Safe Margin beyond Dens Tips to Ventral Dura in Anterior Odontoid Screw Fixation : Analysis of Three-Dimensional Computed Tomography Scan of Odontoid Process

OBJECTIVE: Anterior odontoid screw fixation is a safe and effective method for the treatment of odontoid fractures. The surgical technique is recommended for perforation of the apical cortex of the dens by the lag screw. However, overpenetration of the apical cortex may lead to potentially serious c...

Descripción completa

Detalles Bibliográficos
Autores principales: Sung, Min-Jae, Kim, Kyoung-Tae, Hwang, Jeong-Hyun, Sung, Joo-Kyung, Cho, Dae-Chul
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Neurosurgical Society 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6046568/
https://www.ncbi.nlm.nih.gov/pubmed/29991109
http://dx.doi.org/10.3340/jkns.2018.0034
_version_ 1783339839434784768
author Sung, Min-Jae
Kim, Kyoung-Tae
Hwang, Jeong-Hyun
Sung, Joo-Kyung
Cho, Dae-Chul
author_facet Sung, Min-Jae
Kim, Kyoung-Tae
Hwang, Jeong-Hyun
Sung, Joo-Kyung
Cho, Dae-Chul
author_sort Sung, Min-Jae
collection PubMed
description OBJECTIVE: Anterior odontoid screw fixation is a safe and effective method for the treatment of odontoid fractures. The surgical technique is recommended for perforation of the apical cortex of the dens by the lag screw. However, overpenetration of the apical cortex may lead to potentially serious complications such as damages of adjacent vascular and neural structures. The purpose of this study was to assess the role of three-dimensional computed tomography (CT) scan to evaluate the safe margin beyond dens tip to ventral dura for anterior odontoid screw fixation. METHODS: We retrospectively analyzed the three-dimensional CT scans of the cervical spines in 55 consecutive patients at our trauma center. The patients included 38 males and 17 females aged between 22 and 73 years (mean age±standard deviation, 45.8±14.2 years). Using sagittal images of 3-dimensional CT scan, the safe margins beyond dens tip to ventral dura as well as the appropriate screw length were measured. RESULTS: The mean width of the apical dens tip was 9.6±1.1 mm. The mean lengths from the screw entry point to the apical dens tip and posterior end of dens tip were 39.2±2.6 mm and 36.6±2.4 mm. The safe margin beyond apical dens tip to ventral dura was 7.7±1.7 mm. However, the safe margin beyond the posterior end of dens tip to ventral dura was decreased to 2.1±3.2 mm, which was statistically significant (p<0.01). There were no significant differences of safe margins beyond dens tip to ventral dura with patient gender and age. CONCLUSION: Extension by several millimeters beyond the dens tip is safe, if the trajectory of anterior odontoid screw is targeted at the apical dens tip. However, if the trajectory of the screw is targeted to the posterior end of dens tip, extension beyond dens tip may lead to damage immediately adjacent to the vental dura mater.
format Online
Article
Text
id pubmed-6046568
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Korean Neurosurgical Society
record_format MEDLINE/PubMed
spelling pubmed-60465682018-07-16 Safe Margin beyond Dens Tips to Ventral Dura in Anterior Odontoid Screw Fixation : Analysis of Three-Dimensional Computed Tomography Scan of Odontoid Process Sung, Min-Jae Kim, Kyoung-Tae Hwang, Jeong-Hyun Sung, Joo-Kyung Cho, Dae-Chul J Korean Neurosurg Soc Clinical Article OBJECTIVE: Anterior odontoid screw fixation is a safe and effective method for the treatment of odontoid fractures. The surgical technique is recommended for perforation of the apical cortex of the dens by the lag screw. However, overpenetration of the apical cortex may lead to potentially serious complications such as damages of adjacent vascular and neural structures. The purpose of this study was to assess the role of three-dimensional