Cargando…

Diagnostic accuracy of loop-mediated isothermal amplification (LAMP) for screening malaria in peripheral and placental blood samples from pregnant women in Colombia

BACKGROUND: Pregnant women frequently show low-density Plasmodium infections that require more sensitive methods for accurate diagnosis and early treatment of malaria. This is particularly relevant in low-malaria transmission areas, where intermittent preventive treatment is not recommended. Molecul...

Descripción completa

Detalles Bibliográficos
Autores principales: Vásquez, Ana María, Zuluaga, Lina, Tobón, Alberto, Posada, Maritza, Vélez, Gabriel, González, Iveth J., Campillo, Ana, Ding, Xavier
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6044080/
https://www.ncbi.nlm.nih.gov/pubmed/30005616
http://dx.doi.org/10.1186/s12936-018-2403-5
_version_ 1783339410322882560
author Vásquez, Ana María
Zuluaga, Lina
Tobón, Alberto
Posada, Maritza
Vélez, Gabriel
González, Iveth J.
Campillo, Ana
Ding, Xavier
author_facet Vásquez, Ana María
Zuluaga, Lina
Tobón, Alberto
Posada, Maritza
Vélez, Gabriel
González, Iveth J.
Campillo, Ana
Ding, Xavier
author_sort Vásquez, Ana María
collection PubMed
description BACKGROUND: Pregnant women frequently show low-density Plasmodium infections that require more sensitive methods for accurate diagnosis and early treatment of malaria. This is particularly relevant in low-malaria transmission areas, where intermittent preventive treatment is not recommended. Molecular methods, such as polymerase chain reaction (PCR) are highly sensitive, but require sophisticated equipment and advanced training. Instead, loop mediated isothermal amplification (LAMP) provides an opportunity for molecular detection of malaria infections in remote endemic areas, outside a reference laboratory. The aim of the study is to evaluate the performance of LAMP for the screening of malaria in pregnant women in Colombia. METHODS: This is a nested prospective study that uses data and samples from a larger cross-sectional project conducted from May 2016 to January 2017 in three Colombian endemic areas (El Bagre, Quibdó, and Tumaco). A total of 531 peripheral and placental samples from pregnant women self-presenting at local hospitals for antenatal care visits, at delivery or seeking medical care for suspected malaria were collected. Samples were analysed for Plasmodium parasites by light microscopy (LM), rapid diagnostic test (RDT) and LAMP. Diagnostic accuracy endpoints (sensitivity, specificity, predictive values, and kappa scores) of LM, RDT and LAMP were compared with nested PCR (nPCR) as the reference standard. RESULTS: In peripheral samples, LAMP showed an improved sensitivity (100.0%) when compared with LM 79.5% and RDT 76.9% (p < 0.01), particularly in afebrile women, for which LAMP sensitivity was two-times higher than LM and RDT. Overall agreement among LAMP and nPCR was high (kappa value = 1.0). Specificity was similar in all tests (100%). In placental blood, LAMP evidenced a four-fold improvement in sensitivity (88.9%) when compared with LM and RDT (22.2%), being the only method, together with nPCR, able to detect placental infections in peripheral blood. CONCLUSIONS: LAMP is a simple, rapid and accurate molecular tool for detecting gestational and placental malaria, being able to overcome the limited sensitivity of LM and RDT. These findings could guide maternal health programs in low-transmission settings to integrate LAMP in their surveillance systems for the active detection of low-density infections and asymptomatic malaria cases.
format Online
Article
Text
id pubmed-6044080
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-60440802018-07-16 Diagnostic accuracy of loop-mediated isothermal amplification (LAMP) for screening malaria in peripheral and placental blood samples from pregnant women in Colombia Vásquez, Ana María Zuluaga, Lina Tobón, Alberto Posada, Maritza Vélez, Gabriel González, Iveth J. Campillo, Ana Ding, Xavier Malar J Research BACKGROUND: Pregnant women frequently show low-density Plasmodium infections that require more sensitive methods for accurate diagnosis and early treatment of malaria. This is particularly relevant in low-malaria transmission areas, where intermittent preventive treatment is not recommended. Molecular methods, such as polymerase chain reaction (PCR) are highly sensitive, but require sophisticated equipment and advanced training. Instead, loop mediated isothermal amplification (LAMP) provides an opportunity for molecular detection of malaria infections in remote endemic areas, outside a reference laboratory. The aim of the study is to evaluate the performance of LAMP for