Cargando…

On the Determination of Uncertainty and Limit of Detection in Label-Free Biosensors

A significant amount of noteworthy articles reviewing different label-free biosensors are being published in the last years. Most of the times, the comparison among the different biosensors is limited by the procedure used of calculating the limit of detection and the measurement uncertainty. This a...

Descripción completa

Detalles Bibliográficos
Autores principales: Lavín, Álvaro, de Vicente, Jesús, Holgado, Miguel, Laguna, María F., Casquel, Rafael, Santamaría, Beatriz, Maigler, María Victoria, Hernández, Ana L., Ramírez, Yolanda
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6068557/
https://www.ncbi.nlm.nih.gov/pubmed/29949904
http://dx.doi.org/10.3390/s18072038
_version_ 1783343296428376064
author Lavín, Álvaro
de Vicente, Jesús
Holgado, Miguel
Laguna, María F.
Casquel, Rafael
Santamaría, Beatriz
Maigler, María Victoria
Hernández, Ana L.
Ramírez, Yolanda
author_facet Lavín, Álvaro
de Vicente, Jesús
Holgado, Miguel
Laguna, María F.
Casquel, Rafael
Santamaría, Beatriz
Maigler, María Victoria
Hernández, Ana L.
Ramírez, Yolanda
author_sort Lavín, Álvaro
collection PubMed
description A significant amount of noteworthy articles reviewing different label-free biosensors are being published in the last years. Most of the times, the comparison among the different biosensors is limited by the procedure used of calculating the limit of detection and the measurement uncertainty. This article clarifies and establishes a simple procedure to determine the calibration function and the uncertainty of the concentration measured at any point of the measuring interval of a generic label-free biosensor. The value of the limit of detection arises naturally from this model as the limit at which uncertainty tends when the concentration tends to zero. The need to provide additional information, such as the measurement interval and its linearity, among others, on the analytical systems and biosensor in addition to the detection limit is pointed out. Finally, the model is applied to curves that are typically obtained in immunoassays and a discussion is made on the application validity of the model and its limitations.
format Online
Article
Text
id pubmed-6068557
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-60685572018-08-07 On the Determination of Uncertainty and Limit of Detection in Label-Free Biosensors Lavín, Álvaro de Vicente, Jesús Holgado, Miguel Laguna, María F. Casquel, Rafael Santamaría, Beatriz Maigler, María Victoria Hernández, Ana L. Ramírez, Yolanda Sensors (Basel) Review A significant amount of noteworthy articles reviewing different label-free biosensors are being published in the last years. Most of the times, the comparison among the different biosensors is limited by the procedure used of calculating the limit of detection and the measurement uncertainty. This article clarifies and establishes a simple procedure to determine the calibration function and the uncertainty of the concentration measured at any point of the measuring interval of a generic label-free biosensor. The value of the limit of detection arises naturally from this model as the limit at which uncertainty tends when the concentration tends to zero. The need to provide additional information, such as the measurement interval and its linearity, among others, on the analytical systems and biosensor in addition to the detection limit is pointed out. Finally, the model is applied to curves that are typically obtained in immunoassays and a discussion is made on the application validity of the model and its limitations. MDPI 2018-06-26 /pmc/articles/PMC6068557/ /pubmed/29949904 http://dx.doi.org/10.3390/s18072038 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Review
Lavín, Álvaro
de Vicente, Jesús
Holgado, Miguel
Laguna, María F.
Casquel, Rafael
Santamaría, Beatriz
Maigler, María Victoria
Hernández, Ana L.
Ramírez, Yolanda
On the Determination of Uncertainty and Limit of Detection in Label-Free Biosensors
title On the Determination of Uncertainty and Limit of Detection in Label-Free Biosensors
title_full On the Determination of Uncertainty and Limit of Detection in Label-Free Biosensors
title_fullStr On the Determination of Uncertainty and Limit of Detection in Label-Free Biosensors
title_full_unstemmed On the Determination of Uncertainty and Limit of Detection in Label-Free Biosensors
title_short On the Determination of Uncertainty and Limit of Detection in Label-Free Biosensors
title_sort on the determination of uncertainty and limit of detection in label-free biosensors
topic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6068557/
https://www.ncbi.nlm.nih.gov/pubmed/29949904
http://dx.doi.org/10.3390/s18072038
work_keys_str_mv AT lavinalvaro onthedeterminationofuncertaintyandlimitofdetectioninlabelfreebiosensors
AT devicentejesus onthedeterminationofuncertaintyandlimitofdetectioninlabelfreebiosensors
AT holgadomiguel onthedeterminationofuncertaintyandlimitofdetectioninlabelfreebiosensors
AT lagunamariaf onthedeterminationofuncertaintyandlimitofdetectioninlabelfreebiosensors
AT casquelrafael onthedeterminationofuncertaintyandlimitofdetectioninlabelfreebiosensors
AT santamariabeatriz onthedeterminationofuncertaintyandlimitofdetectioninlabelfreebiosensors
AT maiglermariavictoria onthedeterminationofuncertaintyandlimitofdetectioninlabelfreebiosensors
AT hernandezanal onthedeterminationofuncertaintyandlimitofdetectioninlabelfreebiosensors
AT ramirezyolanda onthedeterminationofuncertaintyandlimitofdetectioninlabelfreebiosensors