Cargando…

Influence of the moving fluoroscope on gait patterns

Video-fluoroscopic analysis can provide important insights for the evaluation of outcome and functionality after total knee arthroplasty, allowing the in vivo assessment of tibiofemoral kinematics without soft tissue artefacts. To enable measurement of the knee throughout activities of daily living...

Descripción completa

Detalles Bibliográficos
Autores principales: Hitz, Marina, Schütz, Pascal, Angst, Michael, Taylor, William R., List, Renate
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6044540/
https://www.ncbi.nlm.nih.gov/pubmed/30005086
http://dx.doi.org/10.1371/journal.pone.0200608
_version_ 1783339491669311488
author Hitz, Marina
Schütz, Pascal
Angst, Michael
Taylor, William R.
List, Renate
author_facet Hitz, Marina
Schütz, Pascal
Angst, Michael
Taylor, William R.
List, Renate
author_sort Hitz, Marina
collection PubMed
description Video-fluoroscopic analysis can provide important insights for the evaluation of outcome and functionality after total knee arthroplasty, allowing the in vivo assessment of tibiofemoral kinematics without soft tissue artefacts. To enable measurement of the knee throughout activities of daily living such as gait, robotic systems like the moving fluoroscope have been developed that follow the knee movement and maintain the joint in front of the image intensifier. Since it is unclear whether walking while being accompanied by moving fluoroscope affects normal gait, the objective of this study was to investigate its influence on gait characteristics in healthy subjects. In addition, the impact of the motors’ noise was analysed. By means of skin markers analysis (VICON MX system, Oxford Metrics Group, UK) and simultaneous measurement of ground reaction forces (Kistler force plates, Kistler, Switzerland), gait characteristics when walking with and without the moving fluoroscope as well as with and without ear protectors in combination with the moving fluoroscope, were obtained in young (n = 10, 24.5y ± 3.0y) and elderly (n = 9, 61.6y ± 5.3y) subjects during level gait and stair descent. Walking with the moving fluoroscope significantly decreased gait velocity in level gait and stair descent over the respective movement without the fluoroscope. Statistical analysis, including gait velocity as a covariate, resulted in no differences on the ground reaction force parameters. However, some kinematic parameters (ankle, knee and hip ranges of motion, minimal knee angle in late stance phase, maximal knee angles in stance and swing phase) seemed to be modified by the presence of the moving fluoroscope, but statistical comparison was limited due to velocity differences between the conditions. Wearing ear protectors to avoid the influence of motor sound during walking with the moving fluoroscope caused no significant difference. Walking with the moving fluoroscope has been shown to decrease gait velocity and small alterations in kinematic parameters were observed. Therefore, gait and movement alterations due to the moving fluoroscope cannot completely be excluded. However, based on the absence of differences in ground reaction force parameters (when adjusted for velocity within ANCOVA), as well as based on the comparable shape of the angular curves to the slow control condition, it can be concluded that changes in gait when walking with the moving fluoroscope are small, especially in comparison to natural slow walking. In order to allow assessment of joint replacement with the moving fluoroscope, including an understanding of the effects of joint pain, clinical analyses can only be compared to gait activities showing similarly reduced velocities. Importantly, the reduced gait speeds observed in this study are similar to those observed after total knee arthroplasty, suggesting that analyses in such subjects are appropriate. However, the moving fluoroscope would likely need to be optimized in order to detect natural gait characteristics at the higher gait velocities of healthy young subjects. The moving fluoroscope can be applied for comparisons between groups measured with the moving fluoroscope, but care should be taken when comparing data to subjects walking at self-selected speed without the moving fluoroscope.
format Online
Article
Text
id pubmed-6044540
