Cargando…

Multicenter Diagnostic Accuracy Evaluation of the Luminex Aries Real-Time PCR Assay for Group B Streptococcus Detection in Lim Broth-Enriched Samples

The vertical transmission of group B Streptococcus (GBS) strains causing neonatal sepsis is one of the leading reasons for neonatal mortality worldwide. The gold standard for GBS detection is enriched culture with or without the aid of chromogenic agars. Given the high risk for morbidity and mortali...

Descripción completa

Detalles Bibliográficos
Autores principales: Hernandez, D. R., Wolk, D. M., Walker, K. L., Young, S., Dunn, R., Dunbar, S. A., Rao, A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Society for Microbiology 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6062795/
https://www.ncbi.nlm.nih.gov/pubmed/29848562
http://dx.doi.org/10.1128/JCM.01768-17
_version_ 1783342437227298816
author Hernandez, D. R.
Wolk, D. M.
Walker, K. L.
Young, S.
Dunn, R.
Dunbar, S. A.
Rao, A.
author_facet Hernandez, D. R.
Wolk, D. M.
Walker, K. L.
Young, S.
Dunn, R.
Dunbar, S. A.
Rao, A.
author_sort Hernandez, D. R.
collection PubMed
description The vertical transmission of group B Streptococcus (GBS) strains causing neonatal sepsis is one of the leading reasons for neonatal mortality worldwide. The gold standard for GBS detection is enriched culture with or without the aid of chromogenic agars. Given the high risk for morbidity and mortality in this population, high assay sensitivity is required to prevent the personal and economic costs of GBS disease. Nucleic acid amplification tests (NAATs) allow for objective determination of GBS colonization with a sensitivity and a specificity higher than those of traditional culture methods. In this study, we determined the analytical and clinical performance of the Aries GBS assay compared to those of the enrichment culture method, biochemical identification, and the NAATs used at the study sites. Remnant Lim broth samples were used to perform the Aries assay and reference testing. Upon first testing using enriched culture as the reference standard, the Aries GBS assay identified GBS with a 96.1% sensitivity (95% confidence interval [CI], 91.2 to 98.7%) and a 91.4% specificity (95% CI, 88.8 to 93.6%). The test performed with 100% positive agreement (95% CI, 83.2 to 100%) compared to the results of the BD Max GBS assay and 98.0% positive agreement (95% CI, 89.2 to 99.9%) compared to the results of the Cepheid Xpert GBS LB test. Repeatability and reproducibility were maintained in intra- and interlaboratory testing, regardless of the instrument, module, or user who performed the test. The Aries GBS assay can be set up in less than 5 min and produces results in 2 h. The easy setup, with minimal hands-on time, and high assay sensitivity and specificity make this a useful testing option for GBS screening in prepartum women.
format Online
Article
Text
id pubmed-6062795
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher American Society for Microbiology
record_format MEDLINE/PubMed
spelling pubmed-60627952018-08-08 Multicenter Diagnostic Accuracy Evaluation of the Luminex Aries Real-Time PCR Assay for Group B Streptococcus Detection in Lim Broth-Enriched Samples Hernandez, D. R. Wolk, D. M. Walker, K. L. Young, S. Dunn, R. Dunbar, S. A. Rao, A. J Clin Microbiol Bacteriology The vertical transmission of group B Streptococcus (GBS) strains causing neonatal sepsis is one of the leading reasons for neonatal mortality worldwide. The gold standard for GBS detection is enriched culture with or without the aid of chromogenic agars. Given the high risk for morbidity and mortality in this population, high assay sensitivity is required to prevent the personal and economic costs of GBS disease. Nucleic acid amplification tests (NAATs) allow for objective determination of GBS colonization with a sensitivity and a specificity higher