ED-FNN: A New Deep Learning Algorithm to Detect Percentage of the Gait Cycle for Powered Prostheses

Throughout the last decade, a whole new generation of powered transtibial prostheses and exoskeletons has been developed. However, these technologies are limited by a gait phase detection which controls the wearable device as a function of the activities of the wearer. Consequently, gait phase detec...

Descripción completa

Detalles Bibliográficos
Autores principales: Vu, Huong Thi Thu, Gomez, Felipe, Cherelle, Pierre, Lefeber, Dirk, Nowé, Ann, Vanderborght, Bram
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6068484/
https://www.ncbi.nlm.nih.gov/pubmed/30041421
http://dx.doi.org/10.3390/s18072389
_version_ 1783343279324004352
author Vu, Huong Thi Thu
Gomez, Felipe
Cherelle, Pierre
Lefeber, Dirk
Nowé, Ann
Vanderborght, Bram
author_facet Vu, Huong Thi Thu
Gomez, Felipe
Cherelle, Pierre
Lefeber, Dirk
Nowé, Ann
Vanderborght, Bram
author_sort Vu, Huong Thi Thu
collection PubMed
description Throughout the last decade, a whole new generation of powered transtibial prostheses and exoskeletons has been developed. However, these technologies are limited by a gait phase detection which controls the wearable device as a function of the activities of the wearer. Consequently, gait phase detection is considered to be of great importance, as achieving high detection accuracy will produce a more precise, stable, and safe rehabilitation device. In this paper, we propose a novel gait percent detection algorithm that can predict a full gait cycle discretised within a 1% interval. We called this algorithm an exponentially delayed fully connected neural network (ED-FNN). A dataset was obtained from seven healthy subjects that performed daily walking activities on the flat ground and a 15-degree slope. The signals were taken from only one inertial measurement unit (IMU) attached to the lower shank. The dataset was divided into training and validation datasets for every subject, and the mean square error (MSE) error between the model prediction and the real percentage of the gait was computed. An average MSE of 0.00522 was obtained for every subject in both training and validation sets, and an average MSE of 0.006 for the training set and 0.0116 for the validation set was obtained when combining all subjects’ signals together. Although our experiments were conducted in an offline setting, due to the forecasting capabilities of the ED-FNN, our system provides an opportunity to eliminate detection delays for real-time applications.
format Online
Article
Text
id pubmed-6068484
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-60684842018-08-07 ED-FNN: A New Deep Learning Algorithm to Detect Percentage of the Gait Cycle for Powered Prostheses Vu, Huong Thi Thu Gomez, Felipe Cherelle, Pierre Lefeber, Dirk Nowé, Ann Vanderborght, Bram Sensors (Basel) Article Throughout the last decade, a whole new generation of powered transtibial prostheses and exoskeletons has been developed. However, these technologies are limited by a gait phase detection which controls the wearable device as a function of the activities of the wearer. Consequently, gait phase detection is considered to be of great importance, as achieving high detection accuracy will produce a more precise, stable, and safe rehabilitation device. In this paper, we propose a novel gait percent detection algorithm that can predict a full gait cycle discretised within a 1% interval. We called this algorithm an exponentially delayed fully connected neural network (ED-FNN). A dataset was obtained from seven healthy subjects that performed daily walking activities on the flat ground and a 15-degree slope. The signals were taken from only one inertial measurement unit (IMU) attached to the lower shank. The dataset was divided into training and validation datasets for every subject, and the mean square error (MSE) error between the model prediction and the real percentage of the gait was computed. An average MSE of 0.00522 was obtained for every subject in both training and validation sets, and an average MSE of 0.006 for the training set and 0.0116 for the validation set was obtained when combining all subjects’ signals together. Although our experiments were conducted in an offline setting, due to the forecasting capabilities of the ED-FNN, our system provides an opportunity to eliminate detection delays for real-time applications. MDPI 2018-07-23 /pmc/articles/PMC6068484/ /pubmed/30041421 http://dx.doi.org/10.3390/s18072389 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Vu, Huong Thi Thu
Gomez, Felipe
Cherelle, Pierre
Lefeber, Dirk
Nowé, Ann
Vanderborght, Bram
ED-FNN: A New Deep Learning Algorithm to Detect Percentage of the Gait Cycle for Powered Prostheses
title ED-FNN: A New Deep Learning Algorithm to Detect Percentage of the Gait Cycle for Powered Prostheses
title_full ED-FNN: A New Deep Learning Algorithm to Detect Percentage of the Gait Cycle for Powered Prostheses
title_fullStr ED-FNN: A New Deep Learning Algorithm to Detect Percentage of the Gait Cycle for Powered Prostheses
title_full_unstemmed ED-FNN: A New Deep Learning Algorithm to Detect Percentage of the Gait Cycle for Powered Prostheses
title_short ED-FNN: A New Deep Learning Algorithm to Detect Percentage of the Gait Cycle for Powered Prostheses
title_sort ed-fnn: a new deep learning algorithm to detect percentage of the gait cycle for powered prostheses
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6068484/
https://www.ncbi.nlm.nih.gov/pubmed/30041421
http://dx.doi.org/10.3390/s18072389
work_keys_str_mv AT vuhuongthithu edfnnanewdeeplearningalgorithmtodetectpercentageofthegaitcycleforpoweredprostheses
AT gomezfelipe edfnnanewdeeplearningalgorithmtodetectpercentageofthegaitcycleforpoweredprostheses
AT cherellepierre edfnnanewdeeplearningalgorithmtodetectpercentageofthegaitcycleforpoweredprostheses
AT lefeberdirk edfnnanewdeeplearningalgorithmtodetectpercentageofthegaitcycleforpoweredprostheses
AT noweann edfnnanewdeeplearningalgorithmtodetectpercentageofthegaitcycleforpoweredprostheses
AT vanderborghtbram edfnnanewdeeplearningalgorithmtodetectpercentageofthegaitcycleforpoweredprostheses