Cargando…
An Automated Draft Report Generator for Peripheral Blood Smear Examinations Based on Complete Blood Count Parameters
BACKGROUND: Complete blood count (CBC) results play an important role in peripheral blood smear (PBS) examinations. Many descriptions in PBS reports may simply be translated from CBC parameters. We developed a computer program that automatically generates a PBS draft report based on CBC parameters a...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Society for Laboratory Medicine
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6056392/ https://www.ncbi.nlm.nih.gov/pubmed/30027693 http://dx.doi.org/10.3343/alm.2018.38.6.512 |
_version_ | 1783341324374638592 |
---|---|
author | Kim, Young-gon Kwon, Jung Ah Moon, Yeonsook Park, Seong Jun Kim, Sangwook Lee, Hyun-A Ko, Sun-Young Chang, Eun-Ah Nam, Myung-Hyun Lim, Chae Seung Yoon, Soo-Young |
author_facet | Kim, Young-gon Kwon, Jung Ah Moon, Yeonsook Park, Seong Jun Kim, Sangwook Lee, Hyun-A Ko, Sun-Young Chang, Eun-Ah Nam, Myung-Hyun Lim, Chae Seung Yoon, Soo-Young |
author_sort | Kim, Young-gon |
collection | PubMed |
description | BACKGROUND: Complete blood count (CBC) results play an important role in peripheral blood smear (PBS) examinations. Many descriptions in PBS reports may simply be translated from CBC parameters. We developed a computer program that automatically generates a PBS draft report based on CBC parameters and age- and sex-matched reference ranges. METHODS: The Java programming language was used to develop a computer program that supports a graphical user interface. Four hematology analyzers from three different laboratories were tested: Sysmex XE-5000 (Sysmex, Kobe, Japan), Sysmex XN-9000 (Sysmex), DxH800 (Beckman Coulter, Brea, CA, USA), and ADVIA 2120i (Siemens Healthcare Diagnostics, Eschborn, Germany). Input data files containing 862 CBC results were generated from hematology analyzers, middlewares, or laboratory information systems. The draft reports were compared with the content of input data files. RESULTS: We developed a computer program that reads CBC results from a data file and automatically writes a draft PBS report. Age- and sex-matched reference ranges can be automatically applied. After examining PBS, users can modify the draft report based on microscopic findings. Recommendations such as suggestions for further evaluations are also provided based on morphological findings, and they can be modified by users. The program was compatible with all four hematology analyzers tested. CONCLUSIONS: Our program is expected to reduce the time required to manually incorporate CBC results into PBS reports. Systematic inclusion of CBC results could help improve the reliability and sensitivity of PBS examinations. |
format | Online Article Text |
id | pubmed-6056392 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | The Korean Society for Laboratory Medicine |
record_format | MEDLINE/PubMed |
spelling | pubmed-60563922018-11-01 An Automated Draft Report Generator for Peripheral Blood Smear Examinations Based on Complete Blood Count Parameters Kim, Young-gon Kwon, Jung Ah Moon, Yeonsook Park, Seong Jun Kim, Sangwook Lee, Hyun-A Ko, Sun-Young Chang, Eun-Ah Nam, Myung-Hyun Lim, Chae Seung Yoon, Soo-Young Ann Lab Med Original Article BACKGROUND: Complete blood count (CBC) results play an important role in peripheral blood smear (PBS) examinations. Many descriptions in PBS reports may simply be translated from CBC parameters. We developed a computer program that automatically generates a PBS draft report based on CBC parameters and age- and sex-matched reference ranges. METHODS: The Java programming language was used to develop a computer program that supports a graphical user interface. Four hematology analyzers from three different laboratories were tested: Sysmex XE-5000 (Sysmex, Kobe, Japan), Sysmex XN-9000 (Sysmex), DxH800 (Beckman Coulter, Brea, CA, USA), and ADVIA 2120i (Siemens Healthcare Diagnostics, Eschborn, Germany). Input data files containing 862 CBC results were generated from hematology analyzers, middlewares, or laboratory information systems. The draft reports were compared with the content of input data files. RESULTS: We developed a computer program that reads CBC results from a data file and automatically writes a draft PBS report. Age- and sex-matched reference ranges can be automatically applied. After examining PBS, users can modify the draft report based on microscopic findings. Recommendations