Precise Dispensing Technology Using Electroformed Tubes for Micro-Volume Blood Diagnosis
Precise dispensing of droplets is a crucial step for acquiring reliable blood diagnostic results. When the source sample volume is limited, the need for precise dispensing of submicroliter and nanoliter quantities is especially important. In this paper, we developed a positive-displacement high-prec...
Formato: | Online Artículo Texto |
---|---|
Lenguaje: | English |
Publicado: |
IEEE
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6054515/ https://www.ncbi.nlm.nih.gov/pubmed/30042905 http://dx.doi.org/10.1109/JTEHM.2018.2852664 |
_version_ | 1783341013429911552 |
---|---|
collection | PubMed |
description | Precise dispensing of droplets is a crucial step for acquiring reliable blood diagnostic results. When the source sample volume is limited, the need for precise dispensing of submicroliter and nanoliter quantities is especially important. In this paper, we developed a positive-displacement high-precision dispensing technique using a nickel electroformed tube with an inner diameter accuracy of [Formula: see text] or less. When dispensing variation of 100 nL was evaluated by using a photometric method, the most stable coefficients of variation (CV) were observed for a tube thickness of [Formula: see text] with hydrophobic treatment, where the average CV value was 1.3%, i.e., 1.3 nL. Furthermore, the glucose concentration of 100- and 200-nL animal-based control serum was colorimetrically measured using enzymatic reactions without drying and mixing reagents. The CV value was approximately 6.36% at 100 nL and 3.23% at 200 nL, suggesting that several biochemical panels can be precisely measured even from less than one drop of blood. This positive-displacement dispenser ensures zero contamination and almost-zero dead volume, thus it would be useful for multi-panel clinical blood testing. |
format | Online Article Text |
id | pubmed-6054515 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | IEEE |
record_format | MEDLINE/PubMed |
spelling | pubmed-60545152018-07-24 Precise Dispensing Technology Using Electroformed Tubes for Micro-Volume Blood Diagnosis IEEE J Transl Eng Health Med Article Precise dispensing of droplets is a crucial step for acquiring reliable blood diagnostic results. When the source sample volume is limited, the need for precise dispensing of submicroliter and nanoliter quantities is especially important. In this paper, we developed a positive-displacement high-precision dispensing technique using a nickel electroformed tube with an inner diameter accuracy of [Formula: see text] or less. When dispensing variation of 100 nL was evaluated by using a photometric method, the most stable coefficients of variation (CV) were observed for a tube thickness of [Formula: see text] with hydrophobic treatment, where the average CV value was 1.3%, i.e., 1.3 nL. Furthermore, the glucose concentration of 100- and 200-nL animal-based control serum was colorimetrically measured using enzymatic reactions without drying and mixing reagents. The CV value was approximately 6.36% at 100 nL and 3.23% at 200 nL, suggesting that several biochemical panels can be precisely measured even from less than one drop of blood. This positive-displacement dispenser ensures zero contamination and almost-zero dead volume, thus it would be useful for multi-panel clinical blood testing. IEEE 2016-07-04 /pmc/articles/PMC6054515/ /pubmed/30042905 http://dx.doi.org/10.1109/JTEHM.2018.2852664 Text en 2168-2372 © 2016 IEEE. Translations and content mining are permitted for academic research only. Personal use is also permitted, but republication/redistribution requires IEEE permission. See http://www.ieee.org/publications_standards/publications/rights/index.html for more information. |
spellingShingle | Article Precise Dispensing Technology Using Electroformed Tubes for Micro-Volume Blood Diagnosis |
title | Precise Dispensing Technology Using Electroformed Tubes for Micro-Volume Blood Diagnosis |
title_full | Precise Dispensing Technology Using Electroformed Tubes for Micro-Volume Blood Diagnosis |
title_fullStr | Precise Dispensing Technology Using Electroformed Tubes for Micro-Volume Blood Diagnosis |
title_full_unstemmed | Precise Dispensing Technology Using Electroformed Tubes for Micro-Volume Blood Diagnosis |
title_short | Precise Dispensing Technology Using Electroformed Tubes for Micro-Volume Blood Diagnosis |
title_sort | precise dispensing technology using electroformed tubes for micro-volume blood diagnosis |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6054515/ https://www.ncbi.nlm.nih.gov/pubmed/30042905 http://dx.doi.org/10.1109/JTEHM.2018.2852664 |
work_keys_str_mv | AT precisedispensingtechnologyusingelectroformedtubesformicrovolumeblooddiagnosis AT precisedispensingtechnologyusingelectroformedtubesformicrovolumeblooddiagnosis AT precisedispensingtechnologyusingelectroformedtubesformicrovolumeblooddiagnosis AT precisedispensingtechnologyusingelectroformedtubesformicrovolumeblooddiagnosis |