Cargando…

Red blood cell aggregates and their effect on non-Newtonian blood viscosity at low hematocrit in a two-fluid low shear rate microfluidic system

Red blood cells (RBCs) are the most abundant cells in human blood. Remarkably RBCs deform and bridge together to form aggregates under very low shear rates. The theory and mechanics behind aggregation are, however, not yet completely understood. The main objective of this work is to quantify and cha...

Descripción completa

Detalles Bibliográficos
Autores principales: Mehri, Rym, Mavriplis, Catherine, Fenech, Marianne
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6053157/
https://www.ncbi.nlm.nih.gov/pubmed/30024907
http://dx.doi.org/10.1371/journal.pone.0199911
_version_ 1783340767882772480
author Mehri, Rym
Mavriplis, Catherine
Fenech, Marianne
author_facet Mehri, Rym
Mavriplis, Catherine
Fenech, Marianne
author_sort Mehri, Rym
collection PubMed
description Red blood cells (RBCs) are the most abundant cells in human blood. Remarkably RBCs deform and bridge together to form aggregates under very low shear rates. The theory and mechanics behind aggregation are, however, not yet completely understood. The main objective of this work is to quantify and characterize RBC aggregates in order to enhance the current understanding of the non-Newtonian behaviour of blood in microcirculation. Suspensions of human blood were flowed and observed in vitro in poly-di-methyl-siloxane (PDMS) microchannels to characterize RBC aggregates. These microchannels were fabricated using standard photolithography methods. Experiments were performed using a micro particle image velocimetry (μPIV) system for shear rate measurements, coupled with a high-speed camera for flow visualization. RBC aggregate sizes were quantified in controlled and measurable shear rate environments for 5, 10 and 15% hematocrit. Aggregate sizes were determined using image processing techniques, while apparent viscosity was measured using optical viscometry. For the samples suspended at 5% H, aggregate size was not strongly correlated with shear rate. For the 10% H suspensions, in contrast, lowering the shear rate below 10 s(-1) resulted in a significant increase of RBC aggregate sizes. The viscosity was found to increase with decreasing shear rate and increasing hematocrit, exemplifying the established non-Newtonian shear-thinning behaviour of blood. Increase in aggregation size did not translate into a linear increase of the blood viscosity. Temperature was shown to affect blood viscosity as expected, however, no correlation for aggregate size with temperature was observed. Non-Newtonian parameters associated with power law and Carreau models were determined by fitting the experimental data and can be used towards the simple modeling of blood’s non-Newtonian behaviour in microcirculation. This work establishes a relationship between RBC aggregate sizes and corresponding shear rates and one between RBC aggregate sizes and apparent blood viscosity at body and room temperatures, in a microfluidic environment for low hematocrit. Effects of hematocrit, shear rate, viscosity and temperature on RBC aggregate sizes have been quantified.
format Online
Article
Text
id pubmed-6053157
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-60531572018-07-27 Red blood cell aggregates and their effect on non-Newtonian blood viscosity at low hematocrit in a two-fluid low shear rate microfluidic system Mehri, Rym Mavriplis, Catherine Fenech, Marianne PLoS One Research Article Red blood cells (RBCs) are the most abundant cells in human blood. Remarkably RBCs deform and bridge together to form aggregates under very low shear rates. The theory and mechanics behind aggregation are, however, not yet completely understood. The main objective of this work is to quantify and characterize RBC aggregates in order to enhance the current understanding of the non-Newtonian behaviour of blood in microcirculation. Suspensions of human blood were flowed and observed in vitro in poly-di-methyl-siloxane (PDMS) microchannels to characterize RBC aggregates. These microchannels were fabricated using standard photolithography methods. Experiments were performed using a micro particle image velocimetry (μPIV) system for shear rate measurements, coupled with a high-speed camera for flow visualization. RBC aggregate sizes were quantified in controlled and measurable shear rate environments for 5, 10 and 15% hematocrit. Aggregate sizes were determined using image processing techniques, while apparent viscosity was measured using optical viscometry. For the samples suspended at 5% H, aggregate size was not strongly correlated with shear rate. For the 10% H suspensions, in contrast, lowering the shear rate below 10 s(-1) resulted in a significant increase of RBC aggregate sizes. The viscosity was found to increase with decreasing shear rate and increasing hematocrit, exemplifying the established non-Newtonian shear-thinning behaviour of blood. Increase in aggregation size did not translate into a linear increase of the blood viscosity. Temperature was shown to affect blood viscosity as expected, however, no correlation for aggregate size with temperature was observed. Non-Newtonian parameters associated with power law and Carreau models were determined by fitting the experimental data and can be used towards the simple modeling of blood’s non-Newtonian behaviour in microcirculation. This work establishes a relationship between RBC aggregate sizes and corresponding shear rates and one between RBC aggregate sizes and apparent blood viscosity at body and room temperatures, in a microfluidic environment for low hematocrit. Effects of hematocrit, shear rate, viscosity and temperature on RBC aggregate sizes have been quantified. Public Library of Science 2018-07-19 /pmc/articles/PMC6053157/ /pubmed/30024907 http://dx.doi.org/10.1371/journal.pone.0199911 Text en © 2018 Mehri et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Mehri, Rym
Mavriplis, Catherine
Fenech, Marianne
Red blood cell aggregates and their effect on non-Newtonian blood viscosity at low hematocrit in a two-fluid low shear rate microfluidic system
title Red blood cell aggregates and their effect on non-Newtonian blood viscosity at low hematocrit in a two-fluid low shear rate microfluidic system
title_full Red blood cell aggregates and their effect on non-Newtonian blood viscosity at low hematocrit in a two-fluid low shear rate microfluidic system
title_fullStr Red blood cell aggregates and their effect on non-Newtonian blood viscosity at low hematocrit in a two-fluid low shear rate microfluidic system
title_full_unstemmed Red blood cell aggregates and their effect on non-Newtonian blood viscosity at low hematocrit in a two-fluid low shear rate microfluidic system
title_short Red blood cell aggregates and their effect on non-Newtonian blood viscosity at low hematocrit in a two-fluid low shear rate microfluidic system
title_sort red blood cell aggregates and their effect on non-newtonian blood viscosity at low hematocrit in a two-fluid low shear rate microfluidic system
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6053157/
https://www.ncbi.nlm.nih.gov/pubmed/30024907
http://dx.doi.org/10.1371/journal.pone.0199911
work_keys_str_mv AT mehrirym redbloodcellaggregatesandtheireffectonnonnewtonianbloodviscosityatlowhematocritinatwofluidlowshearratemicrofluidicsystem
AT mavripliscatherine redbloodcellaggregatesandtheireffectonnonnewtonianbloodviscosityatlowhematocritinatwofluidlowshearratemicrofluidicsystem
AT fenechmarianne redbloodcellaggregatesandtheireffectonnonnewtonianbloodviscosityatlowhematocritinatwofluidlowshearratemicrofluidicsystem