Cargando…
Upper gastrointestinal tract capsule endoscopy using a nurse-led protocol: First reported experience
AIM: To test the feasibility and performance of a novel upper gastrointestinal (GI) capsule endoscope using a nurse-led protocol. METHODS: We conducted a prospective cohort analysis of patients who declined gastroscopy (oesophagogastroduodenoscopy, OGD) but who consented to upper GI capsule endoscop...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Baishideng Publishing Group Inc
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6048428/ https://www.ncbi.nlm.nih.gov/pubmed/30018484 http://dx.doi.org/10.3748/wjg.v24.i26.2893 |
_version_ | 1783340109495533568 |
---|---|
author | Ching, Hey-Long Healy, Ailish Thurston, Victoria Hale, Melissa F Sidhu, Reena McAlindon, Mark E |
author_facet | Ching, Hey-Long Healy, Ailish Thurston, Victoria Hale, Melissa F Sidhu, Reena McAlindon, Mark E |
author_sort | Ching, Hey-Long |
collection | PubMed |
description | AIM: To test the feasibility and performance of a novel upper gastrointestinal (GI) capsule endoscope using a nurse-led protocol. METHODS: We conducted a prospective cohort analysis of patients who declined gastroscopy (oesophagogastroduodenoscopy, OGD) but who consented to upper GI capsule endoscopy. Patients swallowed the upper GI capsule following ingestion of 1 liter of water (containing simethicone). A series of positional changes were used to exploit the effects of water flow and move the upper GI capsule from one gravity-dependent area to another using a nurse-led protocol. Capsule transit time, video reading time, mucosal visualisation, pathology detection and patient tolerance was evaluated. RESULTS: Fifty patients were included in the study. The mean capsule transit times in the oesophagus and stomach were 28 s and 68 min respectively. Visualisation of the following major anatomical landmarks was achieved (graded 1-5: Poor to excellent): Oesophagus, 4.8 (± 0.5); gastro-oesophageal junction (GOJ), 4.8 (± 0.8); cardia, 4.8 (± 0.8); fundus, 3.8 (± 1.2); body, 4.5 (± 1); antrum, 4.5 (± 1); pylorus, 4.7 (± 0.8); duodenal bulb, 4.7 (± 0.7); second part of the duodenum (D2), 4.7 (± 1). The upper GI capsule reached D2 in 64% of patients. The mean video reading time was 48 min with standard playback mode and 20 min using Quickview (P = 0.0001). No pathology was missed using Quickview. Procedural tolerance was excellent. No complications were seen with the upper GI capsule. CONCLUSION: The upper GI capsule achieved excellent views of the upper GI tract. Future studies should compare the diagnostic accuracy between upper GI capsule and OGD. |
format | Online Article Text |
id | pubmed-6048428 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Baishideng Publishing Group Inc |
record_format | MEDLINE/PubMed |
spelling | pubmed-60484282018-07-17 Upper gastrointestinal tract capsule endoscopy using a nurse-led protocol: First reported experience Ching, Hey-Long Healy, Ailish Thurston, Victoria Hale, Melissa F Sidhu, Reena McAlindon, Mark E World J Gastroenterol Observational Study AIM: To test the feasibility and performance of a novel upper gastrointestinal (GI) capsule endoscope using a nurse-led protocol. METHODS: We conducted a prospective cohort analysis of patients who declined gastroscopy (oesophagogastroduodenoscopy, OGD) but who consented to upper GI capsule endoscopy. Patients swallowed the upper GI capsule following ingestion of 1 liter of water (containing simethicone). A series of positional changes were used to exploit the effects of water flow and move the upper GI capsule from one gravity-dependent area to another using a nurse-led protocol. Capsule transit time, video reading time, mucosal visualisation, pathology detection and patient tolerance was evaluated. RESULTS: Fifty patients were included in the study. The mean capsule transit times in the oesophagus and stomach were 28 s and 68 min respectively. Visualisation of the following major anatomical landmarks was achieved (graded 1-5: Poor to excellent): Oesophagus, 4.8 (± 0.5); gastro-oesophageal junction (GOJ), 4.8 (± 0.8); cardia, 4.8 (± 0.8); fundus, 3.8 (± 1.2); body, 4.5 (± 1); antrum, 4.5 (± 1); pylorus, 4.7 (± 0.8); duodenal bulb, 4.7 (± 0.7); second part of the duodenum (D2), 4.7 (± 1). The upper GI capsule reached D2 in 64% of patients. The mean video reading time was 48 min with standard playback mode and 20 min using Quickview (P = 0.0001). No pathology was missed using Quickview. Procedural tolerance was excellent. No complications were seen with the upper GI capsule. CONCLUSION: The upper GI capsule achieved excellent views of the upper GI tract. Future studies should compare the diagnostic accuracy between upper GI capsule and OGD. Baishideng Publishing Group Inc 2018-07-14 2018-07-14 /pmc/articles/PMC6048428/ /pubmed/30018484 http://dx.doi.org/10.3748/wjg.v24.i26.2893 Text en ©The Author(s) 2018. Published by Baishideng Publishing Group Inc. All rights reserved. http://creativecommons.org/licenses/by-nc/4.0/ This article is an open-access article which was selected by an in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. |
spellingShingle | Observational Study Ching, Hey-Long Healy, Ailish Thurston, Victoria Hale, Melissa F Sidhu, Reena McAlindon, Mark E Upper gastrointestinal tract capsule endoscopy using a nurse-led protocol: First reported experience |
title | Upper gastrointestinal tract capsule endoscopy using a nurse-led protocol: First reported experience |
title_full | Upper gastrointestinal tract capsule endoscopy using a nurse-led protocol: First reported experience |
title_fullStr | Upper gastrointestinal tract capsule endoscopy using a nurse-led protocol: First reported experience |
title_full_unstemmed | Upper gastrointestinal tract capsule endoscopy using a nurse-led protocol: First reported experience |
title_short | Upper gastrointestinal tract capsule endoscopy using a nurse-led protocol: First reported experience |
title_sort | upper gastrointestinal tract capsule endoscopy using a nurse-led protocol: first reported experience |
topic | Observational Study |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6048428/ https://www.ncbi.nlm.nih.gov/pubmed/30018484 http://dx.doi.org/10.3748/wjg.v24.i26.2893 |
work_keys_str_mv | AT chingheylong uppergastrointestinaltractcapsuleendoscopyusinganurseledprotocolfirstreportedexperience AT healyailish uppergastrointestinaltractcapsuleendoscopyusinganurseledprotocolfirstreportedexperience AT thurstonvictoria uppergastrointestinaltractcapsuleendoscopyusinganurseledprotocolfirstreportedexperience AT halemelissaf uppergastrointestinaltractcapsuleendoscopyusinganurseledprotocolfirstreportedexperience AT sidhureena uppergastrointestinaltractcapsuleendoscopyusinganurseledprotocolfirstreportedexperience AT mcalindonmarke uppergastrointestinaltractcapsuleendoscopyusinganurseledprotocolfirstreportedexperience |