Cargando…

Antigen-free control wells in an ELISA set-up for the determination of autoantibodies against G protein-coupled receptors—a requisite for correct data evaluation

First functional acting autoantibodies against G protein-coupled receptors such as the beta2-adrenoceptor in e.g. asthmatic patients have already been discovered in the early 1980s of the last century using assays that show their functional activity. Today, almost 40 years later, the measurement of...

Descripción completa

Detalles Bibliográficos
Autores principales: Haberland, Annekathrin, Müller, Johannes, Wallukat, Gerd, Wenzel, Katrin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6061717/
https://www.ncbi.nlm.nih.gov/pubmed/29947901
http://dx.doi.org/10.1007/s00216-018-1172-x
_version_ 1783342278641713152
author Haberland, Annekathrin
Müller, Johannes
Wallukat, Gerd
Wenzel, Katrin
author_facet Haberland, Annekathrin
Müller, Johannes
Wallukat, Gerd
Wenzel, Katrin
author_sort Haberland, Annekathrin
collection PubMed
description First functional acting autoantibodies against G protein-coupled receptors such as the beta2-adrenoceptor in e.g. asthmatic patients have already been discovered in the early 1980s of the last century using assays that show their functional activity. Today, almost 40 years later, the measurement of such autoantibodies is still a challenge. Bioassays able to show the functional activity of such autoantibodies against G protein-coupled receptors are still the ne plus ultra for their detection and also classification when additionally exploiting specific receptor blockers for the neutralisation of the effect. Bioassays based on living cells make specific demands on the laboratories and are, therefore not suitable for every routine laboratory. Routine diagnostics, therefore, ideally requires different assays based on e.g. solid-phase technology, such as enzyme-linked immunosorbent assay (ELISA) technology. Here, endeavours are going on, using either the exact epitopes of such autoantibodies, if known, for trapping the autoantibodies, or the complete receptor in biological or artificial membranes that are immobilised onto a plastic carrier (ELISA principle). Here, we question and discuss the outcome of such tests, especially, if no controls such as the non-coated plastic carrier or the corresponding receptor-free membrane coat is offered as control in parallel, in light of the manifold experiences already collected with even non-agonistic acting autoantibodies by Güven et al. (J Immunol Methods 403:26–36, 2014).
format Online
Article
Text
id pubmed-6061717
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-60617172018-08-09 Antigen-free control wells in an ELISA set-up for the determination of autoantibodies against G protein-coupled receptors—a requisite for correct data evaluation Haberland, Annekathrin Müller, Johannes Wallukat, Gerd Wenzel, Katrin Anal Bioanal Chem Feature Article First functional acting autoantibodies against G protein-coupled receptors such as the beta2-adrenoceptor in e.g. asthmatic patients have already been discovered in the early 1980s of the last century using assays that show their functional activity. Today, almost 40 years later, the measurement of such autoantibodies is still a challenge. Bioassays able to show the functional activity of such autoantibodies against G protein-coupled receptors are still the ne plus ultra for their detection and also classification when additionally exploiting specific receptor blockers for the neutralisation of the effect. Bioassays based on living cells make specific demands on the laboratories and are, therefore not suitable for every routine laboratory. Routine diagnostics, therefore, ideally requires different assays based on e.g. solid-phase technology, such as enzyme-linked immunosorbent assay (ELISA) technology. Here, endeavours are going on, using either the exact epitopes of such autoantibodies, if known, for trapping the autoantibodies, or the complete receptor in biological or artificial membranes that are immobilised onto a plastic carrier (ELISA principle). Here, we question and discuss the outcome of such tests, especially, if no controls such as the non-coated plastic carrier or the corresponding receptor-free membrane coat is offered as control in parallel, in light of the manifold experiences already collected with even non-agonistic acting autoantibodies by Güven et al. (J Immunol Methods 403:26–36, 2014). Springer Berlin Heidelberg 2018-06-11 2018 /pmc/articles/PMC6061717/ /pubmed/29947901 http://dx.doi.org/10.1007/s00216-018-1172-x Text en © The Author(s) 2018 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Feature Article
Haberland, Annekathrin
Müller, Johannes
Wallukat, Gerd
Wenzel, Katrin
Antigen-free control wells in an ELISA set-up for the determination of autoantibodies against G protein-coupled receptors—a requisite for correct data evaluation
title Antigen-free control wells in an ELISA set-up for the determination of autoantibodies against G protein-coupled receptors—a requisite for correct data evaluation
title_full Antigen-free control wells in an ELISA set-up for the determination of autoantibodies against G protein-coupled receptors—a requisite for correct data evaluation
title_fullStr Antigen-free control wells in an ELISA set-up for the determination of autoantibodies against G protein-coupled receptors—a requisite for correct data evaluation
title_full_unstemmed Antigen-free control wells in an ELISA set-up for the determination of autoantibodies against G protein-coupled receptors—a requisite for correct data evaluation
title_short Antigen-free control wells in an ELISA set-up for the determination of autoantibodies against G protein-coupled receptors—a requisite for correct data evaluation
title_sort antigen-free control wells in an elisa set-up for the determination of autoantibodies against g protein-coupled receptors—a requisite for correct data evaluation
topic Feature Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6061717/
https://www.ncbi.nlm.nih.gov/pubmed/29947901
http://dx.doi.org/10.1007/s00216-018-1172-x
work_keys_str_mv AT haberlandannekathrin antigenfreecontrolwellsinanelisasetupforthedeterminationofautoantibodiesagainstgproteincoupledreceptorsarequisiteforcorrectdataevaluation
AT mullerjohannes antigenfreecontrolwellsinanelisasetupforthedeterminationofautoantibodiesagainstgproteincoupledreceptorsarequisiteforcorrectdataevaluation
AT wallukatgerd antigenfreecontrolwellsinanelisasetupforthedeterminationofautoantibodiesagainstgproteincoupledreceptorsarequisiteforcorrectdataevaluation
AT wenzelkatrin antigenfreecontrolwellsinanelisasetupforthedeterminationofautoantibodiesagainstgproteincoupledreceptorsarequisiteforcorrectdataevaluation