Cargando…

Comparison of body composition assessment by DXA and BIA according to the body mass index: A retrospective study on 3655 measures

BACKGROUND AND AIMS: Body composition assessment is often used in clinical practice for nutritional evaluation and monitoring. The standard method, dual-energy X-ray absorptiometry (DXA), is hardly feasible in routine clinical practice contrary to Bioelectrical Impedance Analysis (BIA) method. We th...

Descripción completa

Detalles Bibliográficos
Autores principales: Achamrah, Najate, Colange, Guillaume, Delay, Julie, Rimbert, Agnès, Folope, Vanessa, Petit, André, Grigioni, Sébastien, Déchelotte, Pierre, Coëffier, Moïse
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6042744/
https://www.ncbi.nlm.nih.gov/pubmed/30001381
http://dx.doi.org/10.1371/journal.pone.0200465
_version_ 1783339210207395840
author Achamrah, Najate
Colange, Guillaume
Delay, Julie
Rimbert, Agnès
Folope, Vanessa
Petit, André
Grigioni, Sébastien
Déchelotte, Pierre
Coëffier, Moïse
author_facet Achamrah, Najate
Colange, Guillaume
Delay, Julie
Rimbert, Agnès
Folope, Vanessa
Petit, André
Grigioni, Sébastien
Déchelotte, Pierre
Coëffier, Moïse
author_sort Achamrah, Najate
collection PubMed
description BACKGROUND AND AIMS: Body composition assessment is often used in clinical practice for nutritional evaluation and monitoring. The standard method, dual-energy X-ray absorptiometry (DXA), is hardly feasible in routine clinical practice contrary to Bioelectrical Impedance Analysis (BIA) method. We thus aimed to compare body composition assessment by DXA and BIA according to the body mass index (BMI) in a large cohort. METHODS: Retrospectively, we analysed DXA and BIA measures in patients followed in a Nutrition Unit from 2010 to 2016. Body composition was assessed under standardized conditions in the morning, after a fasting period of 12 h, by DXA (Lunar Prodigy Advance) and BIA (Bodystat QuadScan 4000, Manufacturer’s equation). Bland-Altman test was performed for each class of BMI (kg/m(2)) and fat mass and fat free mass values were compared using Kruskal-Wallis test. Pearson correlations were also performed and the concordance coefficient of Lin was calculated. RESULTS: Whatever the BMI, BIA and DXA methods reported higher concordance for values of FM than FFM. Body composition values were very closed for patients with BMI between 16 and 18,5 (difference < 1kg). For BMI > 18,5 and BMI < 40, BIA overestimated fat free mass from 3,38 to 8,28 kg, and underestimated fat mass from 2,51 to 5,67 kg compared with DXA method. For BMI ≥ 40, differences vary with BMI. For BMI < 16, BIA underestimated fat free mass by 2,25 kg, and overestimated fat mass by 2,57 kg. However, limits of agreement were very large either for FM and FFM values, irrespective of BMI. CONCLUSION: The small bias, particularly in patients with BMI between 16 and 18, suggests that BIA and DXA methods are interchangeable at a population level. However, concordance between BIA and DXA methods at the individual level is lacking, irrespective of BMI.
format Online
Article
Text
id pubmed-6042744
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-60427442018-07-19 Comparison of body composition assessment by DXA and BIA according to the body mass index: A retrospective study on 3655 measures Achamrah, Najate Colange, Guillaume Delay, Julie Rimbert, Agnès Folope, Vanessa Petit, André Grigioni, Sébastien Déchelotte, Pierre Coëffier, Moïse PLoS One Research Article BACKGROUND AND AIMS: Body composition assessment is often used in clinical practice for nutritional evaluation and monitoring. The standard method, dual-energy X-ray absorptiometry (DXA), is hardly feasible in routine clinical practice contrary to Bioelectrical Impedance Analysis (BIA) method. We thus aimed to compare body composition assessment by DXA and BIA according to the body mass index (BMI) in a large cohort. METHODS: Retrospectively, we analysed DXA and BIA measures in patients followed