Cargando…
Effectiveness and Safety of Simultaneous Integrated Boost-Proton Beam Therapy for Localized Pancreatic Cancer
PURPOSE: To evaluate the clinical effectiveness and feasibility of simultaneous integrated boost-proton beam therapy in patients with localized pancreatic cancer. METHODS: Thirty-seven patients with localized pancreatic cancer underwent simultaneous integrated boost-proton beam therapy, and 8 (21.6%...
Autores principales: | , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6048612/ https://www.ncbi.nlm.nih.gov/pubmed/29962281 http://dx.doi.org/10.1177/1533033818783879 |
_version_ | 1783340128665600000 |
---|---|
author | Kim, Tae Hyun Lee, Woo Jin Woo, Sang Myung Kim, Hyunjung Oh, Eun Sang Lee, Ju Hee Han, Sung-Sik Park, Sang-Jae Suh, Yang-Gun Moon, Sung Ho Kim, Sang Soo Kim, Dae Yong |
author_facet | Kim, Tae Hyun Lee, Woo Jin Woo, Sang Myung Kim, Hyunjung Oh, Eun Sang Lee, Ju Hee Han, Sung-Sik Park, Sang-Jae Suh, Yang-Gun Moon, Sung Ho Kim, Sang Soo Kim, Dae Yong |
author_sort | Kim, Tae Hyun |
collection | PubMed |
description | PURPOSE: To evaluate the clinical effectiveness and feasibility of simultaneous integrated boost-proton beam therapy in patients with localized pancreatic cancer. METHODS: Thirty-seven patients with localized pancreatic cancer underwent simultaneous integrated boost-proton beam therapy, and 8 (21.6%) patients received induction chemotherapy. The internal target volume was obtained by summing the gross tumor volumes in exhalation phase computed tomography images. Planning target volume 1 included internal target volume plus 3 to 5 mm margins, excluding the 5 mm expanded volume of gastrointestinal structures, and planning target volume 2 included the internal target volume plus 7 to 12 mm margins. The prescribed doses to planning target volume 1 and planning target volume 2 were 45 GyE (equivalent dose in 2 Gy, 54.4 GyE(10)) and 30 GyE (equivalent dose in 2 Gy, 32.5 GyE(10)) in 10 fractions, respectively. RESULTS: Overall, treatment was well tolerated, with no grade of toxicity ≥3. Median overall survival was 19.3 months, and 1-year local progression-free survival, relapse-free survival, and overall survival rates were 64.8%, 33.2%, and 75.7%, respectively. Patients treated with simultaneous integrated boost-proton beam therapy after induction chemotherapy had a significantly higher median overall survival time compared to those with simultaneous integrated boost-proton beam therapy alone (21.6 months vs 16.7 months, P = .031). Multivariate analysis showed that induction chemotherapy was a significant factor for overall survival (P < .05). CONCLUSIONS: Simultaneous integrated boost-proton beam therapy could be feasible and promising for patients with localized pancreatic cancer. |
format | Online Article Text |
id | pubmed-6048612 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | SAGE Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-60486122018-07-20 Effectiveness and Safety of Simultaneous Integrated Boost-Proton Beam Therapy for Localized Pancreatic Cancer Kim, Tae Hyun Lee, Woo Jin Woo, Sang Myung Kim, Hyunjung Oh, Eun Sang Lee, Ju Hee Han, Sung-Sik Park, Sang-Jae Suh, Yang-Gun Moon, Sung Ho Kim, Sang Soo Kim, Dae Yong Technol Cancer Res Treat Original Article PURPOSE: To evaluate the clinical effectiveness and feasibility of simultaneous integrated boost-proton beam therapy in patients with localized pancreatic cancer. METHODS: Thirty-seven patients with localized pancreatic cancer underwent simultaneous integrated boost-proton beam therapy, and 8 (21.6%) patients received induction chemotherapy. The internal target volume was obtained by summing the gross tumor volumes in exhalation phase computed tomography images. Planning target volume 1 included internal target volume plus 3 to 5 mm margins, excluding the 5 mm expanded volume of gastrointestinal structures, and planning target volume 2 included the internal target volume plus 7 to 12 mm margins. The