A multi-band double-inversion radial fast spin-echo technique for T2 cardiovascular magnetic resonance mapping of the heart

BACKGROUND: Double inversion recovery (DIR) fast spin-echo (FSE) cardiovascular magnetic resonance (CMR) sequences are used clinically for black-blood T2-weighted imaging. However, these sequences suffer from slice inefficiency due to the non-selective inversion pulses. We propose a multi-band (MB)...

Descripción completa

Detalles Bibliográficos
Autores principales: Keerthivasan, Mahesh Bharath, Mandava, Sagar, Johnson, Kevin, Avery, Ryan, Janardhanan, Rajesh, Martin, Diego R., Bilgin, Ali, Altbach, Maria I.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6052643/
https://www.ncbi.nlm.nih.gov/pubmed/30025523
http://dx.doi.org/10.1186/s12968-018-0470-y
_version_ 1783340699095138304
author Keerthivasan, Mahesh Bharath
Mandava, Sagar
Johnson, Kevin
Avery, Ryan
Janardhanan, Rajesh
Martin, Diego R.
Bilgin, Ali
Altbach, Maria I.
author_facet Keerthivasan, Mahesh Bharath
Mandava, Sagar
Johnson, Kevin
Avery, Ryan
Janardhanan, Rajesh
Martin, Diego R.
Bilgin, Ali
Altbach, Maria I.
author_sort Keerthivasan, Mahesh Bharath
collection PubMed
description BACKGROUND: Double inversion recovery (DIR) fast spin-echo (FSE) cardiovascular magnetic resonance (CMR) sequences are used clinically for black-blood T2-weighted imaging. However, these sequences suffer from slice inefficiency due to the non-selective inversion pulses. We propose a multi-band (MB) encoded DIR radial FSE (MB-DIR-RADFSE) technique to simultaneously excite two slices. This sequence has improved signal-to-noise ratio per unit time compared to a single slice excitation. It is also motion robust and enables the reconstruction of high-resolution black-blood T2-weighted images and T2 maps for the excited slices. METHODS: Hadamard encoded MB pulses were used in MB-DIR-RADFSE to simultaneously excite two slices. A principal component based iterative reconstruction was used to jointly reconstruct black-blood T2-weighted images and T2 maps. Phantom and in vivo experiments were performed to evaluate T2 mapping performance and results were compared to a T2-prepared balanced steady state free precession (bSSFP) method. The inter-segment variability of the T2 maps were assessed using data acquired on healthy subjects. A reproducibility study was performed to evaluate reproducibility of the proposed technique. RESULTS: Phantom experiments show that the T2 values estimated from MB-DIR-RADFSE are comparable to the spin-echo based reference, while T2-prepared bSSFP over-estimated T2 values. The relative contrast of the black-blood images from the multi-band scheme was comparable to those from a single slice acquisition. The myocardial segment analysis on 8 healthy subjects indicated a significant difference (p-value < 0.01) in the T2 estimates from the apical slice when compared to the mid-ventricular slice. The mean T2 estimate from 12 subjects obtained using T2-prepared bSSFP was significantly higher (p-value = 0.012) compared to MB-DIR-RADFSE, consistent with the phantom results. The Bland-Altman analysis showed excellent reproducibility between the MB-DIR-RADFSE measurements, with a mean T2 difference of 0.12 ms and coefficient of reproducibility of 2.07 in 15 clinical subjects. The utility of this technique is demonstrated in two subjects where the T2 maps show elevated values in regions of pathology. CONCLUSIONS: The use of multi-band pulses for excitation improves the slice efficiency of the double inversion fast spin-echo pulse sequence. The use of a radial trajectory and a joint reconstruction framework allows reconstruction of TE images and T2 maps for the excited slices.
format Online
Article
Text
id pubmed-6052643
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-60526432018-07-20 A multi-band double-inversion radial fast spin-echo technique for T2 cardiovascular magnetic resonance mapping of the heart Keerthivasan, Mahesh Bharath Mandava, Sagar Johnson, Kevin Avery, Ryan Janardhanan, Rajesh Martin, Diego R. Bilgin, Ali Altbach, Maria I. J Cardiovasc Magn Reson Technical Notes BACKGROUND: Double inversion recovery (DIR) fast spin-echo (FSE) cardiovascular magnetic resonance (CMR) sequences are used clinically for black-blood T2-weighted imaging. However, these sequences suffer from slice inefficiency due to the non-selective inversion pulses. We propose a multi-band (MB) encoded DIR radial FSE (MB-DIR-RADFSE) technique to simultaneously excite two slices. This sequence has improved signal-to-noise ratio per unit time compared to a single slice excitation. It is also motion robust and enables the reconstruction of high-resolution black-blood T2-weighted images and T2 maps for the excited slices. METHODS: Hadamard encoded MB pulses were used in MB-DIR-RADFSE to simultaneously excite two slices. A principal component based iterative reconstruction was used to jointly reconstruct black-blood T2-weighted images and T2 maps. Phantom and in vivo experiments were performed to evaluate