than those of traditional culture methods. In this study, we determined the analytical and clinical performance of the Aries GBS assay compared to those of the enrichment culture method, biochemical identification, and the NAATs used at the study sites. Remnant Lim broth samples were used to perform the Aries assay and reference testing. Upon first testing using enriched culture as the reference standard, the Aries GBS assay identified GBS with a 96.1% sensitivity (95% confidence interval [CI], 91.2 to 98.7%) and a 91.4% specificity (95% CI, 88.8 to 93.6%). The test performed with 100% positive agreement (95% CI, 83.2 to 100%) compared to the results of the BD Max GBS assay and 98.0% positive agreement (95% CI, 89.2 to 99.9%) compared to the results of the Cepheid Xpert GBS LB test. Repeatability and reproducibility were maintained in intra- and interlaboratory testing, regardless of the instrument, module, or user who performed the test. The Aries GBS assay can be set up in less than 5 min and produces results in 2 h. The easy setup, with minimal hands-on time, and high assay sensitivity and specificity make this a useful testing option for GBS screening in prepartum women. American Society for Microbiology 2018-07-26 /pmc/articles/PMC6062795/ /pubmed/29848562 http://dx.doi.org/10.1128/JCM.01768-17 Text en Copyright © 2018 Hernandez et al. https://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution 4.0 International license (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Bacteriology
Hernandez, D. R.
Wolk, D. M.
Walker, K. L.
Young, S.
Dunn, R.
Dunbar, S. A.
Rao, A.
Multicenter Diagnostic Accuracy Evaluation of the Luminex Aries Real-Time PCR Assay for Group B Streptococcus Detection in Lim Broth-Enriched Samples
title Multicenter Diagnostic Accuracy Evaluation of the Luminex Aries Real-Time PCR Assay for Group B Streptococcus Detection in Lim Broth-Enriched Samples
title_full Multicenter Diagnostic Accuracy Evaluation of the Luminex Aries Real-Time PCR Assay for Group B Streptococcus Detection in Lim Broth-Enriched Samples
title_fullStr Multicenter Diagnostic Accuracy Evaluation of the Luminex Aries Real-Time PCR Assay for Group B Streptococcus Detection in Lim Broth-Enriched Samples
title_full_unstemmed Multicenter Diagnostic Accuracy Evaluation of the Luminex Aries Real-Time PCR Assay for Group B Streptococcus Detection in Lim Broth-Enriched Samples
title_short Multicenter Diagnostic Accuracy Evaluation of the Luminex Aries Real-Time PCR Assay for Group B Streptococcus Detection in Lim Broth-Enriched Samples
title_sort multicenter diagnostic accuracy evaluation of the luminex aries real-time pcr assay for group b streptococcus detection in lim broth-enriched samples
topic Bacteriology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6062795/
https://www.ncbi.nlm.nih.gov/pubmed/29848562
http://dx.doi.org/10.1128/JCM.01768-17
work_keys_str_mv AT hernandezdr multicenterdiagnosticaccuracyevaluationoftheluminexariesrealtimepcrassayforgroupbstreptococcusdetectioninlimbrothenrichedsamples
AT wolkdm multicenterdiagnosticaccuracyevaluationoftheluminexariesrealtimepcrassayforgroupbstreptococcusdetectioninlimbrothenrichedsamples
AT walkerkl multicenterdiagnosticaccuracyevaluationoftheluminexariesrealtimepcrassayforgroupbstreptococcusdetectioninlimbrothenrichedsamples
AT youngs multicenterdiagnosticaccuracyevaluationoftheluminexariesrealtimepcrassayforgroupbstreptococcusdetectioninlimbrothenrichedsamples
AT dunnr multicenterdiagnosticaccuracyevaluationoftheluminexariesrealtimepcrassayforgroupbstreptococcusdetectioninlimbrothenrichedsamples
AT dunbarsa multicenterdiagnosticaccuracyevaluationoftheluminexariesrealtimepcrassayforgroupbstreptococcusdetectioninlimbrothenrichedsamples
AT raoa multicenterdiagnosticaccuracyevaluationoftheluminexariesrealtimepcrassayforgroupbstreptococcusdetectioninlimbrothenrichedsamples