Converting Treatment Plans From Helical Tomotherapy to L-Shape Linac: Clinical Workflow and Dosimetric Evaluation

This work evaluated a commercial fallback planning workflow designed to provide cross-platform treatment planning and delivery. A total of 27 helical tomotherapy intensity-modulated radiotherapy plans covering 4 anatomical sites were selected, including 7 brain, 5 unilateral head and neck, 5 bilater...

Descripción completa

Detalles Bibliográficos
Autores principales: Yuan, Zilong, Nair, Chithra Kumaran, Benedict, Stanley H., Valicenti, Richard K., Rao, Shyam, Fragoso, Ruben C., Wright, Cari, Qiu, Jianfeng, Rong, Yi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6048611/
https://www.ncbi.nlm.nih.gov/pubmed/29986638
http://dx.doi.org/10.1177/1533033818785279
_version_ 1783340128427573248
author Yuan, Zilong
Nair, Chithra Kumaran
Benedict, Stanley H.
Valicenti, Richard K.
Rao, Shyam
Fragoso, Ruben C.
Wright, Cari
Qiu, Jianfeng
Rong, Yi
author_facet Yuan, Zilong
Nair, Chithra Kumaran
Benedict, Stanley H.
Valicenti, Richard K.
Rao, Shyam
Fragoso, Ruben C.
Wright, Cari
Qiu, Jianfeng
Rong, Yi
author_sort Yuan, Zilong
collection PubMed
description This work evaluated a commercial fallback planning workflow designed to provide cross-platform treatment planning and delivery. A total of 27 helical tomotherapy intensity-modulated radiotherapy plans covering 4 anatomical sites were selected, including 7 brain, 5 unilateral head and neck, 5 bilateral head and neck, 5 pelvis, and 5 prostate cases. All helical tomotherapy plans were converted to 7-field/9-field intensity-modulated radiotherapy and volumetric-modulated radiotherapy plans through fallback dose-mimicking algorithm using a 6-MV beam model. The planning target volume (PTV) coverage (D (1), D (99), and homogeneity index) and organs at risk dose constraints were evaluated and compared. Overall, all 3 techniques resulted in relatively inferior target dose coverage compared to helical tomotherapy plans, with higher homogeneity index and maximum dose. The organs at risk dose ratio of fallback to helical tomotherapy plans covered a wide spectrum, from 0.87 to 1.11 on average for all sites, with fallback plans being superior for brain, pelvis, and prostate sites. The quality of fallback plans depends on the delivery technique, field numbers, and angles, as well as user selection of structures for organs at risk. In actual clinical scenario, fallback plans would typically be needed for 1 to 5 fractions of a treatment course in the event of machine breakdown. Our results suggested that <1% dose variance can be introduced in target coverage and/or organs at risk from fallback plans. The presented clinical workflow showed that the fallback plan generation typically takes 10 to 20 minutes per case. Fallback planning provides an expeditious and effective strategy for transferring patients cross platforms, and minimizing the untold risk of a patient missing treatment(s).
format Online
Article
Text
id pubmed-6048611
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-60486112018-07-20 Converting Treatment Plans From Helical Tomotherapy to L-Shape Linac: Clinical Workflow and Dosimetric Evaluation Yuan, Zilong Nair, Chithra Kumaran Benedict, Stanley H. Valicenti, Richard K. Rao, Shyam Fragoso, Ruben C. Wright, Cari Qiu, Jianfeng Rong, Yi Technol Cancer Res Treat Original Article This work evaluated a commercial fallback planning workflow designed to provide cross-platform treatment planning and delivery. A total of 27 helical tomotherapy intensity-modulated radiotherapy plans covering 4 anatomical sites were selected, including 7 brain, 5 unilateral head and neck, 5 bilateral head and neck, 5 pelvis, and 5 prostate cases. All helical tomotherapy plans were converted to 7-field/9-field intensity-modulated radiotherapy and volumetric-modulated