Cargando…
Quantitation Error in (1)H MRS Caused by B(1) Inhomogeneity and Chemical Shift Displacement
PURPOSE: The quantitation accuracy in proton magnetic resonance spectroscopy ((1)H MRS) improves at higher B(0) field. However, a larger chemical shift displacement (CSD) and stronger B(1) inhomogeneity exist. In this work, we evaluate the quantitation accuracy for the spectra of metabolite mixtures...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Japanese Society for Magnetic Resonance in Medicine
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6039773/ https://www.ncbi.nlm.nih.gov/pubmed/29118306 http://dx.doi.org/10.2463/mrms.mp.2017-0062 |
_version_ | 1783338742254141440 |
---|---|
author | Watanabe, Hidehiro Takaya, Nobuhiro |
author_facet | Watanabe, Hidehiro Takaya, Nobuhiro |
author_sort | Watanabe, Hidehiro |
collection | PubMed |
description | PURPOSE: The quantitation accuracy in proton magnetic resonance spectroscopy ((1)H MRS) improves at higher B(0) field. However, a larger chemical shift displacement (CSD) and stronger B(1) inhomogeneity exist. In this work, we evaluate the quantitation accuracy for the spectra of metabolite mixtures in phantom experiments at 4.7T. We demonstrate a position-dependent error in quantitation and propose a correction method by measuring water signals. MATERIALS AND METHODS: All experiments were conducted on a whole-body 4.7T MR system with a quadrature volume coil for transmission and reception. We arranged three bottles filled with metabolite solutions of N-acetyl aspartate (NAA) and creatine (Cr) in a vertical row inside a cylindrical phantom filled with water. Peak areas of three singlets of NAA and Cr were measured on three (1)H spectra at three volume of interests (VOIs) inside three bottles. We also measured a series of water spectra with a shifted carrier frequency and measured a reception sensitivity map. RESULTS: The ratios of NAA and Cr at 3.92 ppm to Cr at 3.01 ppm differed amongst the three VOIs in peak area, which leads to a position-dependent error. The nature of slope depicting the relationship between peak areas and the shifted values of frequency was like that between the reception sensitivities and displacement at every VOI. CONCLUSION: CSD and inhomogeneity of reception sensitivity cause amplitude modulation along the direction of chemical shift on the spectra, resulting in a quantitation error. This error may be more significant at higher B(0) field where CSD and B(1) inhomogeneity are more severe. This error may also occur in reception using a surface coil having inhomogeneous B(1). Since this type of error is around a few percent, the data should be analyzed with greater attention while discussing small differences in the studies of (1)H MRS. |
format | Online Article Text |
id | pubmed-6039773 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Japanese Society for Magnetic Resonance in Medicine |
record_format | MEDLINE/PubMed |
spelling | pubmed-60397732018-07-20 Quantitation Error in (1)H MRS Caused by B(1) Inhomogeneity and Chemical Shift Displacement Watanabe, Hidehiro Takaya, Nobuhiro Magn Reson Med Sci Major Paper PURPOSE: The quantitation accuracy in proton magnetic resonance spectroscopy ((1)H MRS) improves at higher B(0) field. However, a larger chemical shift displacement (CSD) and stronger B(1) inhomogeneity exist. In this work, we evaluate the quantitation accuracy for the spectra of metabolite mixtures in phantom experiments at 4.7T. We demonstrate a position-dependent error in quantitation and propose a correction method by measuring water signals. MATERIALS AND METHODS: All experiments were conducted on a whole-body 4.7T MR system with a quadrature volume coil for transmission and reception. We arranged three bottles filled with metabolite solutions of N-acetyl aspartate (NAA) and creatine (Cr) in a vertical row inside a cylindrical phantom filled with water. Peak areas of three singlets of NAA and Cr were measured on three (1)H spectra at three volume of interests (VOIs) inside three bottles. We also measured a series of water spectra with a shifted carrier frequency and measured a reception sensitivity map. RESULTS: The ratios of NAA and Cr at 3.92 ppm to Cr at 3.01 ppm differed amongst the three VOIs in peak area, which leads to a position-dependent error. The nature of slope depicting the relationship between peak areas and the shifted values of frequency was like that between the reception sensitivities and displacement at every VOI. CONCLUSION: CSD and inhomogeneity of reception sensitivity cause amplitude modulation along the direction of chemical shift on the spectra, resulting in a quantitation error. This error may be more significant at higher B(0) field where CSD and B(1) inhomogeneity are more severe. This error may also occur in reception using a surface coil having inhomogeneous B(1). Since this type of error is around a few percent, the data should be analyzed with greater attention while discussing small differences in the studies of (1)H MRS. Japanese Society for Magnetic Resonance in Medicine 2017-11-08 /pmc/articles/PMC6039773/ /pubmed/29118306 http://dx.doi.org/10.2463/mrms.mp.2017-0062 Text en © 2017 Japanese Society for Magnetic Resonance in Medicine This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License. To view a copy of this license, visit http://creativecommons.org/licenses/by-nc-nd/4.0/ |
spellingShingle | Major Paper Watanabe, Hidehiro Takaya, Nobuhiro Quantitation Error in (1)H MRS Caused by B(1) Inhomogeneity and Chemical Shift Displacement |
title | Quantitation Error in (1)H MRS Caused by B(1) Inhomogeneity and Chemical Shift Displacement |
title_full | Quantitation Error in (1)H MRS Caused by B(1) Inhomogeneity and Chemical Shift Displacement |
title_fullStr | Quantitation Error in (1)H MRS Caused by B(1) Inhomogeneity and Chemical Shift Displacement |
title_full_unstemmed | Quantitation Error in (1)H MRS Caused by B(1) Inhomogeneity and Chemical Shift Displacement |
title_short | Quantitation Error in (1)H MRS Caused by B(1) Inhomogeneity and Chemical Shift Displacement |
title_sort | quantitation error in (1)h mrs caused by b(1) inhomogeneity and chemical shift displacement |
topic | Major Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6039773/ https://www.ncbi.nlm.nih.gov/pubmed/29118306 http://dx.doi.org/10.2463/mrms.mp.2017-0062 |
work_keys_str_mv | AT watanabehidehiro quantitationerrorin1hmrscausedbyb1inhomogeneityandchemicalshiftdisplacement AT takayanobuhiro quantitationerrorin1hmrscausedbyb1inhomogeneityandchemicalshiftdisplacement |