Cargando…
Validity, Test-Retest Reliability and Long-Term Stability of Magnetometer Free Inertial Sensor Based 3D Joint Kinematics
The present study investigates an algorithm for the calculation of 3D joint angles based on inertial measurement units (IMUs), omitting magnetometer data. Validity, test-retest reliability, and long-term stability are evaluated in reference to an optical motion capture (OMC) system. Twenty-eight hea...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6068643/ https://www.ncbi.nlm.nih.gov/pubmed/29933568 http://dx.doi.org/10.3390/s18071980 |
_version_ | 1783343316484489216 |
---|---|
author | Teufl, Wolfgang Miezal, Markus Taetz, Bertram Fröhlich, Michael Bleser, Gabriele |
author_facet | Teufl, Wolfgang Miezal, Markus Taetz, Bertram Fröhlich, Michael Bleser, Gabriele |
author_sort | Teufl, Wolfgang |
collection | PubMed |
description | The present study investigates an algorithm for the calculation of 3D joint angles based on inertial measurement units (IMUs), omitting magnetometer data. Validity, test-retest reliability, and long-term stability are evaluated in reference to an optical motion capture (OMC) system. Twenty-eight healthy subjects performed a 6 min walk test. Three-dimensional joint kinematics of the lower extremity was recorded simultaneously by means of seven IMUs and an OptiTrack OMC system. To evaluate the performance, the root mean squared error (RMSE), mean range of motion error (ROME), coefficient of multiple correlations (CMC), Bland-Altman (BA) analysis, and intraclass correlation coefficient (ICC) were calculated. For all joints, the RMSE was lower than 2.40°, and the ROME was lower than 1.60°. The CMC revealed good to excellent waveform similarity. Reliability was moderate to excellent with ICC values of 0.52–0.99 for all joints. Error measures did not increase over time. When considering soft tissue artefacts, RMSE and ROME increased by an average of 2.2° ± 1.5° and 2.9° ± 1.7°. This study revealed an excellent correspondence of a magnetometer-free IMU system with an OMC system when excluding soft tissue artefacts. |
format | Online Article Text |
id | pubmed-6068643 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-60686432018-08-07 Validity, Test-Retest Reliability and Long-Term Stability of Magnetometer Free Inertial Sensor Based 3D Joint Kinematics Teufl, Wolfgang Miezal, Markus Taetz, Bertram Fröhlich, Michael Bleser, Gabriele Sensors (Basel) Article The present study investigates an algorithm for the calculation of 3D joint angles based on inertial measurement units (IMUs), omitting magnetometer data. Validity, test-retest reliability, and long-term stability are evaluated in reference to an optical motion capture (OMC) system. Twenty-eight healthy subjects performed a 6 min walk test. Three-dimensional joint kinematics of the lower extremity was recorded simultaneously by means of seven IMUs and an OptiTrack OMC system. To evaluate the performance, the root mean squared error (RMSE), mean range of motion error (ROME), coefficient of multiple correlations (CMC), Bland-Altman (BA) analysis, and intraclass correlation coefficient (ICC) were calculated. For all joints, the RMSE was lower than 2.40°, and the ROME was lower than 1.60°. The CMC revealed good to excellent waveform similarity. Reliability was moderate to excellent with ICC values of 0.52–0.99 for all joints. Error measures did not increase over time. When considering soft tissue artefacts, RMSE and ROME increased by an average of 2.2° ± 1.5° and 2.9° ± 1.7°. This study revealed an excellent correspondence of a magnetometer-free IMU system with an OMC system when excluding soft tissue artefacts. MDPI 2018-06-21 /pmc/articles/PMC6068643/ /pubmed/29933568 http://dx.doi.org/10.3390/s18071980 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Teufl, Wolfgang Miezal, Markus Taetz, Bertram Fröhlich, Michael Bleser, Gabriele Validity, Test-Retest Reliability and Long-Term Stability of Magnetometer Free Inertial Sensor Based 3D Joint Kinematics |
title | Validity, Test-Retest Reliability and Long-Term Stability of Magnetometer Free Inertial Sensor Based 3D Joint Kinematics |
title_full | Validity, Test-Retest Reliability and Long-Term Stability of Magnetometer Free Inertial Sensor Based 3D Joint Kinematics |
title_fullStr | Validity, Test-Retest Reliability and Long-Term Stability of Magnetometer Free Inertial Sensor Based 3D Joint Kinematics |
title_full_unstemmed | Validity, Test-Retest Reliability and Long-Term Stability of Magnetometer Free Inertial Sensor Based 3D Joint Kinematics |
title_short | Validity, Test-Retest Reliability and Long-Term Stability of Magnetometer Free Inertial Sensor Based 3D Joint Kinematics |
title_sort | validity, test-retest reliability and long-term stability of magnetometer free inertial sensor based 3d joint kinematics |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6068643/ https://www.ncbi.nlm.nih.gov/pubmed/29933568 http://dx.doi.org/10.3390/s18071980 |
work_keys_str_mv | AT teuflwolfgang validitytestretestreliabilityandlongtermstabilityofmagnetometerfreeinertialsensorbased3djointkinematics AT miezalmarkus validitytestretestreliabilityandlongtermstabilityofmagnetometerfreeinertialsensorbased3djointkinematics AT taetzbertram validitytestretestreliabilityandlongtermstabilityofmagnetometerfreeinertialsensorbased3djointkinematics AT frohlichmichael validitytestretestreliabilityandlongtermstabilityofmagnetometerfreeinertialsensorbased3djointkinematics AT blesergabriele validitytestretestreliabilityandlongtermstabilityofmagnetometerfreeinertialsensorbased3djointkinematics |