Cargando…
On the Determination of Uncertainty and Limit of Detection in Label-Free Biosensors
A significant amount of noteworthy articles reviewing different label-free biosensors are being published in the last years. Most of the times, the comparison among the different biosensors is limited by the procedure used of calculating the limit of detection and the measurement uncertainty. This a...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6068557/ https://www.ncbi.nlm.nih.gov/pubmed/29949904 http://dx.doi.org/10.3390/s18072038 |
_version_ | 1783343296428376064 |
---|---|
author | Lavín, Álvaro de Vicente, Jesús Holgado, Miguel Laguna, María F. Casquel, Rafael Santamaría, Beatriz Maigler, María Victoria Hernández, Ana L. Ramírez, Yolanda |
author_facet | Lavín, Álvaro de Vicente, Jesús Holgado, Miguel Laguna, María F. Casquel, Rafael Santamaría, Beatriz Maigler, María Victoria Hernández, Ana L. Ramírez, Yolanda |
author_sort | Lavín, Álvaro |
collection | PubMed |
description | A significant amount of noteworthy articles reviewing different label-free biosensors are being published in the last years. Most of the times, the comparison among the different biosensors is limited by the procedure used of calculating the limit of detection and the measurement uncertainty. This article clarifies and establishes a simple procedure to determine the calibration function and the uncertainty of the concentration measured at any point of the measuring interval of a generic label-free biosensor. The value of the limit of detection arises naturally from this model as the limit at which uncertainty tends when the concentration tends to zero. The need to provide additional information, such as the measurement interval and its linearity, among others, on the analytical systems and biosensor in addition to the detection limit is pointed out. Finally, the model is applied to curves that are typically obtained in immunoassays and a discussion is made on the application validity of the model and its limitations. |
format | Online Article Text |
id | pubmed-6068557 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-60685572018-08-07 On the Determination of Uncertainty and Limit of Detection in Label-Free Biosensors Lavín, Álvaro de Vicente, Jesús Holgado, Miguel Laguna, María F. Casquel, Rafael Santamaría, Beatriz Maigler, María Victoria Hernández, Ana L. Ramírez, Yolanda Sensors (Basel) Review A significant amount of noteworthy articles reviewing different label-free biosensors are being published in the last years. Most of the times, the comparison among the different biosensors is limited by the procedure used of calculating the limit of detection and the measurement uncertainty. This article clarifies and establishes a simple procedure to determine the calibration function and the uncertainty of the concentration measured at any point of the measuring interval of a generic label-free biosensor. The value of the limit of detection arises naturally from this model as the limit at which uncertainty tends when the concentration tends to zero. The need to provide additional information, such as the measurement interval and its linearity, among others, on the analytical systems and biosensor in addition to the detection limit is pointed out. Finally, the model is applied to curves that are typically obtained in immunoassays and a discussion is made on the application validity of the model and its limitations. MDPI 2018-06-26 /pmc/articles/PMC6068557/ /pubmed/29949904 http://dx.doi.org/10.3390/s18072038 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Review Lavín, Álvaro de Vicente, Jesús Holgado, Miguel Laguna, María F. Casquel, Rafael Santamaría, Beatriz Maigler, María Victoria Hernández, Ana L. Ramírez, Yolanda On the Determination of Uncertainty and Limit of Detection in Label-Free Biosensors |
title | On the Determination of Uncertainty and Limit of Detection in Label-Free Biosensors |
title_full | On the Determination of Uncertainty and Limit of Detection in Label-Free Biosensors |
title_fullStr | On the Determination of Uncertainty and Limit of Detection in Label-Free Biosensors |
title_full_unstemmed | On the Determination of Uncertainty and Limit of Detection in Label-Free Biosensors |
title_short | On the Determination of Uncertainty and Limit of Detection in Label-Free Biosensors |
title_sort | on the determination of uncertainty and limit of detection in label-free biosensors |
topic | Review |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6068557/ https://www.ncbi.nlm.nih.gov/pubmed/29949904 http://dx.doi.org/10.3390/s18072038 |
work_keys_str_mv | AT lavinalvaro onthedeterminationofuncertaintyandlimitofdetectioninlabelfreebiosensors AT devicentejesus onthedeterminationofuncertaintyandlimitofdetectioninlabelfreebiosensors AT holgadomiguel onthedeterminationofuncertaintyandlimitofdetectioninlabelfreebiosensors AT lagunamariaf onthedeterminationofuncertaintyandlimitofdetectioninlabelfreebiosensors AT casquelrafael onthedeterminationofuncertaintyandlimitofdetectioninlabelfreebiosensors AT santamariabeatriz onthedeterminationofuncertaintyandlimitofdetectioninlabelfreebiosensors AT maiglermariavictoria onthedeterminationofuncertaintyandlimitofdetectioninlabelfreebiosensors AT hernandezanal onthedeterminationofuncertaintyandlimitofdetectioninlabelfreebiosensors AT ramirezyolanda onthedeterminationofuncertaintyandlimitofdetectioninlabelfreebiosensors |