Cargando…

Validity, Test-Retest Reliability and Long-Term Stability of Magnetometer Free Inertial Sensor Based 3D Joint Kinematics

The present study investigates an algorithm for the calculation of 3D joint angles based on inertial measurement units (IMUs), omitting magnetometer data. Validity, test-retest reliability, and long-term stability are evaluated in reference to an optical motion capture (OMC) system. Twenty-eight hea...

Descripción completa

Detalles Bibliográficos
Autores principales: Teufl, Wolfgang, Miezal, Markus, Taetz, Bertram, Fröhlich, Michael, Bleser, Gabriele
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6068643/
https://www.ncbi.nlm.nih.gov/pubmed/29933568
http://dx.doi.org/10.3390/s18071980
_version_ 1783343316484489216
author Teufl, Wolfgang
Miezal, Markus
Taetz, Bertram
Fröhlich, Michael
Bleser, Gabriele
author_facet Teufl, Wolfgang
Miezal, Markus
Taetz, Bertram
Fröhlich, Michael
Bleser, Gabriele
author_sort Teufl, Wolfgang
collection PubMed
description The present study investigates an algorithm for the calculation of 3D joint angles based on inertial measurement units (IMUs), omitting magnetometer data. Validity, test-retest reliability, and long-term stability are evaluated in reference to an optical motion capture (OMC) system. Twenty-eight healthy subjects performed a 6 min walk test. Three-dimensional joint kinematics of the lower extremity was recorded simultaneously by means of seven IMUs and an OptiTrack OMC system. To evaluate the performance, the root mean squared error (RMSE), mean range of motion error (ROME), coefficient of multiple correlations (CMC), Bland-Altman (BA) analysis, and intraclass correlation coefficient (ICC) were calculated. For all joints, the RMSE was lower than 2.40°, and the ROME was lower than 1.60°. The CMC revealed good to excellent waveform similarity. Reliability was moderate to excellent with ICC values of 0.52–0.99 for all joints. Error measures did not increase over time. When considering soft tissue artefacts, RMSE and ROME increased by an average of 2.2° ± 1.5° and 2.9° ± 1.7°. This study revealed an excellent correspondence of a magnetometer-free IMU system with an OMC system when excluding soft tissue artefacts.
format Online
Article
Text
id pubmed-6068643
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-60686432018-08-07 Validity, Test-Retest Reliability and Long-Term Stability of Magnetometer Free Inertial Sensor Based 3D Joint Kinematics Teufl, Wolfgang Miezal, Markus Taetz, Bertram Fröhlich, Michael Bleser, Gabriele Sensors (Basel) Article The present study investigates an algorithm for the calculation of 3D joint angles based on inertial measurement units (IMUs), omitting magnetometer data. Validity, test-retest reliability, and long-term stability are evaluated in reference to an optical motion capture (OMC) system. Twenty-eight healthy subjects performed a 6 min walk test. Three-dimensional joint kinematics of the lower extremity was recorded simultaneously by means of seven IMUs and an OptiTrack OMC system. To evaluate the performance, the root mean squared error (RMSE), mean range of motion error (ROME), coefficient of multiple correlations (CMC), Bland-Altman (BA) analysis, and intraclass correlation coefficient (ICC) were calculated. For all joints, the RMSE was lower than 2.40°, and the ROME was lower than 1.60°. The CMC revealed good to excellent waveform similarity. Reliability was moderate to excellent with ICC values of 0.52–0.99 for all joints. Error measures did not increase over time. When considering soft tissue artefacts, RMSE and ROME increased by an average of 2.2° ± 1.5° and 2.9° ± 1.7°. This study revealed an excellent correspondence of a magnetometer-free IMU system with an OMC system when excluding soft tissue artefacts. MDPI 2018-06-21 /pmc/articles/PMC6068643/ /pubmed/29933568 http://dx.doi.org/10.3390/s18071980 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Teufl, Wolfgang
Miezal, Markus
Taetz, Bertram
Fröhlich, Michael
Bleser, Gabriele
Validity, Test-Retest Reliability and Long-Term Stability of Magnetometer Free Inertial Sensor Based 3D Joint Kinematics
title Validity, Test-Retest Reliability and Long-Term Stability of Magnetometer Free Inertial Sensor Based 3D Joint Kinematics
title_full Validity, Test-Retest Reliability and Long-Term Stability of Magnetometer Free Inertial Sensor Based 3D Joint Kinematics
title_fullStr Validity, Test-Retest Reliability and Long-Term Stability of Magnetometer Free Inertial Sensor Based 3D Joint Kinematics
title_full_unstemmed Validity, Test-Retest Reliability and Long-Term Stability of Magnetometer Free Inertial Sensor Based 3D Joint Kinematics
title_short Validity, Test-Retest Reliability and Long-Term Stability of Magnetometer Free Inertial Sensor Based 3D Joint Kinematics
title_sort validity, test-retest reliability and long-term stability of magnetometer free inertial sensor based 3d joint kinematics
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6068643/
https://www.ncbi.nlm.nih.gov/pubmed/29933568
http://dx.doi.org/10.3390/s18071980
work_keys_str_mv AT teuflwolfgang validitytestretestreliabilityandlongtermstabilityofmagnetometerfreeinertialsensorbased3djointkinematics
AT miezalmarkus validitytestretestreliabilityandlongtermstabilityofmagnetometerfreeinertialsensorbased3djointkinematics
AT taetzbertram validitytestretestreliabilityandlongtermstabilityofmagnetometerfreeinertialsensorbased3djointkinematics
AT frohlichmichael validitytestretestreliabilityandlongtermstabilityofmagnetometerfreeinertialsensorbased3djointkinematics
AT blesergabriele validitytestretestreliabilityandlongtermstabilityofmagnetometerfreeinertialsensorbased3djointkinematics