Sensitivity of Single-Molecule Array Assays for Detection of Clostridium difficile Toxins in Comparison to Conventional Laboratory Testing Algorithms

Guidelines recommend the use of an algorithm for the laboratory diagnosis of Clostridium difficile infection (CDI). Enzyme immunoassays (EIAs) detecting C. difficile toxins cannot be used as standalone tests due to suboptimal sensitivity, and molecular tests suffer from nonspecificity by detecting c...

Descripción completa

Detalles Bibliográficos
Autores principales: Banz, Alice, Lantz, Aude, Riou, Brigitte, Foussadier, Agnès, Miller, Mark, Davies, Kerrie, Wilcox, Mark
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Society for Microbiology 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6062787/
https://www.ncbi.nlm.nih.gov/pubmed/29898996
http://dx.doi.org/10.1128/JCM.00452-18
_version_ 1783342436679942144
author Banz, Alice
Lantz, Aude
Riou, Brigitte
Foussadier, Agnès
Miller, Mark
Davies, Kerrie
Wilcox, Mark
author_facet Banz, Alice
Lantz, Aude
Riou, Brigitte
Foussadier, Agnès
Miller, Mark
Davies, Kerrie
Wilcox, Mark
author_sort Banz, Alice
collection PubMed
description Guidelines recommend the use of an algorithm for the laboratory diagnosis of Clostridium difficile infection (CDI). Enzyme immunoassays (EIAs) detecting C. difficile toxins cannot be used as standalone tests due to suboptimal sensitivity, and molecular tests suffer from nonspecificity by detecting colonization. Sensitive immunoassays have recently been developed to improve and simplify CDI diagnosis. Assays detecting CD toxins have been developed using single-molecule array (SIMOA) technology. SIMOA performance was assessed relative to a laboratory case definition of CDI defined by positive glutamate dehydrogenase (GDH) screen and cell cytotoxicity neutralizing assay (CCNA). Samples were tested with SIMOA assays and a commercial toxin EIA to compare performance, with discrepancy resolution using a commercial nucleic acid-based test and a second cell cytotoxicity assay. The SIMOA toxin A and toxin B assays showed limits of detection of 0.6 and 2.9 pg/ml, respectively, and intra-assay coefficients of variation of less than 10%. The optimal clinical thresholds for the toxin A and toxin B assays were determined to be 22.1 and 18.8 pg/ml, respectively, with resultant sensitivities of 84.8 and 95.5%. In contrast, a high-performing EIA toxin test had a sensitivity of 71.2%. Thus, the SIMOA assays detected toxins in 24% more samples with laboratory-defined CDI than the high performing toxin EIA (95% [63/66] versus 71% [47/66]). This study shows that SIMOA C. difficile toxin assays have a higher sensitivity than currently available toxin EIA and have the potential to improve CDI diagnosis.
format Online
Article
Text
id pubmed-6062787
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher American Society for Microbiology
record_format MEDLINE/PubMed
spelling pubmed-60627872018-08-08 Sensitivity of Single-Molecule Array Assays for Detection of Clostridium difficile Toxins in Comparison to Conventional Laboratory Testing Algorithms Banz, Alice Lantz, Aude Riou, Brigitte Foussadier, Agnès Miller, Mark Davies, Kerrie Wilcox, Mark J Clin Microbiol Immunoassays Guidelines recommend the use of an algorithm for the laboratory diagnosis of Clostridium difficile infection (CDI). Enzyme immunoassays (EIAs) detecting C. difficile toxins cannot be used as standalone tests due to suboptimal sensitivity, and molecular tests suffer from nonspecificity by detecting colonization. Sensitive immunoassays have recently been developed to improve and simplify CDI diagnosis. Assays detecting CD toxins have been developed using single-molecule array (SIMOA) technology. SIMOA performance was assessed relative to a laboratory case