radiotherapy plans through fallback dose-mimicking algorithm using a 6-MV beam model. The planning target volume (PTV) coverage (D (1), D (99), and homogeneity index) and organs at risk dose constraints were evaluated and compared. Overall, all 3 techniques resulted in relatively inferior target dose coverage compared to helical tomotherapy plans, with higher homogeneity index and maximum dose. The organs at risk dose ratio of fallback to helical tomotherapy plans covered a wide spectrum, from 0.87 to 1.11 on average for all sites, with fallback plans being superior for brain, pelvis, and prostate sites. The quality of fallback plans depends on the delivery technique, field numbers, and angles, as well as user selection of structures for organs at risk. In actual clinical scenario, fallback plans would typically be needed for 1 to 5 fractions of a treatment course in the event of machine breakdown. Our results suggested that <1% dose variance can be introduced in target coverage and/or organs at risk from fallback plans. The presented clinical workflow showed that the fallback plan generation typically takes 10 to 20 minutes per case. Fallback planning provides an expeditious and effective strategy for transferring patients cross platforms, and minimizing the untold risk of a patient missing treatment(s). SAGE Publications 2018-07-09 /pmc/articles/PMC6048611/ /pubmed/29986638 http://dx.doi.org/10.1177/1533033818785279 Text en © The Author(s) 2018 http://creativecommons.org/licenses/by-nc/4.0/ This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (http://www.creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Original Article
Yuan, Zilong
Nair, Chithra Kumaran
Benedict, Stanley H.
Valicenti, Richard K.
Rao, Shyam
Fragoso, Ruben C.
Wright, Cari
Qiu, Jianfeng
Rong, Yi
Converting Treatment Plans From Helical Tomotherapy to L-Shape Linac: Clinical Workflow and Dosimetric Evaluation
title Converting Treatment Plans From Helical Tomotherapy to L-Shape Linac: Clinical Workflow and Dosimetric Evaluation
title_full Converting Treatment Plans From Helical Tomotherapy to L-Shape Linac: Clinical Workflow and Dosimetric Evaluation
title_fullStr Converting Treatment Plans From Helical Tomotherapy to L-Shape Linac: Clinical Workflow and Dosimetric Evaluation
title_full_unstemmed Converting Treatment Plans From Helical Tomotherapy to L-Shape Linac: Clinical Workflow and Dosimetric Evaluation
title_short Converting Treatment Plans From Helical Tomotherapy to L-Shape Linac: Clinical Workflow and Dosimetric Evaluation
title_sort converting treatment plans from helical tomotherapy to l-shape linac: clinical workflow and dosimetric evaluation
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6048611/
https://www.ncbi.nlm.nih.gov/pubmed/29986638
http://dx.doi.org/10.1177/1533033818785279
work_keys_str_mv AT yuanzilong convertingtreatmentplansfromhelicaltomotherapytolshapelinacclinicalworkflowanddosimetricevaluation
AT nairchithrakumaran convertingtreatmentplansfromhelicaltomotherapytolshapelinacclinicalworkflowanddosimetricevaluation
AT benedictstanleyh convertingtreatmentplansfromhelicaltomotherapytolshapelinacclinicalworkflowanddosimetricevaluation
AT valicentirichardk convertingtreatmentplansfromhelicaltomotherapytolshapelinacclinicalworkflowanddosimetricevaluation
AT raoshyam convertingtreatmentplansfromhelicaltomotherapytolshapelinacclinicalworkflowanddosimetricevaluation
AT fragosorubenc convertingtreatmentplansfromhelicaltomotherapytolshapelinacclinicalworkflowanddosimetricevaluation
AT wrightcari convertingtreatmentplansfromhelicaltomotherapytolshapelinacclinicalworkflowanddosimetricevaluation
AT qiujianfeng convertingtreatmentplansfromhelicaltomotherapytolshapelinacclinicalworkflowanddosimetricevaluation
AT rongyi convertingtreatmentplansfromhelicaltomotherapytolshapelinacclinicalworkflowanddosimetricevaluation