T2 mapping performance and results were compared to a T2-prepared balanced steady state free precession (bSSFP) method. The inter-segment variability of the T2 maps were assessed using data acquired on healthy subjects. A reproducibility study was performed to evaluate reproducibility of the proposed technique. RESULTS: Phantom experiments show that the T2 values estimated from MB-DIR-RADFSE are comparable to the spin-echo based reference, while T2-prepared bSSFP over-estimated T2 values. The relative contrast of the black-blood images from the multi-band scheme was comparable to those from a single slice acquisition. The myocardial segment analysis on 8 healthy subjects indicated a significant difference (p-value < 0.01) in the T2 estimates from the apical slice when compared to the mid-ventricular slice. The mean T2 estimate from 12 subjects obtained using T2-prepared bSSFP was significantly higher (p-value = 0.012) compared to MB-DIR-RADFSE, consistent with the phantom results. The Bland-Altman analysis showed excellent reproducibility between the MB-DIR-RADFSE measurements, with a mean T2 difference of 0.12 ms and coefficient of reproducibility of 2.07 in 15 clinical subjects. The utility of this technique is demonstrated in two subjects where the T2 maps show elevated values in regions of pathology. CONCLUSIONS: The use of multi-band pulses for excitation improves the slice efficiency of the double inversion fast spin-echo pulse sequence. The use of a radial trajectory and a joint reconstruction framework allows reconstruction of TE images and T2 maps for the excited slices. BioMed Central 2018-07-19 /pmc/articles/PMC6052643/ /pubmed/30025523 http://dx.doi.org/10.1186/s12968-018-0470-y Text en © The Author(s). 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Technical Notes
Keerthivasan, Mahesh Bharath
Mandava, Sagar
Johnson, Kevin
Avery, Ryan
Janardhanan, Rajesh
Martin, Diego R.
Bilgin, Ali
Altbach, Maria I.
A multi-band double-inversion radial fast spin-echo technique for T2 cardiovascular magnetic resonance mapping of the heart
title A multi-band double-inversion radial fast spin-echo technique for T2 cardiovascular magnetic resonance mapping of the heart
title_full A multi-band double-inversion radial fast spin-echo technique for T2 cardiovascular magnetic resonance mapping of the heart
title_fullStr A multi-band double-inversion radial fast spin-echo technique for T2 cardiovascular magnetic resonance mapping of the heart
title_full_unstemmed A multi-band double-inversion radial fast spin-echo technique for T2 cardiovascular magnetic resonance mapping of the heart
title_short A multi-band double-inversion radial fast spin-echo technique for T2 cardiovascular magnetic resonance mapping of the heart
title_sort multi-band double-inversion radial fast spin-echo technique for t2 cardiovascular magnetic resonance mapping of the heart
topic Technical Notes
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6052643/
https://www.ncbi.nlm.nih.gov/pubmed/30025523
http://dx.doi.org/10.1186/s12968-018-0470-y
work_keys_str_mv AT keerthivasanmaheshbharath amultibanddoubleinversionradialfastspinechotechniquefort2cardiovascularmagneticresonancemappingoftheheart
AT mandavasagar amultibanddoubleinversionradialfastspinechotechniquefort2cardiovascularmagneticresonancemappingoftheheart
AT johnsonkevin amultibanddoubleinversionradialfastspinechotechniquefort2cardiovascularmagneticresonancemappingoftheheart
AT averyryan amultibanddoubleinversionradialfastspinechotechniquefort2cardiovascularmagneticresonancemappingoftheheart
AT janardhananrajesh amultibanddoubleinversionradialfastspinechotechniquefort2cardiovascularmagneticresonancemappingoftheheart
AT martindiegor amultibanddoubleinversionradialfastspinechotechniquefort2cardiovascularmagneticresonancemappingoftheheart
AT bilginali amultibanddoubleinversionradialfastspinechotechniquefort2cardiovascularmagneticresonancemappingoftheheart
AT altbachmariai amultibanddoubleinversionradialfastspinechotechniquefort2cardiovascularmagneticresonancemappingoftheheart
AT keerthivasanmaheshbharath multibanddoubleinversionradialfastspinechotechniquefort2cardiovascularmagneticresonancemappingoftheheart
AT mandavasagar multibanddoubleinversionradialfastspinechotechniquefort2cardiovascularmagneticresonancemappingoftheheart
AT johnsonkevin multibanddoubleinversionradialfastspinechotechniquefort2cardiovascularmagneticresonancemappingoftheheart
AT averyryan multibanddoubleinversionradialfastspinechotechniquefort2cardiovascularmagneticresonancemappingoftheheart
AT janardhananrajesh multibanddoubleinversionradialfastspinechotechniquefort2cardiovascularmagneticresonancemappingoftheheart
AT martindiegor multibanddoubleinversionradialfastspinechotechniquefort2cardiovascularmagneticresonancemappingoftheheart
AT bilginali multibanddoubleinversionradialfastspinechotechniquefort2cardiovascularmagneticresonancemappingoftheheart
AT altbachmariai multibanddoubleinversionradialfastspinechotechniquefort2cardiovascularmagneticresonancemappingoftheheart