prescribed doses to planning target volume 1 and planning target volume 2 were 45 GyE (equivalent dose in 2 Gy, 54.4 GyE(10)) and 30 GyE (equivalent dose in 2 Gy, 32.5 GyE(10)) in 10 fractions, respectively. RESULTS: Overall, treatment was well tolerated, with no grade of toxicity ≥3. Median overall survival was 19.3 months, and 1-year local progression-free survival, relapse-free survival, and overall survival rates were 64.8%, 33.2%, and 75.7%, respectively. Patients treated with simultaneous integrated boost-proton beam therapy after induction chemotherapy had a significantly higher median overall survival time compared to those with simultaneous integrated boost-proton beam therapy alone (21.6 months vs 16.7 months, P = .031). Multivariate analysis showed that induction chemotherapy was a significant factor for overall survival (P < .05). CONCLUSIONS: Simultaneous integrated boost-proton beam therapy could be feasible and promising for patients with localized pancreatic cancer. SAGE Publications 2018-07-01 /pmc/articles/PMC6048612/ /pubmed/29962281 http://dx.doi.org/10.1177/1533033818783879 Text en © The Author(s) 2018 http://creativecommons.org/licenses/by/4.0/ This article is distributed under the terms of the Creative Commons Attribution 4.0 License (http://www.creativecommons.org/licenses/by/4.0/) which permits any use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage). |
spellingShingle | Original Article Kim, Tae Hyun Lee, Woo Jin Woo, Sang Myung Kim, Hyunjung Oh, Eun Sang Lee, Ju Hee Han, Sung-Sik Park, Sang-Jae Suh, Yang-Gun Moon, Sung Ho Kim, Sang Soo Kim, Dae Yong Effectiveness and Safety of Simultaneous Integrated Boost-Proton Beam Therapy for Localized Pancreatic Cancer |
title | Effectiveness and Safety of Simultaneous Integrated Boost-Proton Beam Therapy
for Localized Pancreatic Cancer |
title_full | Effectiveness and Safety of Simultaneous Integrated Boost-Proton Beam Therapy
for Localized Pancreatic Cancer |
title_fullStr | Effectiveness and Safety of Simultaneous Integrated Boost-Proton Beam Therapy
for Localized Pancreatic Cancer |
title_full_unstemmed | Effectiveness and Safety of Simultaneous Integrated Boost-Proton Beam Therapy
for Localized Pancreatic Cancer |
title_short | Effectiveness and Safety of Simultaneous Integrated Boost-Proton Beam Therapy
for Localized Pancreatic Cancer |
title_sort | effectiveness and safety of simultaneous integrated boost-proton beam therapy
for localized pancreatic cancer |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6048612/ https://www.ncbi.nlm.nih.gov/pubmed/29962281 http://dx.doi.org/10.1177/1533033818783879 |
work_keys_str_mv | AT kimtaehyun effectivenessandsafetyofsimultaneousintegratedboostprotonbeamtherapyforlocalizedpancreaticcancer AT leewoojin effectivenessandsafetyofsimultaneousintegratedboostprotonbeamtherapyforlocalizedpancreaticcancer AT woosangmyung effectivenessandsafetyofsimultaneousintegratedboostprotonbeamtherapyforlocalizedpancreaticcancer AT kimhyunjung effectivenessandsafetyofsimultaneousintegratedboostprotonbeamtherapyforlocalizedpancreaticcancer AT oheunsang effectivenessandsafetyofsimultaneousintegratedboostprotonbeamtherapyforlocalizedpancreaticcancer AT leejuhee effectivenessandsafetyofsimultaneousintegratedboostprotonbeamtherapyforlocalizedpancreaticcancer AT hansungsik effectivenessandsafetyofsimultaneousintegratedboostprotonbeamtherapyforlocalizedpancreaticcancer AT parksangjae effectivenessandsafetyofsimultaneousintegratedboostprotonbeamtherapyforlocalizedpancreaticcancer AT suhyanggun effectivenessandsafetyofsimultaneousintegratedboostprotonbeamtherapyforlocalizedpancreaticcancer AT moonsungho effectivenessandsafetyofsimultaneousintegratedboostprotonbeamtherapyforlocalizedpancreaticcancer AT kimsangsoo effectivenessandsafetyofsimultaneousintegratedboostprotonbeamtherapyforlocalizedpancreaticcancer AT kimdaeyong effectivenessandsafetyofsimultaneousintegratedboostprotonbeamtherapyforlocalizedpancreaticcancer |