Monitoring System Analysis for Evaluating a Building’s Envelope Energy Performance through Estimation of Its Heat Loss Coefficient

The present article investigates the question of building energy monitoring systems used for data collection to estimate the Heat Loss Coefficient (HLC) with existing methods, in order to determine the Thermal Envelope Performance (TEP) of a building. The data requirements of HLC estimation methods...

Descripción completa

Detalles Bibliográficos
Autores principales: Giraldo-Soto, Catalina, Erkoreka, Aitor, Mora, Laurent, Uriarte, Irati, del Portillo, Luis Alfonso
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6068572/
https://www.ncbi.nlm.nih.gov/pubmed/30036997
http://dx.doi.org/10.3390/s18072360
_version_ 1783343299935862784
author Giraldo-Soto, Catalina
Erkoreka, Aitor
Mora, Laurent
Uriarte, Irati
del Portillo, Luis Alfonso
author_facet Giraldo-Soto, Catalina
Erkoreka, Aitor
Mora, Laurent
Uriarte, Irati
del Portillo, Luis Alfonso
author_sort Giraldo-Soto, Catalina
collection PubMed
description The present article investigates the question of building energy monitoring systems used for data collection to estimate the Heat Loss Coefficient (HLC) with existing methods, in order to determine the Thermal Envelope Performance (TEP) of a building. The data requirements of HLC estimation methods are related to commonly used methods for fault detection, calibration, and supervision of energy monitoring systems in buildings. Based on an extended review of experimental tests to estimate the HLC undertaken since 1978, qualitative and quantitative analyses of the Monitoring and Controlling System (MCS) specifications have been carried out. The results show that no Fault Detection and Diagnosis (FDD) methods have been implemented in the reviewed literature. Furthermore, it was not possible to identify a trend of technology type used in sensors, hardware, software, and communication protocols, because a high percentage of the reviewed experimental tests do not specify the model, technical characteristics, or selection criteria of the implemented MCSs. Although most actual Building Automation Systems (BAS) may measure the required parameters, further research is still needed to ensure that these data are accurate enough to rigorously apply HLC estimation methods.
format Online
Article
Text
id pubmed-6068572
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-60685722018-08-07 Monitoring System Analysis for Evaluating a Building’s Envelope Energy Performance through Estimation of Its Heat Loss Coefficient Giraldo-Soto, Catalina Erkoreka, Aitor Mora, Laurent Uriarte, Irati del Portillo, Luis Alfonso Sensors (Basel) Review The present article investigates the question of building energy monitoring systems used for data collection to estimate the Heat Loss Coefficient (HLC) with existing methods, in order to determine the Thermal Envelope Performance (TEP) of a building. The data requirements of HLC estimation methods are related to commonly used methods for fault detection, calibration, and supervision of energy monitoring systems in buildings. Based on an extended review of experimental tests to estimate the HLC undertaken since 1978, qualitative and quantitative analyses of the Monitoring and Controlling System (MCS) specifications have been carried out. The results show that no Fault Detection and Diagnosis (FDD) methods have been implemented in the reviewed literature. Furthermore, it was not possible to identify a trend of technology type used in sensors, hardware, software, and communication protocols, because a high percentage of the reviewed experimental tests do not specify the model, technical characteristics, or selection criteria of the implemented MCSs. Although most actual Building Automation Systems (BAS) may measure the required parameters, further research is still needed to ensure that these data are accurate enough to rigorously apply HLC estimation methods. MDPI 2018-07-20 /pmc/articles/PMC6068572/ /pubmed/30036997 http://dx.doi.org/10.3390/s18072360 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Review
Giraldo-Soto, Catalina
Erkoreka, Aitor
Mora, Laurent
Uriarte, Irati
del Portillo, Luis Alfonso
Monitoring System Analysis for Evaluating a Building’s Envelope Energy Performance through Estimation of Its Heat Loss Coefficient
title Monitoring System Analysis for Evaluating a Building’s Envelope Energy Performance through Estimation of Its Heat Loss Coefficient
title_full Monitoring System Analysis for Evaluating a Building’s Envelope Energy Performance through Estimation of Its Heat Loss Coefficient
title_fullStr Monitoring System Analysis for Evaluating a Building’s Envelope Energy Performance through Estimation of Its Heat Loss Coefficient
title_full_unstemmed Monitoring System Analysis for Evaluating a Building’s Envelope Energy Performance through Estimation of Its Heat Loss Coefficient
title_short Monitoring System Analysis for Evaluating a Building’s Envelope Energy Performance through Estimation of Its Heat Loss Coefficient
title_sort monitoring system analysis for evaluating a building’s envelope energy performance through estimation of its heat loss coefficient
topic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6068572/
https://www.ncbi.nlm.nih.gov/pubmed/30036997
http://dx.doi.org/10.3390/s18072360
work_keys_str_mv AT giraldosotocatalina monitoringsystemanalysisforevaluatingabuildingsenvelopeenergyperformancethroughestimationofitsheatlosscoefficient
AT erkorekaaitor monitoringsystemanalysisforevaluatingabuildingsenvelopeenergyperformancethroughestimationofitsheatlosscoefficient
AT moralaurent monitoringsystemanalysisforevaluatingabuildingsenvelopeenergyperformancethroughestimationofitsheatlosscoefficient
AT uriarteirati monitoringsystemanalysisforevaluatingabuildingsenvelopeenergyperformancethroughestimationofitsheatlosscoefficient
AT delportilloluisalfonso monitoringsystemanalysisforevaluatingabuildingsenvelopeenergyperformancethroughestimationofitsheatlosscoefficient