Cargando…

Optical-Spectrometry-Based Method for Immunosuppressant Medicine Level Detection in Aqueous Solutions

In this paper, an investigation into detecting immunosuppressive medicine in aqueous solutions using a spectrometry-based technique is described. Using optical transmissive spectrometry, absorbance measurements in the spectra range from 250 nm to 1000 nm were carried out for different cyclosporine A...

Descripción completa

Detalles Bibliográficos
Autores principales: Marzejon, Marcin, Kosowska, Monika, Majchrowicz, Daria, Bułło-Piontecka, Barbara, Wąsowicz, Michał, Jędrzejewska-Szczerska, Małgorzata
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6068911/
https://www.ncbi.nlm.nih.gov/pubmed/29932121
http://dx.doi.org/10.3390/s18072001
_version_ 1783343375588524032
author Marzejon, Marcin
Kosowska, Monika
Majchrowicz, Daria
Bułło-Piontecka, Barbara
Wąsowicz, Michał
Jędrzejewska-Szczerska, Małgorzata
author_facet Marzejon, Marcin
Kosowska, Monika
Majchrowicz, Daria
Bułło-Piontecka, Barbara
Wąsowicz, Michał
Jędrzejewska-Szczerska, Małgorzata
author_sort Marzejon, Marcin
collection PubMed
description In this paper, an investigation into detecting immunosuppressive medicine in aqueous solutions using a spectrometry-based technique is described. Using optical transmissive spectrometry, absorbance measurements in the spectra range from 250 nm to 1000 nm were carried out for different cyclosporine A (CsA) concentrations in aqueous solutions. The experiment was conducted for samples both with and without interferent substances—glucose and sodium chloride. Using a dedicated algorithm, the measured data was analyzed and a high correlation coefficient R(2) = 0.8647 was achieved. The experiment showed that the described technique allowed for the detection of various CsA concentration levels in a selective, label-free and simple way. This method could be used in medicine, veterinary medicine and laboratory diagnostics.
format Online
Article
Text
id pubmed-6068911
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-60689112018-08-07 Optical-Spectrometry-Based Method for Immunosuppressant Medicine Level Detection in Aqueous Solutions Marzejon, Marcin Kosowska, Monika Majchrowicz, Daria Bułło-Piontecka, Barbara Wąsowicz, Michał Jędrzejewska-Szczerska, Małgorzata Sensors (Basel) Article In this paper, an investigation into detecting immunosuppressive medicine in aqueous solutions using a spectrometry-based technique is described. Using optical transmissive spectrometry, absorbance measurements in the spectra range from 250 nm to 1000 nm were carried out for different cyclosporine A (CsA) concentrations in aqueous solutions. The experiment was conducted for samples both with and without interferent substances—glucose and sodium chloride. Using a dedicated algorithm, the measured data was analyzed and a high correlation coefficient R(2) = 0.8647 was achieved. The experiment showed that the described technique allowed for the detection of various CsA concentration levels in a selective, label-free and simple way. This method could be used in medicine, veterinary medicine and laboratory diagnostics. MDPI 2018-06-22 /pmc/articles/PMC6068911/ /pubmed/29932121 http://dx.doi.org/10.3390/s18072001 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Marzejon, Marcin
Kosowska, Monika
Majchrowicz, Daria
Bułło-Piontecka, Barbara
Wąsowicz, Michał
Jędrzejewska-Szczerska, Małgorzata
Optical-Spectrometry-Based Method for Immunosuppressant Medicine Level Detection in Aqueous Solutions
title Optical-Spectrometry-Based Method for Immunosuppressant Medicine Level Detection in Aqueous Solutions
title_full Optical-Spectrometry-Based Method for Immunosuppressant Medicine Level Detection in Aqueous Solutions
title_fullStr Optical-Spectrometry-Based Method for Immunosuppressant Medicine Level Detection in Aqueous Solutions
title_full_unstemmed Optical-Spectrometry-Based Method for Immunosuppressant Medicine Level Detection in Aqueous Solutions
title_short Optical-Spectrometry-Based Method for Immunosuppressant Medicine Level Detection in Aqueous Solutions
title_sort optical-spectrometry-based method for immunosuppressant medicine level detection in aqueous solutions
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6068911/
https://www.ncbi.nlm.nih.gov/pubmed/29932121
http://dx.doi.org/10.3390/s18072001
work_keys_str_mv AT marzejonmarcin opticalspectrometrybasedmethodforimmunosuppressantmedicineleveldetectioninaqueoussolutions
AT kosowskamonika opticalspectrometrybasedmethodforimmunosuppressantmedicineleveldetectioninaqueoussolutions
AT majchrowiczdaria opticalspectrometrybasedmethodforimmunosuppressantmedicineleveldetectioninaqueoussolutions
AT bułłopionteckabarbara opticalspectrometrybasedmethodforimmunosuppressantmedicineleveldetectioninaqueoussolutions
AT wasowiczmichał opticalspectrometrybasedmethodforimmunosuppressantmedicineleveldetectioninaqueoussolutions
AT jedrzejewskaszczerskamałgorzata opticalspectrometrybasedmethodforimmunosuppressantmedicineleveldetectioninaqueoussolutions