Migration of all-polyethylene compared with metal-backed tibial components in cemented total knee arthroplasty: A randomized controlled trial

Background and purpose — With a rapidly increasing population in need of total knee arthroplasty (TKA), there is renewed interest in cost-saving all-polyethylene designs. Differences between metal-backed and all-polyethylene designs in initial component migration assessed by radiostereometric analys...

Descripción completa

Detalles Bibliográficos
Autores principales: Van Hamersveld, Koen T, Marang-Van De Mheen, Perla J, Nelissen, Rob G H H, Toksvig-Larsen, Sören
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Taylor & Francis 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6066763/
https://www.ncbi.nlm.nih.gov/pubmed/29714073
http://dx.doi.org/10.1080/17453674.2018.1464317
_version_ 1783343026857312256
author Van Hamersveld, Koen T
Marang-Van De Mheen, Perla J
Nelissen, Rob G H H
Toksvig-Larsen, Sören
author_facet Van Hamersveld, Koen T
Marang-Van De Mheen, Perla J
Nelissen, Rob G H H
Toksvig-Larsen, Sören
author_sort Van Hamersveld, Koen T
collection PubMed
description Background and purpose — With a rapidly increasing population in need of total knee arthroplasty (TKA), there is renewed interest in cost-saving all-polyethylene designs. Differences between metal-backed and all-polyethylene designs in initial component migration assessed by radiostereometric analysis (RSA), a proven predictor for late aseptic loosening, have been scantily reported. The purpose of this study was to compare implant migration and clinical outcomes of all-polyethylene tibial components versus metal-backed trays of similar geometrical shape. Patients and methods — In this randomized controlled trial, 59 patients received a cemented Triathlon condylar-stabilizing implant (Stryker, Mahwah, NJ, USA) with either an all-polyethylene (n = 29) or a metal-backed tibial component (n = 30). RSA measurements and clinical scores (the Knee Society Score, Forgotten Joint Score, and Knee Osteoarthritis and Injury Outcome Score) were evaluated at baseline and postoperatively at 3, 12, and 24 months. A linear mixed-effects model was used to analyze the repeated measurements. Results — A statistically significant difference in mean migration after 2 years was found in favor of the all-polyethylene group, with a mean maximum total point motion of 0.61 mm (95% CI 0.49–0.74) versus 0.81 mm (95% CI 0.68–0.96) for the cemented group (p = 0.03). However, this difference was smaller and not statistically significant after post hoc adjustment for surgeon effect. Both groups showed comparable improvements on all clinical outcome scores over time. Interpretation — The Triathlon all-polyethylene tibial component showed less migration, suggesting a lower risk of late loosening as compared with its metal-backed counterpart. However, the found surgeon effect warrants further investigation.
format Online
Article
Text
id pubmed-6066763
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Taylor & Francis
record_format MEDLINE/PubMed
spelling pubmed-60667632018-08-06 Migration of all-polyethylene compared with metal-backed tibial components in cemented total knee arthroplasty: A randomized controlled trial Van Hamersveld, Koen T Marang-Van De Mheen, Perla J Nelissen, Rob G H H Toksvig-Larsen, Sören Acta Orthop Article Background and purpose — With a rapidly increasing population in need of total knee arthroplasty (TKA), there is renewed interest in cost-saving all-polyethylene designs. Differences between metal-backed and all-polyethylene designs in initial component migration assessed by radiostereometric analysis (RSA), a proven predictor for late aseptic loosening, have been scantily reported. The purpose of this study was to compare implant migration and clinical outcomes of all-polyethylene tibial components versus metal-backed trays of similar geometrical shape. Patients and methods — In this randomized controlled trial, 59 patients received a cemented Triathlon condylar-stabilizing implant (Stryker, Mahwah, NJ, USA) with either an all-polyethylene (n = 29) or a metal-backed tibial component (n = 30). RSA measurements and clinical scores (the Knee Society Score, Forgotten Joint Score, and Knee Osteoarthritis and Injury Outcome Score) were evaluated at baseline and postoperatively at 3, 12, and 24 months. A linear mixed-effects model was used to analyze the repeated measurements. Results — A statistically significant difference in mean migration after 2 years was found in favor of the all-polyethylene group, with a mean maximum total point motion of 0.61 mm (95% CI 0.49–0.74) versus 0.81 mm (95% CI 0.68–0.96) for the cemented group (p = 0.03). However, this difference was smaller and not statistically significant after post hoc adjustment for surgeon effect. Both groups showed comparable improvements on all clinical outcome scores over time. Interpretation — The Triathlon all-polyethylene tibial component showed less migration, suggesting a lower risk of late loosening as compared with its metal-backed counterpart. However, the found surgeon effect warrants further investigation. Taylor & Francis 2018-07-30 2018-05-01 /pmc/articles/PMC6066763/ /pubmed/29714073 http://dx.doi.org/10.1080/17453674.2018.1464317 Text en © 2018 The Author(s). Published by Taylor & Francis on behalf of the Nordic Orthopedic Federation. https://creativecommons.org/licenses/by/4.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution-Non-Commercial License (https://creativecommons.org/licenses/by/4.0)
spellingShingle Article
Van Hamersveld, Koen T
Marang-Van De Mheen, Perla J
Nelissen, Rob G H H
Toksvig-Larsen, Sören
Migration of all-polyethylene compared with metal-backed tibial components in cemented total knee arthroplasty: A randomized controlled trial
title Migration of all-polyethylene compared with metal-backed tibial components in cemented total knee arthroplasty: A randomized controlled trial
title_full Migration of all-polyethylene compared with metal-backed tibial components in cemented total knee arthroplasty: A randomized controlled trial
title_fullStr Migration of all-polyethylene compared with metal-backed tibial components in cemented total knee arthroplasty: A randomized controlled trial
title_full_unstemmed Migration of all-polyethylene compared with metal-backed tibial components in cemented total knee arthroplasty: A randomized controlled trial
title_short Migration of all-polyethylene compared with metal-backed tibial components in cemented total knee arthroplasty: A randomized controlled trial
title_sort migration of all-polyethylene compared with metal-backed tibial components in cemented total knee arthroplasty: a randomized controlled trial
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6066763/
https://www.ncbi.nlm.nih.gov/pubmed/29714073
http://dx.doi.org/10.1080/17453674.2018.1464317
work_keys_str_mv AT vanhamersveldkoent migrationofallpolyethylenecomparedwithmetalbackedtibialcomponentsincementedtotalkneearthroplastyarandomizedcontrolledtrial
AT marangvandemheenperlaj migrationofallpolyethylenecomparedwithmetalbackedtibialcomponentsincementedtotalkneearthroplastyarandomizedcontrolledtrial
AT nelissenrobghh migrationofallpolyethylenecomparedwithmetalbackedtibialcomponentsincementedtotalkneearthroplastyarandomizedcontrolledtrial
AT toksviglarsensoren migrationofallpolyethylenecomparedwithmetalbackedtibialcomponentsincementedtotalkneearthroplastyarandomizedcontrolledtrial