Cargando…

Quantitation Error in (1)H MRS Caused by B(1) Inhomogeneity and Chemical Shift Displacement

PURPOSE: The quantitation accuracy in proton magnetic resonance spectroscopy ((1)H MRS) improves at higher B(0) field. However, a larger chemical shift displacement (CSD) and stronger B(1) inhomogeneity exist. In this work, we evaluate the quantitation accuracy for the spectra of metabolite mixtures...

Descripción completa

Detalles Bibliográficos
Autores principales: Watanabe, Hidehiro, Takaya, Nobuhiro
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Japanese Society for Magnetic Resonance in Medicine 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6039773/
https://www.ncbi.nlm.nih.gov/pubmed/29118306
http://dx.doi.org/10.2463/mrms.mp.2017-0062
_version_ 1783338742254141440
author Watanabe, Hidehiro
Takaya, Nobuhiro
author_facet Watanabe, Hidehiro
Takaya, Nobuhiro
author_sort Watanabe, Hidehiro
collection PubMed
description PURPOSE: The quantitation accuracy in proton magnetic resonance spectroscopy ((1)H MRS) improves at higher B(0) field. However, a larger chemical shift displacement (CSD) and stronger B(1) inhomogeneity exist. In this work, we evaluate the quantitation accuracy for the spectra of metabolite mixtures in phantom experiments at 4.7T. We demonstrate a position-dependent error in quantitation and propose a correction method by measuring water signals. MATERIALS AND METHODS: All experiments were conducted on a whole-body 4.7T MR system with a quadrature volume coil for transmission and reception. We arranged three bottles filled with metabolite solutions of N-acetyl aspartate (NAA) and creatine (Cr) in a vertical row inside a cylindrical phantom filled with water. Peak areas of three singlets of NAA and Cr were measured on three (1)H spectra at three volume of interests (VOIs) inside three bottles. We also measured a series of water spectra with a shifted carrier frequency and measured a reception sensitivity map. RESULTS: The ratios of NAA and Cr at 3.92 ppm to Cr at 3.01 ppm differed amongst the three VOIs in peak area, which leads to a position-dependent error. The nature of slope depicting the relationship between peak areas and the shifted values of frequency was like that between the reception sensitivities and displacement at every VOI. CONCLUSION: CSD and inhomogeneity of reception sensitivity cause amplitude modulation along the direction of chemical shift on the spectra, resulting in a quantitation error. This error may be more significant at higher B(0) field where CSD and B(1) inhomogeneity are more severe. This error may also occur in reception using a surface coil having inhomogeneous B(1). Since this type of error is around a few percent, the data should be analyzed with greater attention while discussing small differences in the studies of (1)H MRS.
format Online
Article
Text
id pubmed-6039773
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Japanese Society for Magnetic Resonance in Medicine
record_format MEDLINE/PubMed
spelling pubmed-60397732018-07-20 Quantitation Error in (1)H MRS Caused by B(1) Inhomogeneity and Chemical Shift Displacement Watanabe, Hidehiro Takaya, Nobuhiro Magn Reson Med Sci Major Paper PURPOSE: The quantitation accuracy in proton magnetic resonance spectroscopy ((1)H MRS) improves at higher B(0) field. However, a larger chemical shift displacement (CSD) and stronger B(1) inhomogeneity exist. In this work, we evaluate the quantitation accuracy for the spectra of metabolite mixtures in phantom experiments at 4.7T. We demonstrate a position-dependent error in quantitation and propose a correction method by measuring water signals. MATERIALS AND METHODS: All experiments were conducted on a whole-body 4.7T MR system with a quadrature volume coil for transmission and reception. We arranged three bottles filled with metabolite solutions of N-acetyl aspartate (NAA) and creatine (Cr) in a vertical row inside a cylindrical phantom filled with water. Peak areas of three singlets of NAA and Cr were measured on three (1)H spectra at three volume of interests (VOIs) inside three bottles. We also measured a series of water spectra with a shifted carrier frequency and measured a reception sensitivity map. RESULTS: The ratios of NAA and Cr at 3.92 ppm to Cr at 3.01 ppm differed amongst the three VOIs in peak area, which leads to a position-dependent error. The nature of slope depicting the relationship between peak areas and the shifted values of frequency was like that between the reception sensitivities and displacement at every VOI. CONCLUSION: CSD and inhomogeneity of reception sensitivity cause amplitude modulation along the direction of chemical shift on the spectra, resulting in a quantitation error. This error may be more significant at higher B(0) field where CSD and B(1) inhomogeneity are more severe. This error may also occur in reception using a surface coil having inhomogeneous B(1). Since this type of error is around a few percent, the data should be analyzed with greater attention while discussing small differences in the studies of (1)H MRS. Japanese Society for Magnetic Resonance in Medicine 2017-11-08 /pmc/articles/PMC6039773/ /pubmed/29118306 http://dx.doi.org/10.2463/mrms.mp.2017-0062 Text en © 2017 Japanese Society for Magnetic Resonance in Medicine This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License. To view a copy of this license, visit http://creativecommons.org/licenses/by-nc-nd/4.0/
spellingShingle Major Paper
Watanabe, Hidehiro
Takaya, Nobuhiro
Quantitation Error in (1)H MRS Caused by B(1) Inhomogeneity and Chemical Shift Displacement
title Quantitation Error in (1)H MRS Caused by B(1) Inhomogeneity and Chemical Shift Displacement
title_full Quantitation Error in (1)H MRS Caused by B(1) Inhomogeneity and Chemical Shift Displacement
title_fullStr Quantitation Error in (1)H MRS Caused by B(1) Inhomogeneity and Chemical Shift Displacement
title_full_unstemmed Quantitation Error in (1)H MRS Caused by B(1) Inhomogeneity and Chemical Shift Displacement
title_short Quantitation Error in (1)H MRS Caused by B(1) Inhomogeneity and Chemical Shift Displacement
title_sort quantitation error in (1)h mrs caused by b(1) inhomogeneity and chemical shift displacement
topic Major Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6039773/
https://www.ncbi.nlm.nih.gov/pubmed/29118306
http://dx.doi.org/10.2463/mrms.mp.2017-0062
work_keys_str_mv AT watanabehidehiro quantitationerrorin1hmrscausedbyb1inhomogeneityandchemicalshiftdisplacement
AT takayanobuhiro quantitationerrorin1hmrscausedbyb1inhomogeneityandchemicalshiftdisplacement