Extent and location of fixation affects the biomechanical stability of short- or long-segment pedicle screw technique with screwing of fractured vertebra for the treatment of thoracolumbar burst fractures: An observational study using finite element analysis

Intermediate screw fixation at the fracture level has been widely accepted to treat thoracolumbar burst fractures, but no study has shown the effect of the extent and location of fixation. The effect of the extent and location of fixation on short- or long-segment pedicle screw fixation through inte...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Hongwei, Mo, Zhongjun, Han, Jianda, Liu, Jun, Li, Changqing, Zhou, Yue, Xiang, Liangbi, Yang, Lei
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer Health 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6039687/
https://www.ncbi.nlm.nih.gov/pubmed/29952989
http://dx.doi.org/10.1097/MD.0000000000011244
_version_ 1783338723872604160
author Wang, Hongwei
Mo, Zhongjun
Han, Jianda
Liu, Jun
Li, Changqing
Zhou, Yue
Xiang, Liangbi
Yang, Lei
author_facet Wang, Hongwei
Mo, Zhongjun
Han, Jianda
Liu, Jun
Li, Changqing
Zhou, Yue
Xiang, Liangbi
Yang, Lei
author_sort Wang, Hongwei
collection PubMed
description Intermediate screw fixation at the fracture level has been widely accepted to treat thoracolumbar burst fractures, but no study has shown the effect of the extent and location of fixation. The effect of the extent and location of fixation on short- or long-segment pedicle screw fixation through intermediate screw fixation at the fracture level in the treatment of thoracolumbar burst fractures is discussed. Posterior intermediate screw fixation techniques in treating T12 vertebral fracture models were simulated and compared using finite element methods; the fixation techniques included M3-L1 (bilateral 3 monoaxial pedicle screw fixation from L1 to T11), M3-L2, M4-L1 (bilateral 4 monoaxial pedicle screw fixation from L1 to T10), M4-L2, M4-L3, and M5-L2 (bilateral 5 monoaxial pedicle screw fixation from L2 to T10). Range of motion (ROM) and largest von Mises stress (LVMS) of the instrumentations were recorded and analyzed. No significant differences were observed in the mean ROM of all states of motion between the M3-L1 model and the other fixation models except for M5-L2. The LVMS of the pedicle screws and rods all occurred during flexion. The LVMS values of the pedicle screws were larger in the M3-L2 fixation model and M4-L3 fixation model than in the other fixation models. The M3-L1 model presented a significantly smaller mean LVMS of the pedicle screws in all states of motion than the M3-L2 model (P = .026). The LVMS values of the rods were larger in the M3-L2 fixation model, M4-L3 fixation model, and M4-L2 fixation model than in the other fixation models. No significant differences were observed in the mean LVMS of the rods in all states of motion among all the fixation models. When choosing short-segment pedicle screw fixation with the screwing of fractured vertebrae to treat thoracolumbar fractures, we suggest M3-L1 over M3-L2. More severe injuries can be considered to identify an alternative treatment to long-segment monoaxial pedicle fixation constructs such as the M4-L1 and M5-L2 techniques.
format Online
Article
Text
id pubmed-6039687
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Wolters Kluwer Health
record_format MEDLINE/PubMed
spelling pubmed-60396872018-07-16 Extent and location of fixation affects the biomechanical stability of short- or long-segment pedicle screw technique with screwing of fractured vertebra for the treatment of thoracolumbar burst fractures: An observational study using finite element analysis Wang, Hongwei Mo, Zhongjun Han, Jianda Liu, Jun Li, Changqing Zhou, Yue Xiang, Liangbi Yang, Lei Medicine (Baltimore) Research Article Intermediate screw fixation at the fracture level has been widely accepted to treat thoracolumbar burst fractures, but no study has shown the effect of the extent and location of fixation. The effect of the extent and location of fixation on short- or long-segment pedicle screw fixation through intermediate screw fixation at the fracture level in the treatment of thoracolumbar burst fractures is discussed. Posterior intermediate screw fixation techniques in treating T12 vertebral fracture models were simulated and compared using finite element methods; the fixation techniques included M3-L1 (bilateral 3 monoaxial pedicle screw fixation from L1 to T11), M3-L2, M4-L1 (bilateral 4 monoaxial pedicle screw fixation from L1 to T10), M4-L2, M4-L3, and M5-L2 (bilateral 5 monoaxial pedicle screw fixation from L2 to T10). Range of motion (ROM) and largest von Mises stress (LVMS) of the instrumentations were recorded and analyzed. No significant differences were observed in the mean ROM of all states of motion between the M3-L1 model and the other fixation models except for M5-L2. The LVMS of the pedicle screws and rods all occurred during flexion. The LVMS values of the pedicle screws were larger in the M3-L2 fixation model and M4-L3 fixation model than in the other fixation