the screening of malaria in pregnant women in Colombia. METHODS: This is a nested prospective study that uses data and samples from a larger cross-sectional project conducted from May 2016 to January 2017 in three Colombian endemic areas (El Bagre, Quibdó, and Tumaco). A total of 531 peripheral and placental samples from pregnant women self-presenting at local hospitals for antenatal care visits, at delivery or seeking medical care for suspected malaria were collected. Samples were analysed for Plasmodium parasites by light microscopy (LM), rapid diagnostic test (RDT) and LAMP. Diagnostic accuracy endpoints (sensitivity, specificity, predictive values, and kappa scores) of LM, RDT and LAMP were compared with nested PCR (nPCR) as the reference standard. RESULTS: In peripheral samples, LAMP showed an improved sensitivity (100.0%) when compared with LM 79.5% and RDT 76.9% (p < 0.01), particularly in afebrile women, for which LAMP sensitivity was two-times higher than LM and RDT. Overall agreement among LAMP and nPCR was high (kappa value = 1.0). Specificity was similar in all tests (100%). In placental blood, LAMP evidenced a four-fold improvement in sensitivity (88.9%) when compared with LM and RDT (22.2%), being the only method, together with nPCR, able to detect placental infections in peripheral blood. CONCLUSIONS: LAMP is a simple, rapid and accurate molecular tool for detecting gestational and placental malaria, being able to overcome the limited sensitivity of LM and RDT. These findings could guide maternal health programs in low-transmission settings to integrate LAMP in their surveillance systems for the active detection of low-density infections and asymptomatic malaria cases. BioMed Central 2018-07-13 /pmc/articles/PMC6044080/ /pubmed/30005616 http://dx.doi.org/10.1186/s12936-018-2403-5 Text en © The Author(s) 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Vásquez, Ana María
Zuluaga, Lina
Tobón, Alberto
Posada, Maritza
Vélez, Gabriel
González, Iveth J.
Campillo, Ana
Ding, Xavier
Diagnostic accuracy of loop-mediated isothermal amplification (LAMP) for screening malaria in peripheral and placental blood samples from pregnant women in Colombia
title Diagnostic accuracy of loop-mediated isothermal amplification (LAMP) for screening malaria in peripheral and placental blood samples from pregnant women in Colombia
title_full Diagnostic accuracy of loop-mediated isothermal amplification (LAMP) for screening malaria in peripheral and placental blood samples from pregnant women in Colombia
title_fullStr Diagnostic accuracy of loop-mediated isothermal amplification (LAMP) for screening malaria in peripheral and placental blood samples from pregnant women in Colombia
title_full_unstemmed Diagnostic accuracy of loop-mediated isothermal amplification (LAMP) for screening malaria in peripheral and placental blood samples from pregnant women in Colombia
title_short Diagnostic accuracy of loop-mediated isothermal amplification (LAMP) for screening malaria in peripheral and placental blood samples from pregnant women in Colombia
title_sort diagnostic accuracy of loop-mediated isothermal amplification (lamp) for screening malaria in peripheral and placental blood samples from pregnant women in colombia
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6044080/
https://www.ncbi.nlm.nih.gov/pubmed/30005616
http://dx.doi.org/10.1186/s12936-018-2403-5
work_keys_str_mv AT vasquezanamaria diagnosticaccuracyofloopmediatedisothermalamplificationlampforscreeningmalariainperipheralandplacentalbloodsamplesfrompregnantwomenincolombia
AT zuluagalina diagnosticaccuracyofloopmediatedisothermalamplificationlampforscreeningmalariainperipheralandplacentalbloodsamplesfrompregnantwomenincolombia
AT tobonalberto diagnosticaccuracyofloopmediatedisothermalamplificationlampforscreeningmalariainperipheralandplacentalbloodsamplesfrompregnantwomenincolombia
AT posadamaritza diagnosticaccuracyofloopmediatedisothermalamplificationlampforscreeningmalariainperipheralandplacentalbloodsamplesfrompregnantwomenincolombia
AT velezgabriel diagnosticaccuracyofloopmediatedisothermalamplificationlampforscreeningmalariainperipheralandplacentalbloodsamplesfrompregnantwomenincolombia
AT gonzalezivethj diagnosticaccuracyofloopmediatedisothermalamplificationlampforscreeningmalariainperipheralandplacentalbloodsamplesfrompregnantwomenincolombia
AT campilloana diagnosticaccuracyofloopmediatedisothermalamplificationlampforscreeningmalariainperipheralandplacentalbloodsamplesfrompregnantwomenincolombia
AT dingxavier diagnosticaccuracyofloopmediatedisothermalamplificationlampforscreeningmalariainperipheralandplacentalbloodsamplesfrompregnantwomenincolombia