Diagnostic accuracy of a digital fundus photographic system for detection of retinopathy of prematurity requiring treatment (ROP-RT)

OBJECTIVES: To evaluate the diagnostic accuracy of a digital fundus photographic system that consists of taking fundus photographs by a trained technician using a RetCam(®) shuttle and interpreting fundus images by an expert to detect Retinotapthy of Prematurity requiring treatment (ROP-RT) which de...

Descripción completa

Detalles Bibliográficos
Autores principales: Wongwai, Phanthipha, Suwannaraj, Sirinya, Asawaphureekorn, Somkiat
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6067727/
https://www.ncbi.nlm.nih.gov/pubmed/30063746
http://dx.doi.org/10.1371/journal.pone.0201544
_version_ 1783343158760833024
author Wongwai, Phanthipha
Suwannaraj, Sirinya
Asawaphureekorn, Somkiat
author_facet Wongwai, Phanthipha
Suwannaraj, Sirinya
Asawaphureekorn, Somkiat
author_sort Wongwai, Phanthipha
collection PubMed
description OBJECTIVES: To evaluate the diagnostic accuracy of a digital fundus photographic system that consists of taking fundus photographs by a trained technician using a RetCam(®) shuttle and interpreting fundus images by an expert to detect Retinotapthy of Prematurity requiring treatment (ROP-RT) which defined as type I ROP according to the Early Treatment for ROP study (ETROP). MATERIALS AND METHODS: One hundred infants were examined by (1) an expert ophthalmologist experienced in ROP care using indirect ophthalmoscopy; (2) digital wide-field imaging by a trained technician using a RetCam(®) shuttle and images were sent remotely for interpretation by two ophthalmologists experienced in ROP care (Reader A, and Reader B); and (3) local ophthalmologists using indirect ophthalmoscopy. The diagnostic acurracy consisting of sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), positive likelihood ratio (LR+), and negative likelihood ratio (LR-) were calculated. Agreement between all examiners and readers were evaluated. RESULTS: A total of 100 infants (mean gestational age 31.1 weeks, mean birth weight 1,511.1 grams) participated in the study. Nine infants were classified as ROP-RT. Reader A and B had very good agreement in detection of ROP- RT (Kappa 1.00, 95% CI 1.00, 1.00). For reader A, diagnostic performance parameters (95% confidence intervals) for detecting ROP-RT were; sensitivity 100.0% (66.4, 100.0), specificity 97.8% (92.1, 99.7), PPV 81.8% (48.2, 97.7), NPV 100.0% (95.8, 100.0), LR+ 44.5 (11.3, 175.2), and LR- 0.1 (0.0, 0.8). For reader B these were; sensitivity 100.0% (66.4, 100.0), specificity 95.6% (89.0, 98.8), PPV 69.2% (38.6, 90.9), NPV 100.0% (95.8, 100.0), LR+ 22.5 (8.6, 58.6), LR- 0.1 (0.0, 0.8). No adverse events were reported. CONCLUSIONS: Diagnosis of ROP-RT from RetCam(®) images taken by trained technicians and evaluated remotely by an expert ophthalmologist had good diagnostic accuracy for screening purposes.
format Online
Article
Text
id pubmed-6067727
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-60677272018-08-10 Diagnostic accuracy of a digital fundus photographic system for detection of retinopathy of prematurity requiring treatment (ROP-RT) Wongwai, Phanthipha Suwannaraj, Sirinya Asawaphureekorn, Somkiat PLoS One Research Article OBJECTIVES: To evaluate the diagnostic accuracy of a digital fundus photographic system that consists of taking fundus photographs by a trained technician using a RetCam(®) shuttle and interpreting fundus images by an expert to detect Retinotapthy of Prematurity requiring treatment (ROP-RT) which defined as type I ROP according to the Early Treatment for ROP study (ETROP). MATERIALS AND METHODS: One hundred infants were examined by (1) an expert ophthalmologist experienced in ROP care using indirect ophthalmoscopy; (2) digital wide-field imaging by a trained technician using a RetCam(®) shuttle and images were sent remotely for interpretation by two ophthalmologists experienced in ROP care (Reader A, and Reader B); and (3) local ophthalmologists using indirect ophthalmoscopy. The diagnostic acurracy consisting of sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), positive likelihood ratio (LR+), and negative likelihood ratio (LR-) were calculated. Agreement between all examiners and readers were evaluated. RESULTS: A total of 100 infants (mean gestational age 31.1 weeks, mean birth weight 1,511.1 grams) participated in the study. Nine infants were classified as ROP-RT. Reader A and B had very good agreement in detection of ROP- RT (Kappa 1.00, 95% CI 1.00, 1.00). For reader A, diagnostic performance parameters (95% confidence intervals) for detecting ROP-RT were; sensitivity 100.0% (66.4, 100.0), specificity 97.8% (92.1, 99.7), PPV 81.8% (48.2, 97.7), NPV 100.0% (95.8, 100.0), LR+ 44.5 (11.3, 175.2), and LR- 0.1 (0.0, 0.8). For reader B these were; sensitivity 100.0% (66.4, 100.0), specificity 95.6% (89.0, 98.8), PPV 69.2% (38.6, 90.9), NPV 100.0% (95.8, 100.0), LR+ 22.5 (8.6, 58.6), LR- 0.1 (0.0, 0.8). No adverse events were reported. CONCLUSIONS: Diagnosis of ROP-RT from RetCam(®) images taken by trained technicians and evaluated remotely by an expert ophthalmologist had good diagnostic accuracy for screening purposes. Public Library of Science 2018-07-31 /pmc/articles/PMC6067727/ /pubmed/30063746 http://dx.doi.org/10.1371/journal.pone.0201544 Text en © 2018 Wongwai et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Wongwai, Phanthipha
Suwannaraj, Sirinya
Asawaphureekorn, Somkiat
Diagnostic accuracy of a digital fundus photographic system for detection of retinopathy of prematurity requiring treatment (ROP-RT)
title Diagnostic accuracy of a digital fundus photographic system for detection of retinopathy of prematurity requiring treatment (ROP-RT)
title_full Diagnostic accuracy of a digital fundus photographic system for detection of retinopathy of prematurity requiring treatment (ROP-RT)
title_fullStr Diagnostic accuracy of a digital fundus photographic system for detection of retinopathy of prematurity requiring treatment (ROP-RT)
title_full_unstemmed Diagnostic accuracy of a digital fundus photographic system for detection of retinopathy of prematurity requiring treatment (ROP-RT)
title_short Diagnostic accuracy of a digital fundus photographic system for detection of retinopathy of prematurity requiring treatment (ROP-RT)
title_sort diagnostic accuracy of a digital fundus photographic system for detection of retinopathy of prematurity requiring treatment (rop-rt)
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6067727/
https://www.ncbi.nlm.nih.gov/pubmed/30063746
http://dx.doi.org/10.1371/journal.pone.0201544
work_keys_str_mv AT wongwaiphanthipha diagnosticaccuracyofadigitalfundusphotographicsystemfordetectionofretinopathyofprematurityrequiringtreatmentroprt
AT suwannarajsirinya diagnosticaccuracyofadigitalfundusphotographicsystemfordetectionofretinopathyofprematurityrequiringtreatmentroprt
AT asawaphureekornsomkiat diagnosticaccuracyofadigitalfundusphotographicsystemfordetectionofretinopathyofprematurityrequiringtreatmentroprt