Measurement of wire deflection on loading may indicate union in Ilizarov constructs, an in vitro model
No entirely reliable method exists for assessing union during Ilizarov treatment. Premature removal results in potential treatment failure; hence, alternative methods warrant investigation. Wire deflection might provide an indication of fracture site deformation on weight bearing, indicating progres...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Milan
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6042221/ https://www.ncbi.nlm.nih.gov/pubmed/29396686 http://dx.doi.org/10.1007/s11751-018-0306-1 |
_version_ | 1783339109708726272 |
---|---|
author | Lineham, Beth Stewart, Todd Harwood, Paul |
author_facet | Lineham, Beth Stewart, Todd Harwood, Paul |
author_sort | Lineham, Beth |
collection | PubMed |
description | No entirely reliable method exists for assessing union during Ilizarov treatment. Premature removal results in potential treatment failure; hence, alternative methods warrant investigation. Wire deflection might provide an indication of fracture site deformation on weight bearing, indicating progress towards union. This study aimed to test a method for assessing wire deflection within an Ilizarov frame. (1) To assess the repeatability of our novel measurement method in measuring wire deflection within an Ilizarov frame in vitro. (2) To compare the amount of wire deflection in an unstable model with that in an intact bone model. (3) To assess accuracy of this method by comparing wire deflection measured with overall machine extension. Tests were performed on clinical grade-tensioned fine wire 4-ring Ilizarov constructs stabilising a simulated fracture, with and without an unstable defect. Models were sequentially loaded to 700 N using an Instron testing machine. A digital depth gauge attached to the superior ring measured relative wire displacement at the ring closest to the fracture. Tests were repeated 3 times. (1) Both unstable and stable bone models produced highly repeatable load deformation curves (R(2) = 0.98 and 0.99). (2) In the unstable model, wires tensioned at 882 and 1274 N produced mean maximum deflections of 2.41 and 2.69 mm compared with 0.05 and 0.04 mm in the intact bone model (significant p < 0.0001). (3) Wire deflection and machine extension results were strongly correlated (r = 0.99). A measurable difference in wire deflection between stable and unstable situations exists using this method which appears accurate and repeatable, with clear correlation between displacement and load and displacement and machine extension. This approach might be clinically applicable, and further clinical testing is required. |
format | Online Article Text |
id | pubmed-6042221 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Springer Milan |
record_format | MEDLINE/PubMed |
spelling | pubmed-60422212018-07-30 Measurement of wire deflection on loading may indicate union in Ilizarov constructs, an in vitro model Lineham, Beth Stewart, Todd Harwood, Paul Strategies Trauma Limb Reconstr Original Article No entirely reliable method exists for assessing union during Ilizarov treatment. Premature removal results in potential treatment failure; hence, alternative methods warrant investigation. Wire deflection might provide an indication of fracture site deformation on weight bearing, indicating progress towards union. This study aimed to test a method for assessing wire deflection within an Ilizarov frame. (1) To assess the repeatability of our novel measurement method in measuring wire deflection within an Ilizarov frame in vitro. (2) To compare the amount of wire deflection in an unstable model with that in an intact bone model. (3) To assess accuracy of this method by comparing wire deflection measured with overall machine extension. Tests were performed on clinical grade-tensioned fine wire 4-ring Ilizarov constructs stabilising a simulated fracture, with and without an unstable defect. Models were sequentially loaded to 700 N using an Instron testing machine. A digital depth gauge attached to the superior ring measured relative wire displacement at the ring closest to the fracture. Tests were repeated 3 times. (1) Both unstable and stable bone models produced highly repeatable load deformation curves (R(2) = 0.98 and 0.99). (2) In the unstable model, wires tensioned at 882 and 1274 N produced mean maximum deflections of 2.41 and 2.69 mm compared with 0.05 and 0.04 mm in the intact bone model (significant p < 0.0001). (3) Wire deflection and machine extension results were strongly correlated (r = 0.99). A measurable difference in wire deflection between stable and unstable situations exists using this method which appears accurate and repeatable, with clear correlation between displacement and load and displacement and machine extension. This approach might be clinically applicable, and further clinical testing is required. Springer Milan 2018-02-02 2018-08 /pmc/articles/PMC6042221/ /pubmed/29396686 http://dx.doi.org/10.1007/s11751-018-0306-1 Text en © The Author(s) 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. |
spellingShingle | Original Article Lineham, Beth Stewart, Todd Harwood, Paul Measurement of wire deflection on loading may indicate union in Ilizarov constructs, an in vitro model |
title | Measurement of wire deflection on loading may indicate union in Ilizarov constructs, an in vitro model |
title_full | Measurement of wire deflection on loading may indicate union in Ilizarov constructs, an in vitro model |
title_fullStr | Measurement of wire deflection on loading may indicate union in Ilizarov constructs, an in vitro model |
title_full_unstemmed | Measurement of wire deflection on loading may indicate union in Ilizarov constructs, an in vitro model |
title_short | Measurement of wire deflection on loading may indicate union in Ilizarov constructs, an in vitro model |
title_sort | measurement of wire deflection on loading may indicate union in ilizarov constructs, an in vitro model |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6042221/ https://www.ncbi.nlm.nih.gov/pubmed/29396686 http://dx.doi.org/10.1007/s11751-018-0306-1 |
work_keys_str_mv | AT linehambeth measurementofwiredeflectiononloadingmayindicateunioninilizarovconstructsaninvitromodel AT stewarttodd measurementofwiredeflectiononloadingmayindicateunioninilizarovconstructsaninvitromodel AT harwoodpaul measurementofwiredeflectiononloadingmayindicateunioninilizarovconstructsaninvitromodel |