computed tomography (CT) scan to evaluate the safe margin beyond dens tip to ventral dura for anterior odontoid screw fixation. METHODS: We retrospectively analyzed the three-dimensional CT scans of the cervical spines in 55 consecutive patients at our trauma center. The patients included 38 males and 17 females aged between 22 and 73 years (mean age±standard deviation, 45.8±14.2 years). Using sagittal images of 3-dimensional CT scan, the safe margins beyond dens tip to ventral dura as well as the appropriate screw length were measured. RESULTS: The mean width of the apical dens tip was 9.6±1.1 mm. The mean lengths from the screw entry point to the apical dens tip and posterior end of dens tip were 39.2±2.6 mm and 36.6±2.4 mm. The safe margin beyond apical dens tip to ventral dura was 7.7±1.7 mm. However, the safe margin beyond the posterior end of dens tip to ventral dura was decreased to 2.1±3.2 mm, which was statistically significant (p<0.01). There were no significant differences of safe margins beyond dens tip to ventral dura with patient gender and age. CONCLUSION: Extension by several millimeters beyond the dens tip is safe, if the trajectory of anterior odontoid screw is targeted at the apical dens tip. However, if the trajectory of the screw is targeted to the posterior end of dens tip, extension beyond dens tip may lead to damage immediately adjacent to the vental dura mater. Korean Neurosurgical Society 2018-07 2018-07-01 /pmc/articles/PMC6046568/ /pubmed/29991109 http://dx.doi.org/10.3340/jkns.2018.0034 Text en Copyright © 2018 Korean Neurosurgical Society This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Clinical Article
Sung, Min-Jae
Kim, Kyoung-Tae
Hwang, Jeong-Hyun
Sung, Joo-Kyung
Cho, Dae-Chul
Safe Margin beyond Dens Tips to Ventral Dura in Anterior Odontoid Screw Fixation : Analysis of Three-Dimensional Computed Tomography Scan of Odontoid Process
title Safe Margin beyond Dens Tips to Ventral Dura in Anterior Odontoid Screw Fixation : Analysis of Three-Dimensional Computed Tomography Scan of Odontoid Process
title_full Safe Margin beyond Dens Tips to Ventral Dura in Anterior Odontoid Screw Fixation : Analysis of Three-Dimensional Computed Tomography Scan of Odontoid Process
title_fullStr Safe Margin beyond Dens Tips to Ventral Dura in Anterior Odontoid Screw Fixation : Analysis of Three-Dimensional Computed Tomography Scan of Odontoid Process
title_full_unstemmed Safe Margin beyond Dens Tips to Ventral Dura in Anterior Odontoid Screw Fixation : Analysis of Three-Dimensional Computed Tomography Scan of Odontoid Process
title_short Safe Margin beyond Dens Tips to Ventral Dura in Anterior Odontoid Screw Fixation : Analysis of Three-Dimensional Computed Tomography Scan of Odontoid Process
title_sort safe margin beyond dens tips to ventral dura in anterior odontoid screw fixation : analysis of three-dimensional computed tomography scan of odontoid process
topic Clinical Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6046568/
https://www.ncbi.nlm.nih.gov/pubmed/29991109
http://dx.doi.org/10.3340/jkns.2018.0034
work_keys_str_mv AT sungminjae safemarginbeyonddenstipstoventraldurainanteriorodontoidscrewfixationanalysisofthreedimensionalcomputedtomographyscanofodontoidprocess
AT kimkyoungtae safemarginbeyonddenstipstoventraldurainanteriorodontoidscrewfixationanalysisofthreedimensionalcomputedtomographyscanofodontoidprocess
AT hwangjeonghyun safemarginbeyonddenstipstoventraldurainanteriorodontoidscrewfixationanalysisofthreedimensionalcomputedtomographyscanofodontoidprocess
AT sungjookyung safemarginbeyonddenstipstoventraldurainanteriorodontoidscrewfixationanalysisofthreedimensionalcomputedtomographyscanofodontoidprocess
AT chodaechul safemarginbeyonddenstipstoventraldurainanteriorodontoidscrewfixationanalysisofthreedimensionalcomputedtomographyscanofodontoidprocess