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-60445402018-07-26 Influence of the moving fluoroscope on gait patterns Hitz, Marina Schütz, Pascal Angst, Michael Taylor, William R. List, Renate PLoS One Research Article Video-fluoroscopic analysis can provide important insights for the evaluation of outcome and functionality after total knee arthroplasty, allowing the in vivo assessment of tibiofemoral kinematics without soft tissue artefacts. To enable measurement of the knee throughout activities of daily living such as gait, robotic systems like the moving fluoroscope have been developed that follow the knee movement and maintain the joint in front of the image intensifier. Since it is unclear whether walking while being accompanied by moving fluoroscope affects normal gait, the objective of this study was to investigate its influence on gait characteristics in healthy subjects. In addition, the impact of the motors’ noise was analysed. By means of skin markers analysis (VICON MX system, Oxford Metrics Group, UK) and simultaneous measurement of ground reaction forces (Kistler force plates, Kistler, Switzerland), gait characteristics when walking with and without the moving fluoroscope as well as with and without ear protectors in combination with the moving fluoroscope, were obtained in young (n = 10, 24.5y ± 3.0y) and elderly (n = 9, 61.6y ± 5.3y) subjects during level gait and stair descent. Walking with the moving fluoroscope significantly decreased gait velocity in level gait and stair descent over the respective movement without the fluoroscope. Statistical analysis, including gait velocity as a covariate, resulted in no differences on the ground reaction force parameters. However, some kinematic parameters (ankle, knee and hip ranges of motion, minimal knee angle in late stance phase, maximal knee angles in stance and swing phase) seemed to be modified by the presence of the moving fluoroscope, but statistical comparison was limited due to velocity differences between the conditions. Wearing ear protectors to avoid the influence of motor sound during walking with the moving fluoroscope caused no significant difference. Walking with the moving fluoroscope has been shown to decrease gait velocity and small alterations in kinematic parameters were observed. Therefore, gait and movement alterations due to the moving fluoroscope cannot completely be excluded. However, based on the absence of differences in ground reaction force parameters (when adjusted for velocity within ANCOVA), as well as based on the comparable shape of the angular curves to the slow control condition, it can be concluded that changes in gait when walking with the moving fluoroscope are small, especially in comparison to natural slow walking. In order to allow assessment of joint replacement with the moving fluoroscope, including an understanding of the effects of joint pain, clinical analyses can only be compared to gait activities showing similarly reduced velocities. Importantly, the reduced gait speeds observed in this study are similar to those observed after total knee arthroplasty, suggesting that analyses in such subjects are appropriate. However, the moving fluoroscope would likely need to be optimized in order to detect natural gait characteristics at the higher gait velocities of healthy young subjects. The moving fluoroscope can be applied for comparisons between groups measured with the moving fluoroscope, but care should be taken when comparing data to subjects walking at self-selected speed without the moving fluoroscope. Public Library of Science 2018-07-13 /pmc/articles/PMC6044540/ /pubmed/30005086 http://dx.doi.org/10.1371/journal.pone.0200608 Text en © 2018 Hitz et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Hitz, Marina
Schütz, Pascal
Angst, Michael
Taylor, William R.
List, Renate
Influence of the moving fluoroscope on gait patterns
title Influence of the moving fluoroscope on gait patterns
title_full Influence of the moving fluoroscope on gait patterns
title_fullStr Influence of the moving fluoroscope on gait patterns
title_full_unstemmed Influence of the moving fluoroscope on gait patterns
title_short Influence of the moving fluoroscope on gait patterns
title_sort influence of the moving fluoroscope on gait patterns
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6044540/
https://www.ncbi.nlm.nih.gov/pubmed/30005086
http://dx.doi.org/10.1371/journal.pone.0200608
work_keys_str_mv AT hitzmarina influenceofthemovingfluoroscopeongaitpatterns
AT schutzpascal influenceofthemovingfluoroscopeongaitpatterns
AT angstmichael influenceofthemovingfluoroscopeongaitpatterns
AT taylorwilliamr influenceofthemovingfluoroscopeongaitpatterns
AT listrenate influenceofthemovingfluoroscopeongaitpatterns