Cargando…

A 10-Bit 300 kS/s Reference-Voltage Regulator Free SAR ADC for Wireless-Powered Implantable Medical Devices

This paper presents a reference-voltage regulator free successive-approximation-register analog-to-digital converters (SAR ADC) with self-timed pre-charging for wireless-powered implantable medical devices. Assisted by a self-timed pre-charging technique, the proposed SAR ADC eliminates the need for...

Descripción completa

Detalles Bibliográficos
Autores principales: Yang, Yongkui, Zhou, Jun, Liu, Xin, Goh, Wang Ling
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6068884/
https://www.ncbi.nlm.nih.gov/pubmed/29970814
http://dx.doi.org/10.3390/s18072131
_version_ 1783343369235202048
author Yang, Yongkui
Zhou, Jun
Liu, Xin
Goh, Wang Ling
author_facet Yang, Yongkui
Zhou, Jun
Liu, Xin
Goh, Wang Ling
author_sort Yang, Yongkui
collection PubMed
description This paper presents a reference-voltage regulator free successive-approximation-register analog-to-digital converters (SAR ADC) with self-timed pre-charging for wireless-powered implantable medical devices. Assisted by a self-timed pre-charging technique, the proposed SAR ADC eliminates the need for a power-hungry reference-voltage regulator and area-consuming decoupling capacitor while maintaining insensitivity to the supply voltage fluctuation. Fabricated with a 0.18-µm complementary metal–oxide–semiconductor (CMOS) technology, the proposed SAR ADC achieves a Signal To Noise And Distortion Ratio (SNDR) of 53.32 dB operating at 0.8 V with a supply voltage fluctuation of 50 mV(pp) and consumes a total power of 2.72 µW at a sampling rate of 300 kS/s. Including the self-timed pre-charging circuits, the total figure-of-merit (FOM) is 23.9 fJ/conversion-step and the total area occupied is 0.105 mm(2).
format Online
Article
Text
id pubmed-6068884
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-60688842018-08-07 A 10-Bit 300 kS/s Reference-Voltage Regulator Free SAR ADC for Wireless-Powered Implantable Medical Devices Yang, Yongkui Zhou, Jun Liu, Xin Goh, Wang Ling Sensors (Basel) Article This paper presents a reference-voltage regulator free successive-approximation-register analog-to-digital converters (SAR ADC) with self-timed pre-charging for wireless-powered implantable medical devices. Assisted by a self-timed pre-charging technique, the proposed SAR ADC eliminates the need for a power-hungry reference-voltage regulator and area-consuming decoupling capacitor while maintaining insensitivity to the supply voltage fluctuation. Fabricated with a 0.18-µm complementary metal–oxide–semiconductor (CMOS) technology, the proposed SAR ADC achieves a Signal To Noise And Distortion Ratio (SNDR) of 53.32 dB operating at 0.8 V with a supply voltage fluctuation of 50 mV(pp) and consumes a total power of 2.72 µW at a sampling rate of 300 kS/s. Including the self-timed pre-charging circuits, the total figure-of-merit (FOM) is 23.9 fJ/conversion-step and the total area occupied is 0.105 mm(2). MDPI 2018-07-03 /pmc/articles/PMC6068884/ /pubmed/29970814 http://dx.doi.org/10.3390/s18072131 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Yang, Yongkui
Zhou, Jun
Liu, Xin
Goh, Wang Ling
A 10-Bit 300 kS/s Reference-Voltage Regulator Free SAR ADC for Wireless-Powered Implantable Medical Devices
title A 10-Bit 300 kS/s Reference-Voltage Regulator Free SAR ADC for Wireless-Powered Implantable Medical Devices
title_full A 10-Bit 300 kS/s Reference-Voltage Regulator Free SAR ADC for Wireless-Powered Implantable Medical Devices
title_fullStr A 10-Bit 300 kS/s Reference-Voltage Regulator Free SAR ADC for Wireless-Powered Implantable Medical Devices
title_full_unstemmed A 10-Bit 300 kS/s Reference-Voltage Regulator Free SAR ADC for Wireless-Powered Implantable Medical Devices
title_short A 10-Bit 300 kS/s Reference-Voltage Regulator Free SAR ADC for Wireless-Powered Implantable Medical Devices
title_sort 10-bit 300 ks/s reference-voltage regulator free sar adc for wireless-powered implantable medical devices
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6068884/
https://www.ncbi.nlm.nih.gov/pubmed/29970814
http://dx.doi.org/10.3390/s18072131
work_keys_str_mv AT yangyongkui a10bit300kssreferencevoltageregulatorfreesaradcforwirelesspoweredimplantablemedicaldevices
AT zhoujun a10bit300kssreferencevoltageregulatorfreesaradcforwirelesspoweredimplantablemedicaldevices
AT liuxin a10bit300kssreferencevoltageregulatorfreesaradcforwirelesspoweredimplantablemedicaldevices
AT gohwangling a10bit300kssreferencevoltageregulatorfreesaradcforwirelesspoweredimplantablemedicaldevices
AT yangyongkui 10bit300kssreferencevoltageregulatorfreesaradcforwirelesspoweredimplantablemedicaldevices
AT zhoujun 10bit300kssreferencevoltageregulatorfreesaradcforwirelesspoweredimplantablemedicaldevices
AT liuxin 10bit300kssreferencevoltageregulatorfreesaradcforwirelesspoweredimplantablemedicaldevices
AT gohwangling 10bit300kssreferencevoltageregulatorfreesaradcforwirelesspoweredimplantablemedicaldevices