Cargando…

Nitric Oxide Analysis Down to ppt Levels by Optical-Feedback Cavity-Enhanced Absorption Spectroscopy

Monitoring nitric oxide at the trace level is required in a large range of applications. We report on a trace gas analyzer optimized for nitric oxide measurements by Optical Feedback Cavity Enhanced Absorption Spectroscopy with an interband cascade laser at 5.3 µm. The short response time of the ins...

Descripción completa

Detalles Bibliográficos
Autores principales: Richard, Lucile, Romanini, Daniele, Ventrillard, Irène
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6068816/
https://www.ncbi.nlm.nih.gov/pubmed/29932103
http://dx.doi.org/10.3390/s18071997
_version_ 1783343353016877056
author Richard, Lucile
Romanini, Daniele
Ventrillard, Irène
author_facet Richard, Lucile
Romanini, Daniele
Ventrillard, Irène
author_sort Richard, Lucile
collection PubMed
description Monitoring nitric oxide at the trace level is required in a large range of applications. We report on a trace gas analyzer optimized for nitric oxide measurements by Optical Feedback Cavity Enhanced Absorption Spectroscopy with an interband cascade laser at 5.3 µm. The short response time of the instrument allows for reaching the level of 50 ppt in only 180 ms. Its stability enables averaging up to 12 min to reach a detection limit of 0.9 ppt. Absolute concentration calibration requires to account for the optical saturation effect that results from the intense absorption line intensity addressed here, in the mid infrared region, in contrast to instruments that are operating in the near infrared region.
format Online
Article
Text
id pubmed-6068816
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-60688162018-08-07 Nitric Oxide Analysis Down to ppt Levels by Optical-Feedback Cavity-Enhanced Absorption Spectroscopy Richard, Lucile Romanini, Daniele Ventrillard, Irène Sensors (Basel) Article Monitoring nitric oxide at the trace level is required in a large range of applications. We report on a trace gas analyzer optimized for nitric oxide measurements by Optical Feedback Cavity Enhanced Absorption Spectroscopy with an interband cascade laser at 5.3 µm. The short response time of the instrument allows for reaching the level of 50 ppt in only 180 ms. Its stability enables averaging up to 12 min to reach a detection limit of 0.9 ppt. Absolute concentration calibration requires to account for the optical saturation effect that results from the intense absorption line intensity addressed here, in the mid infrared region, in contrast to instruments that are operating in the near infrared region. MDPI 2018-06-22 /pmc/articles/PMC6068816/ /pubmed/29932103 http://dx.doi.org/10.3390/s18071997 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Richard, Lucile
Romanini, Daniele
Ventrillard, Irène
Nitric Oxide Analysis Down to ppt Levels by Optical-Feedback Cavity-Enhanced Absorption Spectroscopy
title Nitric Oxide Analysis Down to ppt Levels by Optical-Feedback Cavity-Enhanced Absorption Spectroscopy
title_full Nitric Oxide Analysis Down to ppt Levels by Optical-Feedback Cavity-Enhanced Absorption Spectroscopy
title_fullStr Nitric Oxide Analysis Down to ppt Levels by Optical-Feedback Cavity-Enhanced Absorption Spectroscopy
title_full_unstemmed Nitric Oxide Analysis Down to ppt Levels by Optical-Feedback Cavity-Enhanced Absorption Spectroscopy
title_short Nitric Oxide Analysis Down to ppt Levels by Optical-Feedback Cavity-Enhanced Absorption Spectroscopy
title_sort nitric oxide analysis down to ppt levels by optical-feedback cavity-enhanced absorption spectroscopy
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6068816/
https://www.ncbi.nlm.nih.gov/pubmed/29932103
http://dx.doi.org/10.3390/s18071997
work_keys_str_mv AT richardlucile nitricoxideanalysisdowntopptlevelsbyopticalfeedbackcavityenhancedabsorptionspectroscopy
AT romaninidaniele nitricoxideanalysisdowntopptlevelsbyopticalfeedbackcavityenhancedabsorptionspectroscopy
AT ventrillardirene nitricoxideanalysisdowntopptlevelsbyopticalfeedbackcavityenhancedabsorptionspectroscopy