Cargando…
The Post Clinic Ambulatory Blood Pressure (PC-ABP) study correlates Post Clinic Blood Pressure (PCBP) with the gold standard Ambulatory Blood Pressure
OBJECTIVE: Our previous study showed that post-clinic blood pressure (BP) taken 15 min after a physician–patient encounter was the lowest reading in a routine clinic. We aimed to validate this reading with 24 h Ambulatory Blood Pressure Monitoring (ABPM) readings. A cross-sectional study was conduct...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6042456/ https://www.ncbi.nlm.nih.gov/pubmed/29996947 http://dx.doi.org/10.1186/s13104-018-3509-0 |
_version_ | 1783339158232629248 |
---|---|
author | Shahab, Hunaina Khan, Hamza Sohail Almas, Aysha Tufail, Mayera Kazmi, Khawar Abbas Khan, Aamir Hameed |
author_facet | Shahab, Hunaina Khan, Hamza Sohail Almas, Aysha Tufail, Mayera Kazmi, Khawar Abbas Khan, Aamir Hameed |
author_sort | Shahab, Hunaina |
collection | PubMed |
description | OBJECTIVE: Our previous study showed that post-clinic blood pressure (BP) taken 15 min after a physician–patient encounter was the lowest reading in a routine clinic. We aimed to validate this reading with 24 h Ambulatory Blood Pressure Monitoring (ABPM) readings. A cross-sectional study was conducted in the cardiology clinics at the Aga Khan University, Pakistan. Hypertensive patients aged ≥ 18 years, or those referred for the diagnosis of hypertension were included. RESULTS: Of 150 participants, 49% were males. 76% of all participants were hypertensive. Pre-clinic BP reading was measured by a nurse, in-clinic by a physician and 15 min post-clinic by a research assistant using a validated, automated BP device (Omron-HEM7221-E). All patients were referred for 24 h ABPM. Among the three readings taken during a clinic visit, mean (± SD) systolic BP (SBP) pre-clinic, in-clinic, and 15 min post-clinic were 153.2 ± 23, 152.3 ± 21, and 140.0 ± 18 mmHg, respectively. Mean (± SD) diastolic BP (DBP) taken pre-clinic, in-clinic and 15 min post-clinic were 83.5 ± 12, 90.9 ± 12, and 86.4 ± 11 mmHg respectively. Mean (± SD) daytime ambulatory SBP, DBP and pulse readings were 134.7 ± 15, 78.7 ± 15 mmHg, and 72.6 ± 12/min, respectively. Pearson correlation coefficients of pre-clinic, in-clinic and post-clinic SBP with daytime ambulatory-SBP were 0.4 (p value: < 0.001), 0.5 (p value: < 0.001) and 0.6 (p value: < 0.001), respectively. Post-clinic BP has a good correlation with ambulatory BP and may be considered a more reliable reading in the clinic setting. |
format | Online Article Text |
id | pubmed-6042456 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-60424562018-07-13 The Post Clinic Ambulatory Blood Pressure (PC-ABP) study correlates Post Clinic Blood Pressure (PCBP) with the gold standard Ambulatory Blood Pressure Shahab, Hunaina Khan, Hamza Sohail Almas, Aysha Tufail, Mayera Kazmi, Khawar Abbas Khan, Aamir Hameed BMC Res Notes Research Note OBJECTIVE: Our previous study showed that post-clinic blood pressure (BP) taken 15 min after a physician–patient encounter was the lowest reading in a routine clinic. We aimed to validate this reading with 24 h Ambulatory Blood Pressure Monitoring (ABPM) readings. A cross-sectional study was conducted in the cardiology clinics at the Aga Khan University, Pakistan. Hypertensive patients aged ≥ 18 years, or those referred for the diagnosis of hypertension were included. RESULTS: Of 150 participants, 49% were males. 