Cargando…
Optical-Spectrometry-Based Method for Immunosuppressant Medicine Level Detection in Aqueous Solutions
In this paper, an investigation into detecting immunosuppressive medicine in aqueous solutions using a spectrometry-based technique is described. Using optical transmissive spectrometry, absorbance measurements in the spectra range from 250 nm to 1000 nm were carried out for different cyclosporine A...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6068911/ https://www.ncbi.nlm.nih.gov/pubmed/29932121 http://dx.doi.org/10.3390/s18072001 |
_version_ | 1783343375588524032 |
---|---|
author | Marzejon, Marcin Kosowska, Monika Majchrowicz, Daria Bułło-Piontecka, Barbara Wąsowicz, Michał Jędrzejewska-Szczerska, Małgorzata |
author_facet | Marzejon, Marcin Kosowska, Monika Majchrowicz, Daria Bułło-Piontecka, Barbara Wąsowicz, Michał Jędrzejewska-Szczerska, Małgorzata |
author_sort | Marzejon, Marcin |
collection | PubMed |
description | In this paper, an investigation into detecting immunosuppressive medicine in aqueous solutions using a spectrometry-based technique is described. Using optical transmissive spectrometry, absorbance measurements in the spectra range from 250 nm to 1000 nm were carried out for different cyclosporine A (CsA) concentrations in aqueous solutions. The experiment was conducted for samples both with and without interferent substances—glucose and sodium chloride. Using a dedicated algorithm, the measured data was analyzed and a high correlation coefficient R(2) = 0.8647 was achieved. The experiment showed that the described technique allowed for the detection of various CsA concentration levels in a selective, label-free and simple way. This method could be used in medicine, veterinary medicine and laboratory diagnostics. |
format | Online Article Text |
id | pubmed-6068911 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-60689112018-08-07 Optical-Spectrometry-Based Method for Immunosuppressant Medicine Level Detection in Aqueous Solutions Marzejon, Marcin Kosowska, Monika Majchrowicz, Daria Bułło-Piontecka, Barbara Wąsowicz, Michał Jędrzejewska-Szczerska, Małgorzata Sensors (Basel) Article In this paper, an investigation into detecting immunosuppressive medicine in aqueous solutions using a spectrometry-based technique is described. Using optical transmissive spectrometry, absorbance measurements in the spectra range from 250 nm to 1000 nm were carried out for different cyclosporine A (CsA) concentrations in aqueous solutions. The experiment was conducted for samples both with and without interferent substances—glucose and sodium chloride. Using a dedicated algorithm, the measured data was analyzed and a high correlation coefficient R(2) = 0.8647 was achieved. The experiment showed that the described technique allowed for the detection of various CsA concentration levels in a selective, label-free and simple way. This method could be used in medicine, veterinary medicine and laboratory diagnostics. MDPI 2018-06-22 /pmc/articles/PMC6068911/ /pubmed/29932121 http://dx.doi.org/10.3390/s18072001 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Marzejon, Marcin Kosowska, Monika Majchrowicz, Daria Bułło-Piontecka, Barbara Wąsowicz, Michał Jędrzejewska-Szczerska, Małgorzata Optical-Spectrometry-Based Method for Immunosuppressant Medicine Level Detection in Aqueous Solutions |
title | Optical-Spectrometry-Based Method for Immunosuppressant Medicine Level Detection in Aqueous Solutions |
title_full | Optical-Spectrometry-Based Method for Immunosuppressant Medicine Level Detection in Aqueous Solutions |
title_fullStr | Optical-Spectrometry-Based Method for Immunosuppressant Medicine Level Detection in Aqueous Solutions |
title_full_unstemmed | Optical-Spectrometry-Based Method for Immunosuppressant Medicine Level Detection in Aqueous Solutions |
title_short | Optical-Spectrometry-Based Method for Immunosuppressant Medicine Level Detection in Aqueous Solutions |
title_sort | optical-spectrometry-based method for immunosuppressant medicine level detection in aqueous solutions |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6068911/ https://www.ncbi.nlm.nih.gov/pubmed/29932121 http://dx.doi.org/10.3390/s18072001 |
work_keys_str_mv | AT marzejonmarcin opticalspectrometrybasedmethodforimmunosuppressantmedicineleveldetectioninaqueoussolutions AT kosowskamonika opticalspectrometrybasedmethodforimmunosuppressantmedicineleveldetectioninaqueoussolutions AT majchrowiczdaria opticalspectrometrybasedmethodforimmunosuppressantmedicineleveldetectioninaqueoussolutions AT bułłopionteckabarbara opticalspectrometrybasedmethodforimmunosuppressantmedicineleveldetectioninaqueoussolutions AT wasowiczmichał opticalspectrometrybasedmethodforimmunosuppressantmedicineleveldetectioninaqueoussolutions AT jedrzejewskaszczerskamałgorzata opticalspectrometrybasedmethodforimmunosuppressantmedicineleveldetectioninaqueoussolutions |