such as suggestions for further evaluations are also provided based on morphological findings, and they can be modified by users. The program was compatible with all four hematology analyzers tested. CONCLUSIONS: Our program is expected to reduce the time required to manually incorporate CBC results into PBS reports. Systematic inclusion of CBC results could help improve the reliability and sensitivity of PBS examinations. The Korean Society for Laboratory Medicine 2018-11 2018-07-18 /pmc/articles/PMC6056392/ /pubmed/30027693 http://dx.doi.org/10.3343/alm.2018.38.6.512 Text en © The Korean Society for Laboratory Medicine http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Kim, Young-gon Kwon, Jung Ah Moon, Yeonsook Park, Seong Jun Kim, Sangwook Lee, Hyun-A Ko, Sun-Young Chang, Eun-Ah Nam, Myung-Hyun Lim, Chae Seung Yoon, Soo-Young An Automated Draft Report Generator for Peripheral Blood Smear Examinations Based on Complete Blood Count Parameters |
title | An Automated Draft Report Generator for Peripheral Blood Smear Examinations Based on Complete Blood Count Parameters |
title_full | An Automated Draft Report Generator for Peripheral Blood Smear Examinations Based on Complete Blood Count Parameters |
title_fullStr | An Automated Draft Report Generator for Peripheral Blood Smear Examinations Based on Complete Blood Count Parameters |
title_full_unstemmed | An Automated Draft Report Generator for Peripheral Blood Smear Examinations Based on Complete Blood Count Parameters |
title_short | An Automated Draft Report Generator for Peripheral Blood Smear Examinations Based on Complete Blood Count Parameters |
title_sort | automated draft report generator for peripheral blood smear examinations based on complete blood count parameters |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6056392/ https://www.ncbi.nlm.nih.gov/pubmed/30027693 http://dx.doi.org/10.3343/alm.2018.38.6.512 |
work_keys_str_mv | AT kimyounggon anautomateddraftreportgeneratorforperipheralbloodsmearexaminationsbasedoncompletebloodcountparameters AT kwonjungah anautomateddraftreportgeneratorforperipheralbloodsmearexaminationsbasedoncompletebloodcountparameters AT moonyeonsook anautomateddraftreportgeneratorforperipheralbloodsmearexaminationsbasedoncompletebloodcountparameters AT parkseongjun anautomateddraftreportgeneratorforperipheralbloodsmearexaminationsbasedoncompletebloodcountparameters AT kimsangwook anautomateddraftreportgeneratorforperipheralbloodsmearexaminationsbasedoncompletebloodcountparameters AT leehyuna anautomateddraftreportgeneratorforperipheralbloodsmearexaminationsbasedoncompletebloodcountparameters AT kosunyoung anautomateddraftreportgeneratorforperipheralbloodsmearexaminationsbasedoncompletebloodcountparameters AT changeunah anautomateddraftreportgeneratorforperipheralbloodsmearexaminationsbasedoncompletebloodcountparameters AT nammyunghyun anautomateddraftreportgeneratorforperipheralbloodsmearexaminationsbasedoncompletebloodcountparameters AT limchaeseung anautomateddraftreportgeneratorforperipheralbloodsmearexaminationsbasedoncompletebloodcountparameters AT yoonsooyoung anautomateddraftreportgeneratorforperipheralbloodsmearexaminationsbasedoncompletebloodcountparameters AT kimyounggon automateddraftreportgeneratorforperipheralbloodsmearexaminationsbasedoncompletebloodcountparameters AT kwonjungah automateddraftreportgeneratorforperipheralbloodsmearexaminationsbasedoncompletebloodcountparameters AT moonyeonsook automateddraftreportgeneratorforperipheralbloodsmearexaminationsbasedoncompletebloodcountparameters AT parkseongjun automateddraftreportgeneratorforperipheralbloodsmearexaminationsbasedoncompletebloodcountparameters AT kimsangwook automateddraftreportgeneratorforperipheralbloodsmearexaminationsbasedoncompletebloodcountparameters AT leehyuna automateddraftreportgeneratorforperipheralbloodsmearexaminationsbasedoncompletebloodcountparameters AT kosunyoung automateddraftreportgeneratorforperipheralbloodsmearexaminationsbasedoncompletebloodcountparameters AT changeunah automateddraftreportgeneratorforperipheralbloodsmearexaminationsbasedoncompletebloodcountparameters AT nammyunghyun automateddraftreportgeneratorforperipheralbloodsmearexaminationsbasedoncompletebloodcountparameters AT limchaeseung automateddraftreportgeneratorforperipheralbloodsmearexaminationsbasedoncompletebloodcountparameters AT yoonsooyoung automateddraftreportgeneratorforperipheralbloodsmearexaminationsbasedoncompletebloodcountparameters |