Cargando…

Repeatability and reproducibility of retinal and choroidal thickness measurements in Diabetic Macular Edema using Swept-source Optical Coherence Tomography

PURPOSE: To evaluate the repeatability and reproducibility of retinal and choroidal thickness measured with Swept source Optical Coherence Tomography (SS-OCT) in eyes with Diabetic Macular Edema (DME). METHODS: 42 DME eyes were imaged using SS-OCT standard Macular scanning protocols. Retinal and cho...

Descripción completa

Detalles Bibliográficos
Autores principales: Sala-Puigdollers, Anna, Figueras-Roca, Marc, Hereu, Mireia, Hernández, Teresa, Morató, Montse, Adán, Alfredo, Zarranz-Ventura, Javier
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6062033/
https://www.ncbi.nlm.nih.gov/pubmed/30048478
http://dx.doi.org/10.1371/journal.pone.0200819
_version_ 1783342324452950016
author Sala-Puigdollers, Anna
Figueras-Roca, Marc
Hereu, Mireia
Hernández, Teresa
Morató, Montse
Adán, Alfredo
Zarranz-Ventura, Javier
author_facet Sala-Puigdollers, Anna
Figueras-Roca, Marc
Hereu, Mireia
Hernández, Teresa
Morató, Montse
Adán, Alfredo
Zarranz-Ventura, Javier
author_sort Sala-Puigdollers, Anna
collection PubMed
description PURPOSE: To evaluate the repeatability and reproducibility of retinal and choroidal thickness measured with Swept source Optical Coherence Tomography (SS-OCT) in eyes with Diabetic Macular Edema (DME). METHODS: 42 DME eyes were imaged using SS-OCT standard Macular scanning protocols. Retinal and choroidal thickness were measured in the Total macular circle (TMC) and foveal central subfield (FCS) using device-integrated specific software. The coefficient of repeatability (CR) and intraclass correlation coefficient (ICC) were determined as a measure of repeatability and relative reliability within graders. Reproducibility was assessed using Bland-Altman plots and 95% limits of agreement (LoA) were determined as a measure of interobserver variability. RESULTS: Intragrader CR of retinal and choroidal thickness were 8.37 and 12.20 microns for TMC and 22.24 and 32.40 microns for FCS, and intergrader 95% LoA were 7.37–8.69 and -27.2–27.71 microns for TMC and -34.21–41.93 and -30.46–24.84 for FCS, respectively. Retinal and choroidal thickness showed very good intraobserver reliability for both TMC and FCS (ICC 0.99, LoA 0.98–0.99 in all cases). Intraobserver and interobserver variability for retinal and choroidal thickness was not significantly different for TMC (p = 0.98 and p = 0.90, p = 0.98 and p = 0.91) or FCS (p = 0.97 and p = 0.85, p = 0.78 and p = 0.73), respectively. CONCLUSIONS: Retinal and choroidal thickness in DME eyes can be quantified with good reliability, repeatability and reproducibility using new OCT devices that incorporate swept source technology. The technical advantages of this technology may provide new insights in the understanding of the choroidal changes related with DME.
format Online
Article
Text
id pubmed-6062033
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-60620332018-08-03 Repeatability and reproducibility of retinal and choroidal thickness measurements in Diabetic Macular Edema using Swept-source Optical Coherence Tomography Sala-Puigdollers, Anna Figueras-Roca, Marc Hereu, Mireia Hernández, Teresa Morató, Montse Adán, Alfredo Zarranz-Ventura, Javier PLoS One Research Article PURPOSE: To evaluate the repeatability and reproducibility of retinal and choroidal thickness measured with Swept source Optical Coherence Tomography (SS-OCT) in eyes with Diabetic Macular Edema (DME). METHODS: 42 DME eyes were imaged using SS-OCT standard Macular scanning protocols. Retinal and choroidal thickness were measured in the Total macular circle (TMC) and foveal central subfield (FCS) using device-integrated specific software. The coefficient of repeatability (CR) and intraclass correlation coefficient (ICC) were determined as a measure of repeatability and