Cargando…
Sensitivity of Single-Molecule Array Assays for Detection of Clostridium difficile Toxins in Comparison to Conventional Laboratory Testing Algorithms
Guidelines recommend the use of an algorithm for the laboratory diagnosis of Clostridium difficile infection (CDI). Enzyme immunoassays (EIAs) detecting C. difficile toxins cannot be used as standalone tests due to suboptimal sensitivity, and molecular tests suffer from nonspecificity by detecting c...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
American Society for Microbiology
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6062787/ https://www.ncbi.nlm.nih.gov/pubmed/29898996 http://dx.doi.org/10.1128/JCM.00452-18 |
_version_ | 1783342436679942144 |
---|---|
author | Banz, Alice Lantz, Aude Riou, Brigitte Foussadier, Agnès Miller, Mark Davies, Kerrie Wilcox, Mark |
author_facet | Banz, Alice Lantz, Aude Riou, Brigitte Foussadier, Agnès Miller, Mark Davies, Kerrie Wilcox, Mark |
author_sort | Banz, Alice |
collection | PubMed |
description | Guidelines recommend the use of an algorithm for the laboratory diagnosis of Clostridium difficile infection (CDI). Enzyme immunoassays (EIAs) detecting C. difficile toxins cannot be used as standalone tests due to suboptimal sensitivity, and molecular tests suffer from nonspecificity by detecting colonization. Sensitive immunoassays have recently been developed to improve and simplify CDI diagnosis. Assays detecting CD toxins have been developed using single-molecule array (SIMOA) technology. SIMOA performance was assessed relative to a laboratory case definition of CDI defined by positive glutamate dehydrogenase (GDH) screen and cell cytotoxicity neutralizing assay (CCNA). Samples were tested with SIMOA assays and a commercial toxin EIA to compare performance, with discrepancy resolution using a commercial nucleic acid-based test and a second cell cytotoxicity assay. The SIMOA toxin A and toxin B assays showed limits of detection of 0.6 and 2.9 pg/ml, respectively, and intra-assay coefficients of variation of less than 10%. The optimal clinical thresholds for the toxin A and toxin B assays were determined to be 22.1 and 18.8 pg/ml, respectively, with resultant sensitivities of 84.8 and 95.5%. In contrast, a high-performing EIA toxin test had a sensitivity of 71.2%. Thus, the SIMOA assays detected toxins in 24% more samples with laboratory-defined CDI than the high performing toxin EIA (95% [63/66] versus 71% [47/66]). This study shows that SIMOA C. difficile toxin assays have a higher sensitivity than currently available toxin EIA and have the potential to improve CDI diagnosis. |
format | Online Article Text |
id | pubmed-6062787 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | American Society for Microbiology |
record_format | MEDLINE/PubMed |
spelling | pubmed-60627872018-08-08 Sensitivity of Single-Molecule Array Assays for Detection of Clostridium difficile Toxins in Comparison to Conventional Laboratory Testing Algorithms Banz, Alice Lantz, Aude Riou, Brigitte Foussadier, Agnès Miller, Mark Davies, Kerrie Wilcox, Mark J Clin Microbiol Immunoassays Guidelines recommend the use of an algorithm for the laboratory diagnosis of Clostridium difficile infection (CDI). Enzyme immunoassays (EIAs) detecting C. difficile toxins cannot be used as standalone tests due to suboptimal sensitivity, and molecular tests suffer from nonspecificity by detecting colonization. Sensitive immunoassays have recently been developed to improve and simplify CDI diagnosis. Assays detecting CD toxins have been developed using single-molecule array (SIMOA) technology. SIMOA performance was assessed relative to a laboratory case definition of CDI defined by positive glutamate dehydrogenase (GDH) screen and cell cytotoxicity neutralizing assay (CCNA). Samples were tested with SIMOA assays and a commercial toxin EIA to compare performance, with discrepancy resolution using a commercial nucleic acid-based test and a second cell cytotoxicity assay. The SIMOA toxin A and toxin B assays showed limits of detection of 0.6 and 2.9 pg/ml, respectively, and intra-assay coefficients of variation of less than 10%. The optimal clinical thresholds for the toxin A and toxin B assays were determined to be 22.1 and 18.8 pg/ml, respectively, with resultant sensitivities of 84.8 and 95.5%. In contrast, a high-performing EIA toxin test had a sensitivity of 71.2%. Thus, the SIMOA assays detected toxins in 24% more samples with laboratory-defined CDI than the high performing toxin EIA (95% [63/66] versus 71% [47/66]). This study shows that SIMOA C. difficile toxin assays have a higher sensitivity than currently available toxin EIA and have the potential to improve CDI diagnosis. American Society for Microbiology 2018-07-26 /pmc/articles/PMC6062787/ /pubmed/29898996 http://dx.doi.org/10.1128/JCM.00452-18 Text en Copyright © 2018 Banz et al. https://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution 4.0 International license (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Immunoassays Banz, Alice Lantz, Aude Riou, Brigitte Foussadier, Agnès Miller, Mark Davies, Kerrie Wilcox, Mark Sensitivity of Single-Molecule Array Assays for Detection of Clostridium difficile Toxins in Comparison to Conventional Laboratory Testing Algorithms |
title | Sensitivity of Single-Molecule Array Assays for Detection of Clostridium difficile Toxins in Comparison to Conventional Laboratory Testing Algorithms |
title_full | Sensitivity of Single-Molecule Array Assays for Detection of Clostridium difficile Toxins in Comparison to Conventional Laboratory Testing Algorithms |
title_fullStr | Sensitivity of Single-Molecule Array Assays for Detection of Clostridium difficile Toxins in Comparison to Conventional Laboratory Testing Algorithms |
title_full_unstemmed | Sensitivity of Single-Molecule Array Assays for Detection of Clostridium difficile Toxins in Comparison to Conventional Laboratory Testing Algorithms |
title_short | Sensitivity of Single-Molecule Array Assays for Detection of Clostridium difficile Toxins in Comparison to Conventional Laboratory Testing Algorithms |
title_sort | sensitivity of single-molecule array assays for detection of clostridium difficile toxins in comparison to conventional laboratory testing algorithms |
topic | Immunoassays |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6062787/ https://www.ncbi.nlm.nih.gov/pubmed/29898996 http://dx.doi.org/10.1128/JCM.00452-18 |
work_keys_str_mv | AT banzalice sensitivityofsinglemoleculearrayassaysfordetectionofclostridiumdifficiletoxinsincomparisontoconventionallaboratorytestingalgorithms AT lantzaude sensitivityofsinglemoleculearrayassaysfordetectionofclostridiumdifficiletoxinsincomparisontoconventionallaboratorytestingalgorithms AT rioubrigitte sensitivityofsinglemoleculearrayassaysfordetectionofclostridiumdifficiletoxinsincomparisontoconventionallaboratorytestingalgorithms AT foussadieragnes sensitivityofsinglemoleculearrayassaysfordetectionofclostridiumdifficiletoxinsincomparisontoconventionallaboratorytestingalgorithms AT millermark sensitivityofsinglemoleculearrayassaysfordetectionofclostridiumdifficiletoxinsincomparisontoconventionallaboratorytestingalgorithms AT davieskerrie sensitivityofsinglemoleculearrayassaysfordetectionofclostridiumdifficiletoxinsincomparisontoconventionallaboratorytestingalgorithms AT wilcoxmark sensitivityofsinglemoleculearrayassaysfordetectionofclostridiumdifficiletoxinsincomparisontoconventionallaboratorytestingalgorithms |