in a Nutrition Unit from 2010 to 2016. Body composition was assessed under standardized conditions in the morning, after a fasting period of 12 h, by DXA (Lunar Prodigy Advance) and BIA (Bodystat QuadScan 4000, Manufacturer’s equation). Bland-Altman test was performed for each class of BMI (kg/m(2)) and fat mass and fat free mass values were compared using Kruskal-Wallis test. Pearson correlations were also performed and the concordance coefficient of Lin was calculated. RESULTS: Whatever the BMI, BIA and DXA methods reported higher concordance for values of FM than FFM. Body composition values were very closed for patients with BMI between 16 and 18,5 (difference < 1kg). For BMI > 18,5 and BMI < 40, BIA overestimated fat free mass from 3,38 to 8,28 kg, and underestimated fat mass from 2,51 to 5,67 kg compared with DXA method. For BMI ≥ 40, differences vary with BMI. For BMI < 16, BIA underestimated fat free mass by 2,25 kg, and overestimated fat mass by 2,57 kg. However, limits of agreement were very large either for FM and FFM values, irrespective of BMI. CONCLUSION: The small bias, particularly in patients with BMI between 16 and 18, suggests that BIA and DXA methods are interchangeable at a population level. However, concordance between BIA and DXA methods at the individual level is lacking, irrespective of BMI. Public Library of Science 2018-07-12 /pmc/articles/PMC6042744/ /pubmed/30001381 http://dx.doi.org/10.1371/journal.pone.0200465 Text en © 2018 Achamrah et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Achamrah, Najate
Colange, Guillaume
Delay, Julie
Rimbert, Agnès
Folope, Vanessa
Petit, André
Grigioni, Sébastien
Déchelotte, Pierre
Coëffier, Moïse
Comparison of body composition assessment by DXA and BIA according to the body mass index: A retrospective study on 3655 measures
title Comparison of body composition assessment by DXA and BIA according to the body mass index: A retrospective study on 3655 measures
title_full Comparison of body composition assessment by DXA and BIA according to the body mass index: A retrospective study on 3655 measures
title_fullStr Comparison of body composition assessment by DXA and BIA according to the body mass index: A retrospective study on 3655 measures
title_full_unstemmed Comparison of body composition assessment by DXA and BIA according to the body mass index: A retrospective study on 3655 measures
title_short Comparison of body composition assessment by DXA and BIA according to the body mass index: A retrospective study on 3655 measures
title_sort comparison of body composition assessment by dxa and bia according to the body mass index: a retrospective study on 3655 measures
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6042744/
https://www.ncbi.nlm.nih.gov/pubmed/30001381
http://dx.doi.org/10.1371/journal.pone.0200465
work_keys_str_mv AT achamrahnajate comparisonofbodycompositionassessmentbydxaandbiaaccordingtothebodymassindexaretrospectivestudyon3655measures
AT colangeguillaume comparisonofbodycompositionassessmentbydxaandbiaaccordingtothebodymassindexaretrospectivestudyon3655measures
AT delayjulie comparisonofbodycompositionassessmentbydxaandbiaaccordingtothebodymassindexaretrospectivestudyon3655measures
AT rimbertagnes comparisonofbodycompositionassessmentbydxaandbiaaccordingtothebodymassindexaretrospectivestudyon3655measures
AT folopevanessa comparisonofbodycompositionassessmentbydxaandbiaaccordingtothebodymassindexaretrospectivestudyon3655measures
AT petitandre comparisonofbodycompositionassessmentbydxaandbiaaccordingtothebodymassindexaretrospectivestudyon3655measures
AT grigionisebastien comparisonofbodycompositionassessmentbydxaandbiaaccordingtothebodymassindexaretrospectivestudyon3655measures
AT dechelottepierre comparisonofbodycompositionassessmentbydxaandbiaaccordingtothebodymassindexaretrospectivestudyon3655measures
AT coeffiermoise comparisonofbodycompositionassessmentbydxaandbiaaccordingtothebodymassindexaretrospectivestudyon3655measures