Cargando…

Evaluation of radiofrequency electronic system in intraoperative monitoring of surgical textiles

OBJECTIVE: To test performance of SurgiSafe(®), a radiofrequency electronic device to detect surgical textiles during operations as compared to manual counting. METHODS: Surgical sponges with radiofrequency TAGs were placed in the abdominal cavity of a pig submitted to laparotomy, in randomly distri...

Descripción completa

Detalles Bibliográficos
Autores principales: Antonio, Adriana Marco, Vieira, Carlos Andre Pereira
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Instituto Israelita de Ensino e Pesquisa Albert Einstein 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6066152/
https://www.ncbi.nlm.nih.gov/pubmed/29694622
http://dx.doi.org/10.1590/S1679-45082018AO3997
_version_ 1783342927197503488
author Antonio, Adriana Marco
Vieira, Carlos Andre Pereira
author_facet Antonio, Adriana Marco
Vieira, Carlos Andre Pereira
author_sort Antonio, Adriana Marco
collection PubMed
description OBJECTIVE: To test performance of SurgiSafe(®), a radiofrequency electronic device to detect surgical textiles during operations as compared to manual counting. METHODS: Surgical sponges with radiofrequency TAGs were placed in the abdominal cavity of a pig submitted to laparotomy, in randomly distributed sites. The TAGs were counted manually and also using SurgiSafe(®). Positive and negative predictive values, sensitivity, specificity and time required for counting were analyzed for both methods. RESULTS: Through the analysis of 35 surgical cycles, SurgiSafe(®) immediately identified all sponges, with specificity, sensitivity, positive and negative predictive values of 100%. Although not statistically significant, the manual count had sensitivity of 99.72% and specificity of 99.90%. CONCLUSION: SurgiSafe(®) proved to be an effective device to identify surgical sponges in vivo, in real time; and its use as an adjuvant to manual counting is very helpful to increase patient's safety.
format Online
Article
Text
id pubmed-6066152
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Instituto Israelita de Ensino e Pesquisa Albert Einstein
record_format MEDLINE/PubMed
spelling pubmed-60661522018-10-26 Evaluation of radiofrequency electronic system in intraoperative monitoring of surgical textiles Antonio, Adriana Marco Vieira, Carlos Andre Pereira Einstein (Sao Paulo) Original Article OBJECTIVE: To test performance of SurgiSafe(®), a radiofrequency electronic device to detect surgical textiles during operations as compared to manual counting. METHODS: Surgical sponges with radiofrequency TAGs were placed in the abdominal cavity of a pig submitted to laparotomy, in randomly distributed sites. The TAGs were counted manually and also using SurgiSafe(®). Positive and negative predictive values, sensitivity, specificity and time required for counting were analyzed for both methods. RESULTS: Through the analysis of 35 surgical cycles, SurgiSafe(®) immediately identified all sponges, with specificity, sensitivity, positive and negative predictive values of 100%. Although not statistically significant, the manual count had sensitivity of 99.72% and specificity of 99.90%. CONCLUSION: SurgiSafe(®) proved to be an effective device to identify surgical sponges in vivo, in real time; and its use as an adjuvant to manual counting is very helpful to increase patient's safety. Instituto Israelita de Ensino e Pesquisa Albert Einstein 2018-04-19 /pmc/articles/PMC6066152/ /pubmed/29694622 http://dx.doi.org/10.1590/S1679-45082018AO3997 Text en https://creativecommons.org/licenses/by/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License, which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Antonio, Adriana Marco
Vieira, Carlos Andre Pereira
Evaluation of radiofrequency electronic system in intraoperative monitoring of surgical textiles
title Evaluation of radiofrequency electronic system in intraoperative monitoring of surgical textiles
title_full Evaluation of radiofrequency electronic system in intraoperative monitoring of surgical textiles
title_fullStr Evaluation of radiofrequency electronic system in intraoperative monitoring of surgical textiles
title_full_unstemmed Evaluation of radiofrequency electronic system in intraoperative monitoring of surgical textiles
title_short Evaluation of radiofrequency electronic system in intraoperative monitoring of surgical textiles
title_sort evaluation of radiofrequency electronic system in intraoperative monitoring of surgical textiles
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6066152/
https://www.ncbi.nlm.nih.gov/pubmed/29694622
http://dx.doi.org/10.1590/S1679-45082018AO3997
work_keys_str_mv AT antonioadrianamarco evaluationofradiofrequencyelectronicsysteminintraoperativemonitoringofsurgicaltextiles
AT vieiracarlosandrepereira evaluationofradiofrequencyelectronicsysteminintraoperativemonitoringofsurgicaltextiles