Cargando…

A standardized protocol for quantification of saccadic eye movements: DEMoNS

OBJECTIVE: Quantitative saccadic testing is a non-invasive method of evaluating the neural networks involved in the control of eye movements. The aim of this study is to provide a standardized and reproducible protocol for infrared oculography measurements of eye movements and analysis, which can be...

Descripción completa

Detalles Bibliográficos
Autores principales: Nij Bijvank, J. A., Petzold, A., Balk, L. J., Tan, H. S., Uitdehaag, B. M. J., Theodorou, M., van Rijn, L. J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6047815/
https://www.ncbi.nlm.nih.gov/pubmed/30011322
http://dx.doi.org/10.1371/journal.pone.0200695
_version_ 1783339995101134848
author Nij Bijvank, J. A.
Petzold, A.
Balk, L. J.
Tan, H. S.
Uitdehaag, B. M. J.
Theodorou, M.
van Rijn, L. J.
author_facet Nij Bijvank, J. A.
Petzold, A.
Balk, L. J.
Tan, H. S.
Uitdehaag, B. M. J.
Theodorou, M.
van Rijn, L. J.
author_sort Nij Bijvank, J. A.
collection PubMed
description OBJECTIVE: Quantitative saccadic testing is a non-invasive method of evaluating the neural networks involved in the control of eye movements. The aim of this study is to provide a standardized and reproducible protocol for infrared oculography measurements of eye movements and analysis, which can be applied for various diseases in a multicenter setting. METHODS: Development of a protocol to Demonstrate Eye Movement Networks with Saccades (DEMoNS) using infrared oculography. Automated analysis methods were used to calculate parameters describing the characteristics of the saccadic eye movements. The two measurements of the subjects were compared with descriptive and reproducibility statistics. RESULTS: Infrared oculography measurements of all subjects were performed using the DEMoNS protocol and various saccadic parameters were calculated automatically from 28 subjects. Saccadic parameters such as: peak velocity, latency and saccade pair ratios showed excellent reproducibility (intra-class correlation coefficients > 0.9). Parameters describing performance of more complex tasks showed moderate to good reproducibility (intra-class correlation coefficients 0.63–0.78). CONCLUSIONS: This study provides a standardized and transparent protocol for measuring and analyzing saccadic eye movements in a multicenter setting. The DEMoNS protocol details outcome measures for treatment trial which are of excellent reproducibility. The DEMoNS protocol can be applied to the study of saccadic eye movements in various neurodegenerative and motor diseases.
format Online
Article
Text
id pubmed-6047815
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-60478152018-07-26 A standardized protocol for quantification of saccadic eye movements: DEMoNS Nij Bijvank, J. A. Petzold, A. Balk, L. J. Tan, H. S. Uitdehaag, B. M. J. Theodorou, M. van Rijn, L. J. PLoS One Research Article OBJECTIVE: Quantitative saccadic testing is a non-invasive method of evaluating the neural networks involved in the control of eye movements. The aim of this study is to provide a standardized and reproducible protocol for infrared oculography measurements of eye movements and analysis, which can be applied for various diseases in a multicenter setting. METHODS: Development of a protocol to Demonstrate Eye Movement Networks with Saccades (DEMoNS) using infrared oculography. Automated analysis methods were used to calculate parameters describing the characteristics of the saccadic eye movements. The two measurements of the subjects were compared with descriptive and reproducibility statistics. RESULTS: Infrared oculography measurements of all subjects were performed using the DEMoNS protocol and various saccadic parameters were calculated automatically from 28 subjects. Saccadic parameters such as: peak velocity, latency and saccade pair ratios showed excellent reproducibility (intra-class correlation coefficients > 0.9). Parameters describing performance of more complex tasks showed moderate to good reproducibility (intra-class correlation coefficients 0.63–0.78). CONCLUSIONS: This study provides a standardized and transparent protocol for measuring and analyzing saccadic eye movements in a multicenter setting. The DEMoNS protocol details outcome measures for treatment trial which are of excellent reproducibility. The DEMoNS protocol can be applied to the study of saccadic eye movements in various neurodegenerative and motor diseases. Public Library of Science 2018-07-16 /pmc/articles/PMC6047815/ /pubmed/30011322 http://dx.doi.org/10.1371/journal.pone.0200695 Text en © 2018 Nij Bijvank et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Nij Bijvank, J. A.
Petzold, A.
Balk, L. J.
Tan, H. S.
Uitdehaag, B. M. J.
Theodorou, M.
van Rijn, L. J.
A standardized protocol for quantification of saccadic eye movements: DEMoNS
title A standardized protocol for quantification of saccadic eye movements: DEMoNS
title_full A standardized protocol for quantification of saccadic eye movements: DEMoNS
title_fullStr A standardized protocol for quantification of saccadic eye movements: DEMoNS
title_full_unstemmed A standardized protocol for quantification of saccadic eye movements: DEMoNS
title_short A standardized protocol for quantification of saccadic eye movements: DEMoNS
title_sort standardized protocol for quantification of saccadic eye movements: demons
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6047815/
https://www.ncbi.nlm.nih.gov/pubmed/30011322
http://dx.doi.org/10.1371/journal.pone.0200695
work_keys_str_mv AT nijbijvankja astandardizedprotocolforquantificationofsaccadiceyemovementsdemons
AT petzolda astandardizedprotocolforquantificationofsaccadiceyemovementsdemons
AT balklj astandardizedprotocolforquantificationofsaccadiceyemovementsdemons
AT tanhs astandardizedprotocolforquantificationofsaccadiceyemovementsdemons
AT uitdehaagbmj astandardizedprotocolforquantificationofsaccadiceyemovementsdemons
AT theodoroum astandardizedprotocolforquantificationofsaccadiceyemovementsdemons
AT vanrijnlj astandardizedprotocolforquantificationofsaccadiceyemovementsdemons
AT nijbijvankja standardizedprotocolforquantificationofsaccadiceyemovementsdemons
AT petzolda standardizedprotocolforquantificationofsaccadiceyemovementsdemons
AT balklj standardizedprotocolforquantificationofsaccadiceyemovementsdemons
AT tanhs standardizedprotocolforquantificationofsaccadiceyemovementsdemons
AT uitdehaagbmj standardizedprotocolforquantificationofsaccadiceyemovementsdemons
AT theodoroum standardizedprotocolforquantificationofsaccadiceyemovementsdemons
AT vanrijnlj standardizedprotocolforquantificationofsaccadiceyemovementsdemons