the space in the anterior chamber and to improve the safety of manipulations during various ophthalmic surgeries. Therefore, we postulated that graft insertion into the anterior chamber could be improved by their use. The purpose of this study is to investigate the availability and efficacy of OVDs during graft insertion in DMEK surgery. A total of 11 eyes of 9 patients with bullous keratopathy who underwent DMEK were retrospectively analyzed. The cause of bullous keratopathy was corneal endothelial decompensation following laser iridotomy in all eyes. We used low viscous dispersive OVD (Opegan) to maintain the anterior chamber depth during graft insertion in all of the eyes. The graft insertion was uneventful in all of the eyes. The inserted graft was attached to the back surface of the cornea. However, 2 eyes needed rebubbling, and after rebubbling, all of the 2 grafts completely attached to the back surface of the cornea. The best spectacle-corrected visual acuity significantly improved 6 months after surgery (P < .001) and the central corneal thickness significantly decreased (P < .001). The use of OVD facilitates safer graft insertion during DMEK, and subsequently prevents endothelial cell loss, which leads to a successful procedure. |
format | Online Article Text |
id | pubmed-6039634 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Wolters Kluwer Health |
record_format | MEDLINE/PubMed |
spelling | pubmed-60396342018-07-16 Descemet membrane endothelial keratoplasty using ophthalmic viscoelastic devices for eyes with laser iridotomy-induced corneal endothelial decompensation: Analysis of 11 eyes Hayashi, Takahiko Oyakawa, Itaru Matsuzawa, Akiko Yuda, Kentaro Shimizu, Toshiki Tsuchiya, Ayako Mizuki, Nobuhisa Kato, Naoko Medicine (Baltimore) Research Article Graft insertion into the anterior chamber is one of the most important procedures for successful Descemet membrane endothelial keratoplasty (DMEK). Especially in eyes with fragile zonular fibers and a shallow anterior chamber, smooth graft insertion tends to become more difficult. Ophthalmic viscoelastic devices (OVDs) can usually help to retain the space in the anterior chamber and to improve the safety of manipulations during various ophthalmic surgeries. Therefore, we postulated that graft insertion into the anterior chamber could be improved by their use. The purpose of this study is to investigate the availability and efficacy of OVDs during graft insertion in DMEK surgery. A total of 11 eyes of 9 patients with bullous keratopathy who underwent DMEK were retrospectively analyzed. The cause of bullous keratopathy was corneal endothelial decompensation following laser iridotomy in all eyes. We used low viscous dispersive OVD (Opegan) to maintain the anterior chamber depth during graft insertion in all of the eyes. The graft insertion was uneventful in all of the eyes. The inserted graft was attached to the back surface of the cornea. However, 2 eyes needed rebubbling, and after rebubbling, all of the 2 grafts completely attached to the back surface of the cornea. The best spectacle-corrected visual acuity significantly improved 6 months after surgery (P < .001) and the central corneal thickness significantly decreased (P < .001). The use of OVD facilitates safer graft insertion during DMEK, and subsequently prevents endothelial cell loss, which leads to a successful procedure. Wolters Kluwer Health 2018-06-29 /pmc/articles/PMC6039634/ /pubmed/29952990 http://dx.doi.org/10.1097/MD.0000000000011245 Text en Copyright © 2018 the Author(s). Published by Wolters Kluwer Health, Inc. http://creativecommons.org/licenses/by-nd/4.0 This is an open access article distributed under the Creative Commons Attribution-NoDerivatives License 4.0, which allows for redistribution, commercial and non-commercial, as long as it is passed along unchanged and in whole, with credit to the author. http://creativecommons.org/licenses/by-nd/4.0 |
spellingShingle | Research Article Hayashi, Takahiko Oyakawa, Itaru Matsuzawa, Akiko Yuda, Kentaro Shimizu, Toshiki Tsuchiya, Ayako Mizuki, Nobuhisa Kato, Naoko Descemet membrane endothelial keratoplasty using ophthalmic viscoelastic devices for eyes with laser iridotomy-induced corneal endothelial decompensation: Analysis of 11 eyes |
title | Descemet membrane endothelial keratoplasty using ophthalmic viscoelastic devices for eyes with laser iridotomy-induced corneal endothelial decompensation: Analysis of 11 eyes |
title_full | Descemet membrane endothelial keratoplasty using ophthalmic viscoelastic devices for eyes with laser iridotomy-induced corneal endothelial decompensation: Analysis of 11 eyes |
title_fullStr | Descemet membrane endothelial keratoplasty using ophthalmic viscoelastic devices for eyes with laser iridotomy-induced corneal endothelial decompensation: Analysis of 11 eyes |
title_full_unstemmed | Descemet membrane endothelial keratoplasty using ophthalmic viscoelastic devices for eyes with laser iridotomy-induced corneal endothelial decompensation: Analysis of 11 eyes |
title_short | Descemet membrane endothelial keratoplasty using ophthalmic viscoelastic devices for eyes with laser iridotomy-induced corneal endothelial decompensation: Analysis of 11 eyes |
title_sort | descemet membrane endothelial keratoplasty using ophthalmic viscoelastic devices for eyes with laser iridotomy-induced corneal endothelial decompensation: analysis of 11 eyes |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6039634/ https://www.ncbi.nlm.nih.gov/pubmed/29952990 http://dx.doi.org/10.1097/MD.0000000000011245 |
work_keys_str_mv | AT hayashitakahiko descemetmembraneendothelialkeratoplastyusingophthalmicviscoelasticdevicesforeyeswithlaseriridotomyinducedcornealendothelialdecompensationanalysisof11eyes AT oyakawaitaru descemetmembraneendothelialkeratoplastyusingophthalmicviscoelasticdevicesforeyeswithlaseriridotomyinducedcornealendothelialdecompensationanalysisof11eyes AT matsuzawaakiko descemetmembraneendothelialkeratoplastyusingophthalmicviscoelasticdevicesforeyeswithlaseriridotomyinducedcornealendothelialdecompensationanalysisof11eyes AT yudakentaro descemetmembraneendothelialkeratoplastyusingophthalmicviscoelasticdevicesforeyeswithlaseriridotomyinducedcornealendothelialdecompensationanalysisof11eyes AT shimizutoshiki descemetmembraneendothelialkeratoplastyusingophthalmicviscoelasticdevicesforeyeswithlaseriridotomyinducedcornealendothelialdecompensationanalysisof11eyes AT tsuchiyaayako descemetmembraneendothelialkeratoplastyusingophthalmicviscoelasticdevicesforeyeswithlaseriridotomyinducedcornealendothelialdecompensationanalysisof11eyes AT mizukinobuhisa descemetmembraneendothelialkeratoplastyusingophthalmicviscoelasticdevicesforeyeswithlaseriridotomyinducedcornealendothelialdecompensationanalysisof11eyes AT katonaoko descemetmembraneendothelialkeratoplastyusingophthalmicviscoelasticdevicesforeyeswithlaseriridotomyinducedcornealendothelialdecompensationanalysisof11eyes |