Cargando…

Contact Pathway Function During Human Whole Blood Clotting on Procoagulant Surfaces

Microfluidic thrombosis assays allow the control of anticoagulation, hemodynamics, pharmacology, and procoagulant surfaces containing collagen ± tissue factor (TF). With corn trypsin inhibitor (CTI) ranging from low (1–4 μg/mL) to high levels (40–60 μg/mL), the function of Factor XIIa (FXIIa) can be...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhu, Shu, Herbig, Bradley A., Yu, Xinren, Chen, Jason, Diamond, Scott L.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6064720/
https://www.ncbi.nlm.nih.gov/pubmed/30083534
http://dx.doi.org/10.3389/fmed.2018.00209
_version_ 1783342741115109376
author Zhu, Shu
Herbig, Bradley A.
Yu, Xinren
Chen, Jason
Diamond, Scott L.
author_facet Zhu, Shu
Herbig, Bradley A.
Yu, Xinren
Chen, Jason
Diamond, Scott L.
author_sort Zhu, Shu
collection PubMed
description Microfluidic thrombosis assays allow the control of anticoagulation, hemodynamics, pharmacology, and procoagulant surfaces containing collagen ± tissue factor (TF). With corn trypsin inhibitor (CTI) ranging from low (1–4 μg/mL) to high levels (40–60 μg/mL), the function of Factor XIIa (FXIIa) can be modulated in the presence of low or high surface TF. With high CTI and no collagen/TF in the assay, no thrombin is generated during 15-min microfluidic perfusion. At low CTI (no TF), the generation of FXIa leads to fibrin polymerization at ~300 s after the initiation of flow over collagen, an onset time shortened at zero CTI and prolonged at high CTI. The engagement of FXIa was difficult to observe for clotting on high TF surfaces due to the dominance of the extrinsic pathway. Low TF surfaces allowed observable crosstalk between extrinsic pathway generation of thrombin and thrombin-mediated activation of FXIa, a feedback detected at >5 min and attenuated with polyphosphate inhibitor. From thrombin-antithrombin immunoassay of the effluent of blood flowing over collagen/TF, the majority of thrombin was found captured on intrathrombus fibrin. Additionally, extreme shear rates (>10,000 s(−1)) can generate massive von Willebrand Factor fibers that capture FXIIa and FXIa to drive fibrin generation, an event that facilitates VWF fiber dissolution under fibrinolytic conditions. Finally, we found that occlusive sterile thrombi subjected to pressure drops >70 mm-Hg/mm-clots have interstitial stresses sufficient to drive NETosis. These microfluidic studies highlight the interaction of contact pathway factors with the extrinsic pathway, platelet polyphosphate, VWF fibers, and potentially shear-induced NETs.
format Online
Article
Text
id pubmed-6064720
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-60647202018-08-06 Contact Pathway Function During Human Whole Blood Clotting on Procoagulant Surfaces Zhu, Shu Herbig, Bradley A. Yu, Xinren Chen, Jason Diamond, Scott L. Front Med (Lausanne) Medicine Microfluidic thrombosis assays allow the control of anticoagulation, hemodynamics, pharmacology, and procoagulant surfaces containing collagen ± tissue factor (TF). With corn trypsin inhibitor (CTI) ranging from low (1–4 μg/mL) to high levels (40–60 μg/mL), the function of Factor XIIa (FXIIa) can be modulated in the presence of low or high surface TF. With high CTI and no collagen/TF in the assay, no thrombin is generated during 15-min microfluidic perfusion. At low CTI (no TF), the generation of FXIa leads to fibrin polymerization at ~300 s after the initiation of flow over collagen, an onset time shortened at zero CTI and prolonged at high CTI. The engagement of FXIa was difficult to observe for clotting on high TF surfaces due to the dominance of the extrinsic pathway. Low TF surfaces allowed observable crosstalk between extrinsic pathway generation of thrombin and thrombin-mediated activation of FXIa, a feedback detected at >5 min and attenuated with polyphosphate inhibitor. From thrombin-antithrombin immunoassay of the effluent of blood flowing over collagen/TF, the majority of thrombin was found captured on intrathrombus fibrin. Additionally, extreme shear rates (>10,000 s(−1)) can generate massive von Willebrand Factor fibers that capture FXIIa and FXIa to drive fibrin generation, an event that facilitates VWF fiber dissolution under fibrinolytic conditions. Finally, we found that occlusive sterile thrombi subjected to pressure drops >70 mm-Hg/mm-clots have interstitial stresses sufficient to drive NETosis. These microfluidic studies highlight the interaction of contact pathway factors with the extrinsic pathway, platelet polyphosphate, VWF fibers, and potentially shear-induced NETs. Frontiers Media S.A. 2018-07-23 /pmc/articles/PMC6064720/ /pubmed/30083534 http://dx.doi.org/10.3389/fmed.2018.00209 Text en Copyright © 2018 Zhu, Herbig, Yu, Chen and Diamond. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Medicine
Zhu, Shu
Herbig, Bradley A.
Yu, Xinren
Chen, Jason
Diamond, Scott L.
Contact Pathway Function During Human Whole Blood Clotting on Procoagulant Surfaces
title Contact Pathway Function During Human Whole Blood Clotting on Procoagulant Surfaces
title_full Contact Pathway Function During Human Whole Blood Clotting on Procoagulant Surfaces
title_fullStr Contact Pathway Function During Human Whole Blood Clotting on Procoagulant Surfaces
title_full_unstemmed Contact Pathway Function During Human Whole Blood Clotting on Procoagulant Surfaces
title_short Contact Pathway Function During Human Whole Blood Clotting on Procoagulant Surfaces
title_sort contact pathway function during human whole blood clotting on procoagulant surfaces
topic Medicine
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6064720/
https://www.ncbi.nlm.nih.gov/pubmed/30083534
http://dx.doi.org/10.3389/fmed.2018.00209
work_keys_str_mv AT zhushu contactpathwayfunctionduringhumanwholebloodclottingonprocoagulantsurfaces
AT herbigbradleya contactpathwayfunctionduringhumanwholebloodclottingonprocoagulantsurfaces
AT yuxinren contactpathwayfunctionduringhumanwholebloodclottingonprocoagulantsurfaces
AT chenjason contactpathwayfunctionduringhumanwholebloodclottingonprocoagulantsurfaces
AT diamondscottl contactpathwayfunctionduringhumanwholebloodclottingonprocoagulantsurfaces