models. The M3-L1 model presented a significantly smaller mean LVMS of the pedicle screws in all states of motion than the M3-L2 model (P = .026). The LVMS values of the rods were larger in the M3-L2 fixation model, M4-L3 fixation model, and M4-L2 fixation model than in the other fixation models. No significant differences were observed in the mean LVMS of the rods in all states of motion among all the fixation models. When choosing short-segment pedicle screw fixation with the screwing of fractured vertebrae to treat thoracolumbar fractures, we suggest M3-L1 over M3-L2. More severe injuries can be considered to identify an alternative treatment to long-segment monoaxial pedicle fixation constructs such as the M4-L1 and M5-L2 techniques. Wolters Kluwer Health 2018-06-29 /pmc/articles/PMC6039687/ /pubmed/29952989 http://dx.doi.org/10.1097/MD.0000000000011244 Text en Copyright © 2018 the Author(s). Published by Wolters Kluwer Health, Inc. http://creativecommons.org/licenses/by-nc-nd/4.0 This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc-nd/4.0
spellingShingle Research Article
Wang, Hongwei
Mo, Zhongjun
Han, Jianda
Liu, Jun
Li, Changqing
Zhou, Yue
Xiang, Liangbi
Yang, Lei
Extent and location of fixation affects the biomechanical stability of short- or long-segment pedicle screw technique with screwing of fractured vertebra for the treatment of thoracolumbar burst fractures: An observational study using finite element analysis
title Extent and location of fixation affects the biomechanical stability of short- or long-segment pedicle screw technique with screwing of fractured vertebra for the treatment of thoracolumbar burst fractures: An observational study using finite element analysis
title_full Extent and location of fixation affects the biomechanical stability of short- or long-segment pedicle screw technique with screwing of fractured vertebra for the treatment of thoracolumbar burst fractures: An observational study using finite element analysis
title_fullStr Extent and location of fixation affects the biomechanical stability of short- or long-segment pedicle screw technique with screwing of fractured vertebra for the treatment of thoracolumbar burst fractures: An observational study using finite element analysis
title_full_unstemmed Extent and location of fixation affects the biomechanical stability of short- or long-segment pedicle screw technique with screwing of fractured vertebra for the treatment of thoracolumbar burst fractures: An observational study using finite element analysis
title_short Extent and location of fixation affects the biomechanical stability of short- or long-segment pedicle screw technique with screwing of fractured vertebra for the treatment of thoracolumbar burst fractures: An observational study using finite element analysis
title_sort extent and location of fixation affects the biomechanical stability of short- or long-segment pedicle screw technique with screwing of fractured vertebra for the treatment of thoracolumbar burst fractures: an observational study using finite element analysis
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6039687/
https://www.ncbi.nlm.nih.gov/pubmed/29952989
http://dx.doi.org/10.1097/MD.0000000000011244
work_keys_str_mv AT wanghongwei extentandlocationoffixationaffectsthebiomechanicalstabilityofshortorlongsegmentpediclescrewtechniquewithscrewingoffracturedvertebraforthetreatmentofthoracolumbarburstfracturesanobservationalstudyusingfiniteelementanalysis
AT mozhongjun extentandlocationoffixationaffectsthebiomechanicalstabilityofshortorlongsegmentpediclescrewtechniquewithscrewingoffracturedvertebraforthetreatmentofthoracolumbarburstfracturesanobservationalstudyusingfiniteelementanalysis
AT hanjianda extentandlocationoffixationaffectsthebiomechanicalstabilityofshortorlongsegmentpediclescrewtechniquewithscrewingoffracturedvertebraforthetreatmentofthoracolumbarburstfracturesanobservationalstudyusingfiniteelementanalysis
AT liujun extentandlocationoffixationaffectsthebiomechanicalstabilityofshortorlongsegmentpediclescrewtechniquewithscrewingoffracturedvertebraforthetreatmentofthoracolumbarburstfracturesanobservationalstudyusingfiniteelementanalysis
AT lichangqing extentandlocationoffixationaffectsthebiomechanicalstabilityofshortorlongsegmentpediclescrewtechniquewithscrewingoffracturedvertebraforthetreatmentofthoracolumbarburstfracturesanobservationalstudyusingfiniteelementanalysis
AT zhouyue extentandlocationoffixationaffectsthebiomechanicalstabilityofshortorlongsegmentpediclescrewtechniquewithscrewingoffracturedvertebraforthetreatmentofthoracolumbarburstfracturesanobservationalstudyusingfiniteelementanalysis
AT xiangliangbi extentandlocationoffixationaffectsthebiomechanicalstabilityofshortorlongsegmentpediclescrewtechniquewithscrewingoffracturedvertebraforthetreatmentofthoracolumbarburstfracturesanobservationalstudyusingfiniteelementanalysis
AT yanglei extentandlocationoffixationaffectsthebiomechanicalstabilityofshortorlongsegmentpediclescrewtechniquewithscrewingoffracturedvertebraforthetreatmentofthoracolumbarburstfracturesanobservationalstudyusingfiniteelementanalysis