Cargando…

Single-phase bilateral low dose contrast medium injection for diagnosing occlusions of the thoracic venous system: a case report

Occlusion of the thoracic venous system and/or occlusion of central venous catheters (CVC) of unknown cause can, in selected cases, require advanced imaging. Here, we describe a case study of a patient with a failing central dialysis catheter (CDC) which was diagnosed by computed tomography (CT) in...

Descripción completa

Detalles Bibliográficos
Autores principales: Svensson, Anders, Brismar, Torkel B, Morsbach, Fabian
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6039902/
https://www.ncbi.nlm.nih.gov/pubmed/30013792
http://dx.doi.org/10.1177/2058460118778060
Descripción
Sumario:Occlusion of the thoracic venous system and/or occlusion of central venous catheters (CVC) of unknown cause can, in selected cases, require advanced imaging. Here, we describe a case study of a patient with a failing central dialysis catheter (CDC) which was diagnosed by computed tomography (CT) in connection with a single-phase bilateral low-dose contrast medium (CM) injection using only 3.6 g of iodine. By injecting a low CM dose, the risk of streak artifacts from first-pass of high intravascular concentrations of CM can be avoided. Therefore, the technique described here should be beneficial also to patients with normal renal function.