76% of all participants were hypertensive. Pre-clinic BP reading was measured by a nurse, in-clinic by a physician and 15 min post-clinic by a research assistant using a validated, automated BP device (Omron-HEM7221-E). All patients were referred for 24 h ABPM. Among the three readings taken during a clinic visit, mean (± SD) systolic BP (SBP) pre-clinic, in-clinic, and 15 min post-clinic were 153.2 ± 23, 152.3 ± 21, and 140.0 ± 18 mmHg, respectively. Mean (± SD) diastolic BP (DBP) taken pre-clinic, in-clinic and 15 min post-clinic were 83.5 ± 12, 90.9 ± 12, and 86.4 ± 11 mmHg respectively. Mean (± SD) daytime ambulatory SBP, DBP and pulse readings were 134.7 ± 15, 78.7 ± 15 mmHg, and 72.6 ± 12/min, respectively. Pearson correlation coefficients of pre-clinic, in-clinic and post-clinic SBP with daytime ambulatory-SBP were 0.4 (p value: < 0.001), 0.5 (p value: < 0.001) and 0.6 (p value: < 0.001), respectively. Post-clinic BP has a good correlation with ambulatory BP and may be considered a more reliable reading in the clinic setting. BioMed Central 2018-07-11 /pmc/articles/PMC6042456/ /pubmed/29996947 http://dx.doi.org/10.1186/s13104-018-3509-0 Text en © The Author(s) 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Note Shahab, Hunaina Khan, Hamza Sohail Almas, Aysha Tufail, Mayera Kazmi, Khawar Abbas Khan, Aamir Hameed The Post Clinic Ambulatory Blood Pressure (PC-ABP) study correlates Post Clinic Blood Pressure (PCBP) with the gold standard Ambulatory Blood Pressure |
title | The Post Clinic Ambulatory Blood Pressure (PC-ABP) study correlates Post Clinic Blood Pressure (PCBP) with the gold standard Ambulatory Blood Pressure |
title_full | The Post Clinic Ambulatory Blood Pressure (PC-ABP) study correlates Post Clinic Blood Pressure (PCBP) with the gold standard Ambulatory Blood Pressure |
title_fullStr | The Post Clinic Ambulatory Blood Pressure (PC-ABP) study correlates Post Clinic Blood Pressure (PCBP) with the gold standard Ambulatory Blood Pressure |
title_full_unstemmed | The Post Clinic Ambulatory Blood Pressure (PC-ABP) study correlates Post Clinic Blood Pressure (PCBP) with the gold standard Ambulatory Blood Pressure |
title_short | The Post Clinic Ambulatory Blood Pressure (PC-ABP) study correlates Post Clinic Blood Pressure (PCBP) with the gold standard Ambulatory Blood Pressure |
title_sort | post clinic ambulatory blood pressure (pc-abp) study correlates post clinic blood pressure (pcbp) with the gold standard ambulatory blood pressure |
topic | Research Note |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6042456/ https://www.ncbi.nlm.nih.gov/pubmed/29996947 http://dx.doi.org/10.1186/s13104-018-3509-0 |
work_keys_str_mv | AT shahabhunaina thepostclinicambulatorybloodpressurepcabpstudycorrelatespostclinicbloodpressurepcbpwiththegoldstandardambulatorybloodpressure AT khanhamzasohail thepostclinicambulatorybloodpressurepcabpstudycorrelatespostclinicbloodpressurepcbpwiththegoldstandardambulatorybloodpressure AT almasaysha thepostclinicambulatorybloodpressurepcabpstudycorrelatespostclinicbloodpressurepcbpwiththegoldstandardambulatorybloodpressure AT tufailmayera thepostclinicambulatorybloodpressurepcabpstudycorrelatespostclinicbloodpressurepcbpwiththegoldstandardambulatorybloodpressure AT kazmikhawarabbas thepostclinicambulatorybloodpressurepcabpstudycorrelatespostclinicbloodpressurepcbpwiththegoldstandardambulatorybloodpressure AT khanaamirhameed thepostclinicambulatorybloodpressurepcabpstudycorrelatespostclinicbloodpressurepcbpwiththegoldstandardambulatorybloodpressure AT shahabhunaina postclinicambulatorybloodpressurepcabpstudycorrelatespostclinicbloodpressurepcbpwiththegoldstandardambulatorybloodpressure AT khanhamzasohail postclinicambulatorybloodpressurepcabpstudycorrelatespostclinicbloodpressurepcbpwiththegoldstandardambulatorybloodpressure AT almasaysha postclinicambulatorybloodpressurepcabpstudycorrelatespostclinicbloodpressurepcbpwiththegoldstandardambulatorybloodpressure AT tufailmayera postclinicambulatorybloodpressurepcabpstudycorrelatespostclinicbloodpressurepcbpwiththegoldstandardambulatorybloodpressure AT kazmikhawarabbas postclinicambulatorybloodpressurepcabpstudycorrelatespostclinicbloodpressurepcbpwiththegoldstandardambulatorybloodpressure AT khanaamirhameed postclinicambulatorybloodpressurepcabpstudycorrelatespostclinicbloodpressurepcbpwiththegoldstandardambulatorybloodpressure |