definition of CDI defined by positive glutamate dehydrogenase (GDH) screen and cell cytotoxicity neutralizing assay (CCNA). Samples were tested with SIMOA assays and a commercial toxin EIA to compare performance, with discrepancy resolution using a commercial nucleic acid-based test and a second cell cytotoxicity assay. The SIMOA toxin A and toxin B assays showed limits of detection of 0.6 and 2.9 pg/ml, respectively, and intra-assay coefficients of variation of less than 10%. The optimal clinical thresholds for the toxin A and toxin B assays were determined to be 22.1 and 18.8 pg/ml, respectively, with resultant sensitivities of 84.8 and 95.5%. In contrast, a high-performing EIA toxin test had a sensitivity of 71.2%. Thus, the SIMOA assays detected toxins in 24% more samples with laboratory-defined CDI than the high performing toxin EIA (95% [63/66] versus 71% [47/66]). This study shows that SIMOA C. difficile toxin assays have a higher sensitivity than currently available toxin EIA and have the potential to improve CDI diagnosis. American Society for Microbiology 2018-07-26 /pmc/articles/PMC6062787/ /pubmed/29898996 http://dx.doi.org/10.1128/JCM.00452-18 Text en Copyright © 2018 Banz et al. https://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution 4.0 International license (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Immunoassays
Banz, Alice
Lantz, Aude
Riou, Brigitte
Foussadier, Agnès
Miller, Mark
Davies, Kerrie
Wilcox, Mark
Sensitivity of Single-Molecule Array Assays for Detection of Clostridium difficile Toxins in Comparison to Conventional Laboratory Testing Algorithms
title Sensitivity of Single-Molecule Array Assays for Detection of Clostridium difficile Toxins in Comparison to Conventional Laboratory Testing Algorithms
title_full Sensitivity of Single-Molecule Array Assays for Detection of Clostridium difficile Toxins in Comparison to Conventional Laboratory Testing Algorithms
title_fullStr Sensitivity of Single-Molecule Array Assays for Detection of Clostridium difficile Toxins in Comparison to Conventional Laboratory Testing Algorithms
title_full_unstemmed Sensitivity of Single-Molecule Array Assays for Detection of Clostridium difficile Toxins in Comparison to Conventional Laboratory Testing Algorithms
title_short Sensitivity of Single-Molecule Array Assays for Detection of Clostridium difficile Toxins in Comparison to Conventional Laboratory Testing Algorithms
title_sort sensitivity of single-molecule array assays for detection of clostridium difficile toxins in comparison to conventional laboratory testing algorithms
topic Immunoassays
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6062787/
https://www.ncbi.nlm.nih.gov/pubmed/29898996
http://dx.doi.org/10.1128/JCM.00452-18
work_keys_str_mv AT banzalice sensitivityofsinglemoleculearrayassaysfordetectionofclostridiumdifficiletoxinsincomparisontoconventionallaboratorytestingalgorithms
AT lantzaude sensitivityofsinglemoleculearrayassaysfordetectionofclostridiumdifficiletoxinsincomparisontoconventionallaboratorytestingalgorithms
AT rioubrigitte sensitivityofsinglemoleculearrayassaysfordetectionofclostridiumdifficiletoxinsincomparisontoconventionallaboratorytestingalgorithms
AT foussadieragnes sensitivityofsinglemoleculearrayassaysfordetectionofclostridiumdifficiletoxinsincomparisontoconventionallaboratorytestingalgorithms
AT millermark sensitivityofsinglemoleculearrayassaysfordetectionofclostridiumdifficiletoxinsincomparisontoconventionallaboratorytestingalgorithms
AT davieskerrie sensitivityofsinglemoleculearrayassaysfordetectionofclostridiumdifficiletoxinsincomparisontoconventionallaboratorytestingalgorithms
AT wilcoxmark sensitivityofsinglemoleculearrayassaysfordetectionofclostridiumdifficiletoxinsincomparisontoconventionallaboratorytestingalgorithms