Cargando…

Data on treatment of sewage wastewater by electrocoagulation using punched aluminum electrode and characterization of generated sludge

The electrocoagulation setup must be optimized in order to design an economically feasible process. Therefore, in this work, the effect of the punched aluminum electrode on the performance of the electrocoagulation (EC) has been investigated. A series of experiments were performed for treatment of s...

Descripción completa

Detalles Bibliográficos
Autores principales: Khandegar, Vinita, Acharya, Sanigdha, Jain, Arinjay K.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6058665/
https://www.ncbi.nlm.nih.gov/pubmed/30050967
http://dx.doi.org/10.1016/j.dib.2018.04.020
_version_ 1783341741425819648
author Khandegar, Vinita
Acharya, Sanigdha
Jain, Arinjay K.
author_facet Khandegar, Vinita
Acharya, Sanigdha
Jain, Arinjay K.
author_sort Khandegar, Vinita
collection PubMed
description The electrocoagulation setup must be optimized in order to design an economically feasible process. Therefore, in this work, the effect of the punched aluminum electrode on the performance of the electrocoagulation (EC) has been investigated. A series of experiments were performed for treatment of sewage wastewater using plane electrode and compare with punched electrodes. Effect of contact time, voltage, electrode spacing and stirring speed has been optimized for removal of Biochemical oxygen demand (BOD) and Total dissolved solids (TDS). It was observed that the performance of electrocoagulation process increased using punched electrode. Also, the less operating cost noticed in punched electrode as compared to a plane electrode for (70–80%) removal of BOD and TDS. These data would be useful in designing of an EC reactor to obtain high removal efficiency at low energy consumption.
format Online
Article
Text
id pubmed-6058665
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-60586652018-07-26 Data on treatment of sewage wastewater by electrocoagulation using punched aluminum electrode and characterization of generated sludge Khandegar, Vinita Acharya, Sanigdha Jain, Arinjay K. Data Brief Environmental Sciences    The electrocoagulation setup must be optimized in order to design an economically feasible process. Therefore, in this work, the effect of the punched aluminum electrode on the performance of the electrocoagulation (EC) has been investigated. A series of experiments were performed for treatment of sewage wastewater using plane electrode and compare with punched electrodes. Effect of contact time, voltage, electrode spacing and stirring speed has been optimized for removal of Biochemical oxygen demand (BOD) and Total dissolved solids (TDS). It was observed that the performance of electrocoagulation process increased using punched electrode. Also, the less operating cost noticed in punched electrode as compared to a plane electrode for (70–80%) removal of BOD and TDS. These data would be useful in designing of an EC reactor to obtain high removal efficiency at low energy consumption. Elsevier 2018-04-11 /pmc/articles/PMC6058665/ /pubmed/30050967 http://dx.doi.org/10.1016/j.dib.2018.04.020 Text en © 2018 The Authors. Published by Elsevier Inc. http://creativecommons.org/licenses/by/4.0/ This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Environmental Sciences   
Khandegar, Vinita
Acharya, Sanigdha
Jain, Arinjay K.
Data on treatment of sewage wastewater by electrocoagulation using punched aluminum electrode and characterization of generated sludge
title Data on treatment of sewage wastewater by electrocoagulation using punched aluminum electrode and characterization of generated sludge
title_full Data on treatment of sewage wastewater by electrocoagulation using punched aluminum electrode and characterization of generated sludge
title_fullStr Data on treatment of sewage wastewater by electrocoagulation using punched aluminum electrode and characterization of generated sludge
title_full_unstemmed Data on treatment of sewage wastewater by electrocoagulation using punched aluminum electrode and characterization of generated sludge
title_short Data on treatment of sewage wastewater by electrocoagulation using punched aluminum electrode and characterization of generated sludge
title_sort data on treatment of sewage wastewater by electrocoagulation using punched aluminum electrode and characterization of generated sludge
topic Environmental Sciences   
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6058665/
https://www.ncbi.nlm.nih.gov/pubmed/30050967
http://dx.doi.org/10.1016/j.dib.2018.04.020
work_keys_str_mv AT khandegarvinita dataontreatmentofsewagewastewaterbyelectrocoagulationusingpunchedaluminumelectrodeandcharacterizationofgeneratedsludge
AT acharyasanigdha dataontreatmentofsewagewastewaterbyelectrocoagulationusingpunchedaluminumelectrodeandcharacterizationofgeneratedsludge
AT jainarinjayk dataontreatmentofsewagewastewaterbyelectrocoagulationusingpunchedaluminumelectrodeandcharacterizationofgeneratedsludge