relative reliability within graders. Reproducibility was assessed using Bland-Altman plots and 95% limits of agreement (LoA) were determined as a measure of interobserver variability. RESULTS: Intragrader CR of retinal and choroidal thickness were 8.37 and 12.20 microns for TMC and 22.24 and 32.40 microns for FCS, and intergrader 95% LoA were 7.37–8.69 and -27.2–27.71 microns for TMC and -34.21–41.93 and -30.46–24.84 for FCS, respectively. Retinal and choroidal thickness showed very good intraobserver reliability for both TMC and FCS (ICC 0.99, LoA 0.98–0.99 in all cases). Intraobserver and interobserver variability for retinal and choroidal thickness was not significantly different for TMC (p = 0.98 and p = 0.90, p = 0.98 and p = 0.91) or FCS (p = 0.97 and p = 0.85, p = 0.78 and p = 0.73), respectively. CONCLUSIONS: Retinal and choroidal thickness in DME eyes can be quantified with good reliability, repeatability and reproducibility using new OCT devices that incorporate swept source technology. The technical advantages of this technology may provide new insights in the understanding of the choroidal changes related with DME. Public Library of Science 2018-07-26 /pmc/articles/PMC6062033/ /pubmed/30048478 http://dx.doi.org/10.1371/journal.pone.0200819 Text en © 2018 Sala-Puigdollers et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Sala-Puigdollers, Anna
Figueras-Roca, Marc
Hereu, Mireia
Hernández, Teresa
Morató, Montse
Adán, Alfredo
Zarranz-Ventura, Javier
Repeatability and reproducibility of retinal and choroidal thickness measurements in Diabetic Macular Edema using Swept-source Optical Coherence Tomography
title Repeatability and reproducibility of retinal and choroidal thickness measurements in Diabetic Macular Edema using Swept-source Optical Coherence Tomography
title_full Repeatability and reproducibility of retinal and choroidal thickness measurements in Diabetic Macular Edema using Swept-source Optical Coherence Tomography
title_fullStr Repeatability and reproducibility of retinal and choroidal thickness measurements in Diabetic Macular Edema using Swept-source Optical Coherence Tomography
title_full_unstemmed Repeatability and reproducibility of retinal and choroidal thickness measurements in Diabetic Macular Edema using Swept-source Optical Coherence Tomography
title_short Repeatability and reproducibility of retinal and choroidal thickness measurements in Diabetic Macular Edema using Swept-source Optical Coherence Tomography
title_sort repeatability and reproducibility of retinal and choroidal thickness measurements in diabetic macular edema using swept-source optical coherence tomography
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6062033/
https://www.ncbi.nlm.nih.gov/pubmed/30048478
http://dx.doi.org/10.1371/journal.pone.0200819
work_keys_str_mv AT salapuigdollersanna repeatabilityandreproducibilityofretinalandchoroidalthicknessmeasurementsindiabeticmacularedemausingsweptsourceopticalcoherencetomography
AT figuerasrocamarc repeatabilityandreproducibilityofretinalandchoroidalthicknessmeasurementsindiabeticmacularedemausingsweptsourceopticalcoherencetomography
AT hereumireia repeatabilityandreproducibilityofretinalandchoroidalthicknessmeasurementsindiabeticmacularedemausingsweptsourceopticalcoherencetomography
AT hernandezteresa repeatabilityandreproducibilityofretinalandchoroidalthicknessmeasurementsindiabeticmacularedemausingsweptsourceopticalcoherencetomography
AT moratomontse repeatabilityandreproducibilityofretinalandchoroidalthicknessmeasurementsindiabeticmacularedemausingsweptsourceopticalcoherencetomography
AT adanalfredo repeatabilityandreproducibilityofretinalandchoroidalthicknessmeasurementsindiabeticmacularedemausingsweptsourceopticalcoherencetomography
AT zarranzventurajavier repeatabilityandreproducibilityofretinalandchoroidalthicknessmeasurementsindiabeticmacularedemausingsweptsourceopticalcoherencetomography